ترغب بنشر مسار تعليمي؟ اضغط هنا

Design and Simulation of a high order mode cavity bunch length monitor

60   0   0.0 ( 0 )
 نشر من قبل Jiang Guo
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A new bunch length measurement method based on high order mode cavity was proposed. Operating the harmonic cavity at mode TM0n0 so that its radius could be chosen, in order to break the limitation of beam pipe radius. A two-cavity bunch length monitor for linac of positron source was designed. Operating frequency selection for different bunch time structure was discussed and calculation formula of bunch length was deducted. Fundamental harmonic cavity resonates at 2.856 GHz with mode TM010. Fifth harmonic cavity resonates at 14.28 GHz (fifth harmonic of the linac fundamental frequency 2.856 GHz) with mode TM020, which could provide larger radius. Each cavity equipped with a filter to suppress unwanted signal. A simulation measurement was conducted in CST Particle Studio for beam current from 100-300mA, bunch length from 5-10ps, calculation results shows a fairly high accuracy (better than 3%). Several cases were discussed.

قيم البحث

اقرأ أيضاً

Cavity Beam Length Monitor is beam length measurement detector metering ultra short bunch. We designed a RF front-end and make simulations to testify this has high signal-to-noise ratio ensuring beam length measurement precision.
Higher-order mode (HOM) based intra-cavity beam diagnostics has been proved effectively and conveniently in superconducting radio-frequency (SRF) accelerators. Our recent research shows that the beam harmonics in the bunch train excited HOM spectrum, which have much higher signal-to-noise ratio than the intrinsic HOM peaks, may also be useful for beam diagnostics. In this paper, we will present our study on bunch train excited HOMs, including the theoretic model and recent experiments carried out based on the DC-SRF photoinjector and SRF linac at Peking University.
High-bunch-charge photoemission electron-sources operating in a continuous wave (CW) mode are required for many advanced applications of particle accelerators, such as electron coolers for hadron beams, electron-ion colliders, and free-electron laser s (FELs). Superconducting RF (SRF) has several advantages over other electron-gun technologies in CW mode as it offers higher acceleration rate and potentially can generate higher bunch charges and average beam currents. A 112 MHz SRF electron photoinjector (gun) was developed at Brookhaven National Laboratory (BNL) to produce high-brightness and high-bunch-charge bunches for the Coherent electron Cooling Proof-of-Principle (CeC PoP) experiment. The gun utilizes a quarter-wave resonator (QWR) geometry for assuring beam dynamics, and uses high quantum efficiency (QE) multi-alkali photocathodes for generating electrons.
Realization of a short bunch beam by manipulating the longitudinal phase space distribution with a finite longitudinal dispersion following an off-crest accelera- tion is a widely used technique. The technique was applied in a compact test accelerato r of an energy-recovery linac scheme for compressing the bunch length at the return loop. A diagnostic system utilizing coherent transition radiation was developed for the beam tuning and for estimating the bunch length. By scanning the beam parameters, we experimentally found the best condition for the bunch compression. The RMS bunch length of 250+-50 fs was obtained at a bunch charge of 2 pC. This result confirmed the design and the tuning pro- cedure of the bunch compression operation for the future energy-recovery linac (ERL).
With electron beam durations down to femtoseconds and sub-femtoseconds achievable in current state-of-the-art accelerators, longitudinal bunch length diagnostics with resolution at the attosecond level are required. In this paper, we present such a n ovel measurement device which combines a high power laser modulator with an RF deflecting cavity in the orthogonal direction. While the laser applies a strong correlated angular modulation to a beam, the RF deflector ensures the full resolution of this streaking effect across the bunch hence recovering the temporal beam profile with sub-femtosecond resolution. Preliminary measurements to test the key components of this concept were carried out at the Accelerator Test Facility (ATF) at Brookhaven National Laboratory recently, the results of which are presented and discussed here. Moreover, a possible application of the technique for novel accelerator schemes is examined based on simulations with the particle-tracking code elegant and our beam profile reconstruction tool.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا