ترغب بنشر مسار تعليمي؟ اضغط هنا

Improving imaging resolution of shaking targets by Fourier-transform ghost diffraction

117   0   0.0 ( 0 )
 نشر من قبل Gong Wenlin
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

For conventional imaging, shaking of the imaging system or the target leads to the degradation of imaging resolution. In this work, the influence of the targets shaking to fourier-transform ghost diffraction (FGD) is investigated. The analytical results, which are backed up by numerical simulation and experiments, demonstrate that the quiver of target has no effect on the resolution of FGD, thus the targets imaging with high spatial resolution can be always achieved by phase-retrieval method from the FGD patterns. This approach can be applied in high-precision imaging systems, to overcome the influence of the systems shaking to imaging resolution.



قيم البحث

اقرأ أيضاً

Knowledge gained through X-ray crystallography fostered structural determination of materials and greatly facilitated the development of modern science and technology in the past century. Atomic details of sample structures is achievable by X-ray cry stallography, however, it is only applied to crystalline structures. Imaging techniques based on X-ray coherent diffraction or zone plates are capable of resolving the internal structure of non-crystalline materials at nanoscales, but it is still a challenge to achieve atomic resolution. Here we demonstrate a novel lensless Fourier-transform ghost imaging method with pseudo-thermal hard X-rays by measuring the second-order intensity correlation function of the light. We show that high resolution Fourier-transform diffraction pattern of a complex amplitude sample can be achieved at Fresnel region and the amplitude and phase distributions of a sample in spatial domain can be retrieved successfully. The method of lensless X-ray Fourier-transform ghost imaging extends X-ray crystallography to non-crystalline samples, and its spatial resolution is limited only by the wavelength of the X-ray, thus atomic resolution should be routinely obtainable. Since highly coherent X-ray source is not required, comparing to conventional X-ray coherent diffraction imaging, the method can be implemented with laboratory X-ray sources, and it also provides a potential solution for lensless diffraction imaging with fermions, such as neutron and electron where the intensive coherent source usually is not available.
As one of important analysis tools, microscopes with high spatial resolution are indispensable for scientific research and medical diagnosis, and much attention is always focused on the improvement of resolution. Over the past decade, a novel techniq ue called ghost imaging has been developed that may provide a new approach toward increasing the resolution of an imaging system. In this paper, we introduce this technique into microscopes for the first time and report a proof-of-principle experimental demonstration of a microscope scheme based on ghost imaging.
Experimental data with digital masks and a theoretical analysis are presented for an imaging scheme that we call time-correspondence differential ghost imaging (TCDGI). It is shown that by conditional averaging of the information from the reference d etector but with the negative signals inverted, the quality of the reconstructed images is in general superior to all other ghost imaging (GI) methods to date. The advantages of both differential GI and time-correspondence GI are combined, plus less data manipulation and shorter computation time are required to obtain equivalent quality images under the same conditions. This TCDGI method offers a general approach applicable to all GI techniques, especially when objects with continuous gray tones are involved.
Fourier analysis of ghost imaging (FAGI) is proposed in this paper to analyze the properties of ghost imaging with thermal light sources. This new theory is compatible with the general correlation theory of intensity fluctuation and could explain som e amazed phenomena. Furthermore we design a series of experiments to verify the new theory and investigate the inherent properties of ghost imaging.
289 - A. Meda , A. Caprile , A. Avella 2015
We develop a new approach in magneto-optical imaging (MOI), applying for the first time a ghost imaging (GI) protocol to perform Faraday microscopy. MOI is of the utmost importance for the investigation of magnetic properties of material samples, thr ough Weiss domains shape, dimension and dynamics analysis. Nevertheless, in some extreme conditions such as e. g. cryogenic temperatures or high magnetic fields application, there exists a lack of domains images due to the difficulty in creating an efficient imaging system in such environments. Here we present an innovative MOI technique that separates the imaging optical path from the one illuminating the object. The technique is based on thermal light GI and exploits correlations between light beams to retrieve the image of magnetic domains. As a proof of principle, the proposed technique is applied to the Faraday magneto-optical observation of the remanence domain structure of an yttrium iron garnet sample.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا