ترغب بنشر مسار تعليمي؟ اضغط هنا

Digital ultrasonically encoded (DUE) optical focusing into random media

112   0   0.0 ( 0 )
 نشر من قبل Jian Wei Tay
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Focusing light into opaque random or scattering media such as biological tissue is a much sought-after goal for biomedical applications such as photodynamic therapy, optical manipulation, and photostimulation. However, focusing with conventional lenses is restricted to one transport mean free path in scattering media, limiting both optical penetration depth and resolution. Focusing deeper is possible by using optical phase conjugation or wavefront shaping to compensate for the scattering. For practical applications, wavefront shaping offers the advantage of a robust optical system that is less sensitive to optical misalignment. Here, the phase of the incident light is spatially tailored using a phase-shifting array to pre-compensate for scattering. The challenge, then, is to determine the phase pattern which allows light to be optimally delivered to the target region. Optimization algorithms are typically employed for this purpose, with visible particles used as targets to generate feedback. However, using these particles is invasive, and light delivery is limited to fixed points. Here, we demonstrate a method for non-invasive and dynamic focusing, by using ultrasound encoding as a virtual guide star for feedback to an optimization algorithm. The light intensity at the acoustic focus was increased by an order of magnitude. This technique has broad biomedical applications, such as in optogenetics or photoactivation of drugs.



قيم البحث

اقرأ أيضاً

287 - Duygu Akbulut 2011
We study the focusing of light through random photonic materials using wavefront shaping. We explore a novel approach namely binary amplitude modulation. To this end, the light incident to a random photonic medium is spatially divided into a number o f segments. We identify the segments that give rise to fields that are out of phase with the total field at the intended focus and assign these a zero amplitude, whereas the remaining segments maintain their original amplitude. Using 812 independently controlled segments of light, we find the intensity at the target to be 75 +/- 6 times enhanced over the average intensity behind the sample. We experimentally demonstrate focusing of light through random photonic media using both an amplitude only mode liquid crystal spatial light modulator and a MEMS-based spatial light modulator. Our use of Micro Electro-Mechanical System (MEMS)-based digital micromirror devices for the control of the incident light field opens an avenue to high speed implementations of wavefront shaping.
Optical focusing through/inside scattering media, like multimode fiber and biological tissues, has significant impact in biomedicine yet considered challenging due to strong scattering nature of light. Previously, promising progress has been made, be nefiting from the iterative optical wavefront shaping, with which deep-tissue high-resolution optical focusing becomes possible. Most of iterative algorithms can overcome noise perturbations but fail to effectively adapt beyond the noise, e.g. sudden strong perturbations. Re-optimizations are usually needed for significant decorrelated medium since these algorithms heavily rely on the optimization in the previous iterations. Such ineffectiveness is probably due to the absence of a metric that can gauge the deviation of the instant wavefront from the optimum compensation based on the concurrently measured optical focusing. In this study, a square rule of binary-amplitude modulation, directly relating the measured focusing performance with the error in the optimized wavefront, is theoretically proved and experimentally validated. With this simple rule, it is feasible to quantify how many pixels on the spatial light modulator incorrectly modulate the wavefront for the instant status of the medium or the whole system. As an example of application, we propose a novel algorithm, dynamic mutation algorithm, with high adaptability against perturbations by probing how far the optimization has gone toward the theoretically optimum. The diminished focus of scattered light can be effectively recovered when perturbations to the medium cause significant drop of the focusing performance, which no existing algorithms can achieve due to their inherent strong dependence on previous optimizations. With further improvement, this study may boost or inspire many applications, like high-resolution imaging and stimulation, in instable scattering environments.
Non-invasively focusing light into strongly scattering media, such as biological tissue, is highly desirable but challenging. Recently, wavefront shaping technologies guided by ultrasonic encoding or photoacoustic sensing have been developed to addre ss this limitation. So far, these methods provide only acoustic diffraction-limited optical focusing. Here, we introduce nonlinear photoacoustic wavefront shaping (PAWS), which achieves optical diffraction-limited (i.e. single-speckle-grain) focusing in scattering media. We develop an efficient dual-pulse excitation approach to generate strong nonlinear photoacoustic (PA) signals based on the Grueneisen memory effect. These nonlinear PA signals are used as feedback to guide iterative wavefront optimization. By maximizing the amplitude of the nonlinear PA signal, light is effectively focused to a single optical speckle grain. Experimental results demonstrate a clear optical focus on the scale of 5-7 micrometers, which is ~10 times smaller than the acoustic focus in linear dimension, with an enhancement factor of ~6000 in peak fluence. This technology has the potential to provide highly confined strong optical focus deep in tissue for microsurgery of Parkinsons disease and epilepsy or single-neuron imaging and optogenetic activation.
A fundamental challenge in physics is controlling the propagation of waves in disordered media despite strong scattering from inhomogeneities. Spatial light modulators enable one to synthesize (shape) the incident wavefront, optimizing the multipath interference to achieve a specific behavior such as focusing light to a target region. However, the extent of achievable control was not known when the target region is much larger than the wavelength and contains many speckles. Here we show that for targets containing more than $g$ speckles, where $g$ is the dimensionless conductance, the extent of transmission control is substantially enhanced by the long-range mesoscopic correlations among the speckles. Using a filtered random matrix ensemble appropriate for coherent diffusion in open geometries, we predict the full distributions of transmission eigenvalues as well as universal scaling laws for statistical properties, in excellent agreement with our experiment. This work provides a general framework for describing wavefront-shaping experiments in disordered systems.
We report on a technically simple approach to achieve high-resolution and high-sensitivity Fourier-domain OCT imaging in the mid-infrared range. The proposed OCT system employs an InF3 supercontinuum source. A specially designed dispersive scanning s pectrometer based on a single InAsSb point detector is employed for detection. The spectrometer enables structural OCT imaging in the spectral range from 3140 nm to 4190 nm with a characteristic sensitivity of over 80 dB and an axial resolution below 8 um. The capabilities of the system are demonstrated for imaging of porous ceramic samples and transition-stage green parts fabricated using an emerging method of lithography-based ceramic manufacturing. Additionally, we demonstrate the performance and flexibility of the system by OCT imaging using an inexpensive low-power (average power of 16 mW above 3 um wavelength) mid-IR supercontinuum source.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا