Beam optical design for high energy electron radiography experiment study based on THU LINAC

156   0   0.0 ( 0 )
 نشر من قبل Quantang Zhao
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A special beam line for high energy electron radiography is designed, including achromat and imaging systems. The requirement of the angle and position correction on the target from imaging system can be approximately realized by fine tuning the quadrupoles used in the achromat. The imaging system is designed by fully considering the limitation from the laboratory and beam diagnostics devices space. Two kinds of imaging system are designed and both show a good performance of imaging by beam trajectory simulation. The details of the beam optical requirement and optimization design are presented here. The beam line is designed and prepared to install in Tsinghua university linear electron accelerator laboratory for further precise electron radiography experiment study.



قيم البحث

اقرأ أيضاً

A dielectric-loaded linac powered by THz-pulses is one of the key parts of the Attosecond X-ray Science: Imaging and Spectroscopy (AXSIS) project at DESY, Hamburg. As in conventional accelerators, the AXSIS linac is designed to have phase velocity eq ual to the speed of light which, in this case, is realized by tuning the thickness of the dielectric layer and the radius of the vacuum channel. Therefore, structure fabrication errors will lead to a change in the beam dynamics and beam quality. Additionally, errors in the bunch injection will also affect the acceleration process and can cause beam loss on the linac wall. This paper numerically investigates the process of electron beam acceleration in the AXSIS linac, taking into account the aforementioned errors. Particle tracking simulations were done using the code ECHO, which uses a low-dispersive algorithm for the field calculation and was specially adapted for the dielectric-loaded accelerating structures.
Extensive beam-based feedback systems are planned as an integral part of the Next Linear Collider (NLC) control system. Wakefield effects are a significant influence on the feedback design, imposing both architectural and algorithmic constraints. Stu dies are in progress to assure the optimal selection of devices and to refine and confirm the algorithms for the system design. We show the results of initial simulations, along with evaluations of system response for various conditions of ground motion and other operational disturbances.
The treatment of flue gases from power plants and municipal or industrial wastewater using electron beam irradiation technology has been successfully demonstrated in small-scale pilot plants. The beam energy requirement is rather modest, on the order of a few MeV, however the adoption of the technology at an industrial scale requires the availability of high beam power, of the order of 1 MW, in a cost effective way. In this article we present the design of a compact superconducting accelerator capable of delivering a cw electron beam with a current of 1 A and an energy of 1 MeV. The main components are an rf-gridded thermionic gun and a conduction cooled beta= 0.5 elliptical Nb3Sn cavity with dual coaxial power couplers. An engineering and cost analysis shows that the proposed design would result in a processing cost competitive with alternative treatment methods.
High brightness electron accelerators, such as energy recovery linacs (ERL), often have complex particle distributions that can create difficulties in beam transport as well as matching to devices such as wigglers used to generate radiation from the beam. Optical transition radiation (OTR), OTR interferometry (OTRI) and optical diffraction-transition radiation interferometry (ODTRI) have proven to be effective tools for diagnosing both the spatial and angular distributions of charged particle beams. OTRI and ODTRI have been used to measure rms divergences and optical transverse phase space mapping has been demonstrated using OTRI. In this work we present the results of diagnostic experiments using OTR and ODR conducted at the Jefferson Laboratory 115 MeV ERL which show the presence of two separate components within the spatial and angular distributions of the beam. By assuming a correlation between the spatial and angular features we estimate an rms emittance value for each of the two components.
295 - Zheng Gao , Yuan He , Xian-Wu Wang 2016
Significant transient beam loading effects were observed during beam commissioning tests of prototype II of the injector for the Accelerator Driven Sub-critical (ADS) system, which took place at the Institute of Modern Physics, Chinese Academy of Sci ences, between October and December 2014. During these tests experiments were performed with CW operation of the cavities with pulsed beam current, and the system was configured to make use of a prototype digital low level radio frequency (LLRF) controller. The system was originally operated in pulsed mode with a simple PID feedback control algorithm, which was not able to maintain the desired gradient regulation during pulsed 10 mA beam operations. A unique simple transient beam loading compensation method which made use of a combination of PI feedback and feedforward control algorithm was implemented in order to significantly reduce the beam induced transient effect in the cavity gradients. The superconducting cavity field variation was reduced to less than 1.7% after turning on this control algorithm. The design and experimental results of this system are presented in this paper.