ترغب بنشر مسار تعليمي؟ اضغط هنا

The Hot and Energetic Universe: The Wide Field Imager (WFI) for Athena+

91   0   0.0 ( 0 )
 نشر من قبل Didier Barret
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Wide Field Imager (WFI) is one of the two scientific instruments proposed for the Athena+ X-ray observatory. It will provide imaging in the 0.1-15 keV band over a wide field, simultaneously with spectrally and time-resolved photon counting. The instrument is designed to make optimal use of the grasp (collecting area times solid angle product) provided by the optical design of the Athena+ mirror system (Willingale et al. 2013), by combining a sensitive approx. 40 diameter field of view (baseline; 50 goal) DEPFET detector with a pixel size properly sampling the angular resolution of 5 arc sec on-axis (half energy width).This synthesis makes the WFI a very powerful survey instrument, significantly surpassing currently existing capabilities (Nandra et al. 2013; Aird et al. 2013). In addition, the WFI will provide unprecedented simultaneous high-time resolution and high count rate capabilities for the observation of bright sources with low pile-up and high efficiency. In this paper, we summarize the instrument design, the status of the technology development, and the baseline performance.

قيم البحث

اقرأ أيضاً

The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), offering 2.5 eV spectral resolution, with ~5 pixels, over a field of view of 5 arc minutes in diameter. In this paper, we briefly describe the Athena+ mission concept and the X-IFU performance requirements. We then present the X-IFU detector and readout electronics principles, the current design of the focal plane assembly, the cooling chain and review the global architecture design. Finally, we describe the current performance estimates, in terms of effective area, particle background rejection, count rate capability and velocity measurements. Finally, we emphasize on the latest technology developments concerning TES array fabrication, spectral resolution and readout performance achieved to show that significant progresses are being accomplished towards the demanding X-IFU requirements.
The Athena+ X-ray mirror will provide a collecting area of 2 m^2 at 1 keV and an angular resolution of 5 arc seconds Half Energy Width. The manufacture and performance of this mirror is of paramount importance to the success of the mission. In order to provide the large collecting area a single aperture of diameter ~3 m must be densely populated with grazing incidence X-ray optics and to achieve the high angular resolution these optics must be of extremely high precision and aligned to tight tolerances. A large field of view of ~40 arc minutes diameter is possible using a combination of innovative technology and careful optical design. The large collecting area and large field of view deliver an impressive grasp of 0.5 deg^2 m^2 at 1 keV and the angular resolution will result in a source position accuracy of better than 1 arc second. The Silicon Pore Optics technology (SPO) which will deliver the impressive performance of the Athena+ mirror was developed uniquely by ESA and Cosine Measurement Systems specifically for the next generation of X-ray observatories and Athena+ represents the culmination of over 10 years of intensive technology developments. In this paper we describe the X-ray optics design, using SPO, which makes Athena+ possible for launch in 2028.
X-ray spectroscopy is key to address the theme of The Hot Universe, the still poorly understood astrophysical processes driving the cosmological evolution of the baryonic hot gas traceable through its electromagnetic radiation. Two future X-ray obser vatories: the JAXA-led XRISM (due to launch in the early 2020s), and the ESA Cosmic Vision L-class mission Athena (early 2030s) will provide breakthroughs in our understanding of how and when large-scale hot gas structures formed in the Universe, and in tracking their evolution from the formation epoch to the present day.
The ATHENA X-ray Observatory-IXO is a planned multinational orbiting X-ray observatory with a focal length of 11.5m. ATHENA aims to perform pointed observations in an energy range from 0.1 keV to 15 keV with high sensitivity. For high spatial and tim ing resolution imaging and spectroscopic observations the 640x640 pixel^2 large DePFET-technology based Wide field Imager (WFI) focal plane detector, providing a field of view of 18 arcsec will be the main detector. Based on the actual mechanics, thermal and shielding design we present estimates for the WFI cosmic ray induced background obtained by the use of Monte-Carlo simulations and possible background reduction measures.
The Science Products Module (SPM), a US contribution to the Athena Wide Field Imager, is a highly capable secondary CPU that performs special processing on the science data stream. The SPM will have access to both accepted X-ray events and those that were rejected by the on-board event recognition processing. It will include two software modules. The Transient Analysis Module will perform on-board processing of the science images to identify and characterize variability of the prime target and/or detection of serendipitous transient X-ray sources in the field of view. The Background Analysis Module will perform more sophisticated flagging of potential background events as well as improved background characterization, making use of data that are not telemetered to the ground, to provide improved background maps and spectra. We present the preliminary design of the SPM hardware as well as a brief overview of the software algorithms under development.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا