ترغب بنشر مسار تعليمي؟ اضغط هنا

Single Event Effect Hardness for the Front-end ASICs Applied in BGO Calorimeter of DAMPE Satellite

116   0   0.0 ( 0 )
 نشر من قبل Shanshan` Gao
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Dark Matter Particle Explorer (DAMPE) is a Chinese scientific satellite designed for cosmic ray study with a primary scientific goal of indirect search of dark matter particles. As a crucial sub-detector, BGO calorimeter measures the energy spectrum of cosmic rays in the energy range from 5 GeV to 10 TeV. In order to implement high-density front-end electronics (FEE) with the ability to measure 1848 signals from 616 photomultiplier tubes on the strictly constrained satellite platform, two kinds of 32-channel front-end ASICs, VA160 and VATA160, are customized. However, a space mission period of more than 3 years makes single event effect (SEE) a probable threat to reliability. In order to evaluate the SEE sensitivity of the chips and verify the effectiveness of mitigation methods, a series of laser-induced and heavy ion-induced SEE tests were performed. Benefiting from the single event latch-up (SEL) protection circuit for power supply, the triple module redundancy (TMR) technology for the configuration registers and optimized sequential design for data acquisition process, VA160 and VATA160 with the quantity of 54 and 32 respectively have been applied in the flight model of BGO calorimeter with radiation hardness assurance.

قيم البحث

اقرأ أيضاً

An onboard calibration circuit has been designed for the front-end electronics (FEE) of DAMPE BGO Calorimeter. It is mainly composed of a 12 bit DAC, an operation amplifier and an analog switch. Test results showed that a dynamic range of 0 ~ 30 pC w ith a precision of 5 fC was achieved, which meets the requirements of the front-end electronics. Furthermore, it is used to test the trigger function of the FEEs. The calibration circuit has been implemented and verified by all the environmental tests for both Qualification Model and Flight Model of DAMPE. The DAMPE satellite will be launched at the end of 2015 and the calibration circuit will perform onboard calibration in space.
A BGO electromagnetic calorimeter (ECAL) is built for the DArk Matter Particle Explorer (DAMPE) mission. The effect of temperature on the BGO ECAL was investigated with a thermal vacuum experiment. The light output of a BGO crystal depends on tempera ture significantly. The temperature coefficient of each BGO crystal bar has been calibrated, and a correction method is also presented in this paper.
The BGO calorimeter, which provides a wide measurement range of the primary cosmic ray spectrum, is a key sub-detector of Dark Matter Particle Explorer (DAMPE). The readout electronics of calorimeter consists of 16 pieces of Actel ProASIC Plus FLASH- based FPGA, of which the design-level flip-flops and embedded block RAMs are single event upset (SEU) sensitive in the harsh space environment. Therefore to comply with radiation hardness assurance (RHA), SEU mitigation methods, including partial triple modular redundancy (TMR), CRC checksum, and multi-domain reset are analyzed and tested by the heavy-ion beam test. Composed of multi-level redundancy, a FPGA design with the characteristics of SEU tolerance and low resource consumption is implemented for the readout electronics.
The water Cherenkov detector array (WCDA) is one of the key detectors in the large high altitude air shower observatory (LHAASO), which is proposed for very high gamma ray source survey. In WCDA, there are more than 3000 photomultiplier tubes (PMTs) scattered under water in an area of 80000 m2. As for the WCDA readout electronics, both high precision time and charge measurement is required over a large dynamic range from 1 photon electron (P.E.) to 4000 P.E. To reduce the electronics complexity and improve the system reliability, a readout scheme based on application specific integrated circuits (ASICs) is proposed. Two prototype ASICs were designed and tested. The first ASIC integrates amplification and shaping circuits for charge measurement and discrimination circuits used for time measurement. The shaped signal is further fed to the second ADC ASIC, while the output signal from the discriminator is digitized by the FPGA-based time-to-digital converter (TDC). Test results indicate that time resolution is better than 250 ps RMS, and the charge resolution is better than 10% at 1 P.E., and 1% at 4000 P.E. which meets the requirements of the LHAASO WCDA.
159 - H.T. Dai , Y.L. Zhang , J.J. Zang 2020
This paper is about a study on the response of the BGO calorimeter of DAMPE experiment. Four elements in Cosmic Ray nuclei are used as sources for this analysis. A feature resulting from the geomagnetic cutoff exhibits in the energy spectrum, both in simulated and reconstructed data, and is compared between them.