ترغب بنشر مسار تعليمي؟ اضغط هنا

Soft X-ray reflectivity: from quasi-perfect mirrors to accelerator walls

373   0   0.0 ( 0 )
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English
 تأليف F. Schafers




اسأل ChatGPT حول البحث

Reflection of light from surfaces is a very common, but complex phenomenon not only in science and technology, but in every day life. The underlying basic optical principles have been developed within the last five centuries using visible light available from the sun or other laboratory light sources. X-rays were detected in 1895, and the full potential of soft- and hard-x ray radiation as a probe for the electronic and geometric properties of matter, for material analysis and its characterisation is available only since the advent of synchrotron radiation sources some 50 years ago. On the other hand high-brilliance and high power synchrotron radiation of present-days 3rd and 4th generation light sources is not always beneficial. Highenergy machines and accelerator-based light sources can suffer from a serious performance drop or limitations due to interaction of the synchrotron radiation with the accelerator walls, thus producing clouds of photoelectrons (e-cloud) which in turn interact with the accelerated beam. Thus the suitable choice of accelerator materials and their surface coating, which determines the x-ray optical behaviour is of utmost importance to achieve ultimate emittance. Basic optical principles and examples on reflectivity for selected materials are given here.

قيم البحث

اقرأ أيضاً

374 - S. Reiche , G. Knopp , B. Pedrini 2020
X-ray free-electron lasers (FEL) deliver ultrabright X-ray pulses, but not the sequences of phase-coherent pulses required for time-domain interferometry and control of quantum states. For conventional split-and-delay schemes to produce such sequence s the challenge stems from extreme stability requirements when splitting Angstrom wavelength beams where tiniest path length differences introduce phase jitter. We describe an FEL mode based on selective electron bunch degradation and transverse beam shaping in the accelerator, combined with a self-seeded photon emission scheme. Instead of splitting the photon pulses after their generation by the FEL, we split the electron bunch in the accelerator, prior to photon generation, to obtain phase-locked X-ray pulses with sub-femtosecond duration. Time-domain interferometry becomes possible, enabling the concomitant program of classical and quantum optics experiments with X-rays. The scheme leads to new scientific benefits of cutting-edge FELs with attosecond and/or high-repetition rate capabilities, ranging from the X-ray analog of Fourier transform infrared spectroscopy to damage-free measurements.
Multilayer X-ray mirrors consist of a coating of a large number of alternate layers of high Z and low Z materials with a typical thickness of 10-100 Angstrom, on a suitable substrate. Such coatings play an important role in enhancing the reflectivity of X-ray mirrors by allowing reflections at angles much larger than the critical angle of X-ray reflection for the given materials. Coating with an equal thickness of each bilayer enhances the reflectivity at discrete energies, satisfying Bragg condition. However, by systematically varying the bilayer thickness in the multilayer stack, it is possible to design X-ray mirrors having enhanced reflectivity over a broad energy range. One of the most important applications of such a depth graded multilayer mirror is to realize hard X-ray telescopes for astronomical purposes. Design of such multilayer X-ray mirrors and their characterization with X-ray reflectivity measurements require appropriate software tools. We have initiated the development of hard X-ray optics for future Indian X-ray astronomical missions, and in this context, we have developed a program, DarpanX, to calculate X-ray reflectivity for single and multilayer mirrors. It can be used as a stand-alone tool for designing multilayer mirrors with required characteristics. But more importantly, it has been implemented as a local model for the popular X-ray spectral fitting program, XSPEC, and thus can be used for accurate fitting of the experimentally measured X-ray reflectivity data. DarpanX is implemented as a Python 3 module, and an API is provided to access the underlying algorithms. Here we present details of DarpanX implementation and its validation for different type multilayer structures. We also demonstrate the model fitting capability of DarpanX for experimental X-ray reflectivity measurements of single and multilayer samples.
We report the design and construction of a novel soft x-ray diffractometer installed at Diamond Light Source. The beamline endstation RASOR is constructed for general users and designed primarily for the study of single crystal diffraction and thin f ilm reflectivity. The instrument is comprised of a limited three circle ({theta}, 2{theta}, {chi}) diffractometer with an additional removable rotation ({phi}) stage. It is equipped with a liquid helium cryostat, and post-scatter polarization analysis. Motorised motions are provided for the precise positioning of the sample onto the diffractometer centre of rotation, and for positioning the centre of rotation onto the x-ray beam. The functions of the instrument have been tested at Diamond Light Source, and initial test measurements are provided, demonstrating the potential of the instrument.
Flying plasma mirrors induced by intense lasers has been proposed as a promising way to generate few-cycle EUV or X-ray lasers. In addition, if such a relativistic plasma mirror can accelerate, then it would serve as an analog black hole to investiga te the information loss paradox associated with the black hole Hawking evaporation. Among these applications, the reflectivity, which is usually frequency-dependent, would affect the outgoing photon spectrum and therefore impact on the analysis of the physics under investigation. In this paper, these two issues are investigated analytically and numerically with one-dimensional particle-in-cell (PIC) simulations. Based on our simulation results, we propose a new model that provides a better estimate of the reflectivity than those studied previously. Besides, we found that the peak frequency of the reflected spectrum of a gaussian incident wave deviates from the expected value, $4gamma^2omega$, due to the dependence of reflectivity on the frequency of the incident wave.
111 - A.H. Lumpkin 2018
We report the initial demonstrations of the use of single crystals in indirect x-ray imaging for x-ray phase contrast imaging at the Washington University in St. Louis Computational Bioimaging Laboratory (CBL). Based on single Gaussian peak fits to t he x-ray images, we observed a four times smaller system point spread function (21 {mu}m (FWHM)) with the 25-mm diameter single crystals than the reference polycrystalline phosphors 80-{mu}m value. Potential fiber-optic plate depth-of-focus aspects and 33-{mu}m diameter carbon fiber imaging are also addressed.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا