ترغب بنشر مسار تعليمي؟ اضغط هنا

Tracking rare-isotope beams with microchannel plates

112   0   0.0 ( 0 )
 نشر من قبل Andrew Rogers
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon ${}^{56}$Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of $sim$1 mm for beam intensities up to $5times10^{5}$ pps.

قيم البحث

اقرأ أيضاً

The TexAT (Texas Active Target) detector is a new active-target time projection chamber (TPC) that was built at the Cyclotron Institute Texas A$&$M University. The detector is designed to be of general use for nuclear structure and nuclear astrophysi cs experiments with rare isotope beams. TexAT combines a highly segmented Time Projection Chamber (TPC) with two layers of solid state detectors. It provides high efficiency and flexibility for experiments with low intensity exotic beams, allowing for the 3D track reconstruction of the incoming and outgoing particles involved in nuclear reactions and decays.
Modern momentum imaging techniques allow for the investigation of complex molecules in the gas phase by detection of several fragment ions in coincidence. For these studies, it is of great importance that the single-particle detection efficiency e is as high as possible, as the overall efficiency scales with e over n, i.e. the power of the number of detected particles. Here we present measured absolute detection efficiencies for protons of several micro-channel plates (MCPs), including efficiency enhanced funnel MCPs. Furthermore, the relative detection efficiency for two-, three-, four-, and five-body fragmentation of CHBrClF has been examined. The funnel MCPs exhibit an efficiency of approx. 90 percent, gaining a factor of 24 (as compared to normal MCPs) in case of a five-fold ion coincidence detection.
To improve the ability of particle identification of the RIBLL2 separator at the HIRFL-CSR complex, a new high-performance detector for measuring fragment starting time and position at the F1 dispersive plane has been constructed and installed, and a method for achieving precise Br{ho} determination has been developed using the experimentally derived ion-optical transfer matrix elements from the measured position and ToF information. Using the high-performance detectors and the precise Br{ho} determination method, the fragments produced by the fragmentation of 78Kr at 300 MeV/nucleon were identified clearly at the RIBLL2-ETF under full momentum acceptance. The atomic number Z resolution of {sigma}Z~0.19 and the mass-to-charge ratio A/Q resolution of {sigma}A/Q~5.8e-3 were obtained for the 75As33+ fragment. This great improvement will increase the collection efficiency of exotic nuclei, extend the range of nuclei of interest from the A<40 mass region up to the A~80 mass region, and promote the development of radioactive nuclear beam experiments at the RIBLL2 separator.
103 - M. Mostamand , R. Li , J. Romans 2020
Hot cavity resonant ionization laser ion sources (RILIS) provide a multitude of radioactive ion beams with high ionization efficiency and element selective ionization. However, in hot cavity RILIS there still remains isobaric contaminations in the ex tracted beam from surface ionized species. An ion guide-laser ion source (IG-LIS) has been implemented that decouples the hot isotope production region from the laser ionization volume. A number of IG-LIS runs have been conducted to provide isobar free radioactive ion beams for experiments. Isobar suppression of up to 106 has been achieved, however, IG-LIS still suffers from an intensity loss of 50-100X as compared to hot cavity RILIS. Operating parameters for IG-LIS are being optimized and design improvements are being implemented into the prototype for robust and efficient on-line operation. Recent SIMION ion optics simulation results and the ongoing development status of the IG-LIS are presented.
New measurements and reaction model calculations are reported for single neutron pickup reactions onto a fast uc{22}{Mg} secondary beam at 84 MeV per nucleon. Measurements were made on both carbon and beryllium targets, having very different structu res, allowing a first investigation of the likely nature of the pickup reaction mechanism. The measurements involve thick reaction targets and $gamma$-ray spectroscopy of the projectile-like reaction residue for final-state resolution, that permit experiments with low incident beam rates compared to traditional low-energy transfer reactions. From measured longitudinal momentum distributions we show that the $ uc{12}{C} ( uc{22}{Mg}, uc{23}{Mg}+gamma)X$ reaction largely proceeds as a direct two-body reaction, the neutron transfer producing bound uc{11}{C} target residues. The corresponding reaction on the uc{9}{Be} target seems to largely leave the uc{8}{Be} residual nucleus unbound at excitation energies high in the continuum. We discuss the possible use of such fast-beam one-neutron pickup reactions to track single-particle strength in exotic nuclei, and also their expected sensitivity to neutron high-$ell$ (intruder) states which are often direct indicators of shell evolution and the disappearance of magic numbers in the exotic regime.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا