ترغب بنشر مسار تعليمي؟ اضغط هنا

Investigations of surface quality and SRF cavity performance

262   0   0.0 ( 0 )
 نشر من قبل Wu, Genfa
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English
 تأليف G. Wu - M. Ge




اسأل ChatGPT حول البحث

Magnetic field enhancement has been studied in the past through replica and cavity cutting. Considerable progress of niobium cavity manufacturing and processing has been made since then. Wide variety of single cell cavities has been analyzed through replica technique. Their RF performances were compared in corresponding to geometric RF surface quality. It is concluded that the surface roughness affects cavity performance mostly in secondary role. The other factors must have played primary role in cavity performance limitations.



قيم البحث

اقرأ أيضاً

78 - J.P. Holzbauer 2018
SRF cavity quality factors can be accurately measured using RF-power based techniques only when the cavity is very close to critically coupled. This limitation is from systematic errors driven by non-ideal RF components. When the cavity is not close to critically coupled, these systematic effects limit the accuracy of the measurements. The combination of the complex base-band envelopes of the cavity RF signals in combination with a trombone in the circuit allow the relative calibration of the RF signals to be extracted from the data and systematic effects to be characterized and suppressed. The improved calibration allows accurate measurements to be made over a much wider range of couplings. Demonstration of these techniques during testing of a single-spoke resonator with a coupling factor of near 7 will be presented, along with recommendations for application of these techniques.
The surface resistance of an RF superconductor depends on the surface temperature, the residual resistance and various superconductor parameters, e.g. the energy gap, and the electron mean free path. These parameters can be determined by measuring th e quality factor Q0 of a SRF cavity in helium-baths of different temperatures. The surface resistance can be computed from Q0 for any cavity geometry, but it is not trivial to determine the temperature of the surface when only the temperature of the helium bath is known. Traditionally, it was approximated that the surface temperature on the inner surface of the cavity was the same as the temperature of the helium bath. This is a good approximation at small RF-fields on the surface, but to determine the field dependence of Rs, one cannot be restricted to small field losses. Here we show the following: (1) How computer simulations can be used to determine the inside temperature Tin so that Rs(Tin) can then be used to extract the superconducting parameters. The computer code combines the well-known programs, the HEAT code and the SRIMP code. (2) How large an error is created when assuming the surface temperature is same as the temperature of the helium bath? It turns out that this error is at least 10% at high RF-fields in typical cases.
200 - R. Eichhorn , C. Daly , F. Furuta 2014
Over the past years it became evident that the quality factor of a superconducting cavity is not only determined by its surface preparation procedure, but is also influenced by the way the cavity is cooled down. Moreover, different data sets exists, some of them indicate that a slow cool-down through the critical temperature is favourable while other data states the exact opposite. Even so there where speculations and some models about the role of thermo-currents and flux-pinning, the difference in behaviour remained a mystery. In this paper we will for the first time present a consistent theoretical model which we confirmed by data that describes the role of thermo-currents, driven by temperature gradients and material transitions. We will clearly show how they impact the quality factor of a cavity, discuss our findings, relate it to findings at other labs and develop mitigation strategies which especially addresses the issue of achieving high quality factors of so-called nitrogen doped cavities in horizontal test.
SRF cavities for particle acceleration are conventionally operated immersed in a bath of liquid helium at 4.2 K and below. Although this cooling configuration is practically and economically viable for large scientific accelerator installations, it m ay not be so for smaller accelerators intended for industrial applications such as the treatment of wastewater, sludge, flue gases, etc. In this paper, we describe a procedure to operate SRF cavities without liquid helium that can be used to construct electron-beam sources for industrial applications of electron irradiation (1-10 MeV electron energy). In this procedure, an elliptical single-cell 650 MHz niobium-tin coated niobium cavity is coupled to a closed-cycle 4 K cryocooler using high purity aluminum thermal links. The cryocooler conductively extracts heat (RF dissipation) from the cavity without requiring liquid helium around the cavity. We present construction details of this cryocooler conduction-cooling technique and systematic experiments that have demonstrated ~10 MV/m cw gradient on the cavity. By straightforward scaling up the cavity length and number of cryocoolers, the technique will provide the complete range of 1-10 MeV electron energy for industrial applications.
The NL-eEDM collaboration is building an experimental setup to search for the permanent electric dipole moment of the electron in a slow beam of cold barium fluoride molecules [Eur. Phys. J. D, 72, 197 (2018)]. Knowledge of molecular properties of Ba F is thus needed to plan the measurements and in particular to determine an optimal laser-cooling scheme. Accurate and reliable theoretical predictions of these properties require incorporation of both high-order correlation and relativistic effects in the calculations. In this work theoretical investigations of the ground and the lowest excited states of BaF and its lighter homologues, CaF and SrF, are carried out in the framework of the relativistic Fock-space coupled cluster (FSCC) and multireference configuration interaction (MRCI) methods. Using the calculated molecular properties, we determine the Franck-Condon factors (FCFs) for the $A^2Pi_{1/2} rightarrow X^2Sigma^{+}_{1/2}$ transition, which was successfully used for cooling CaF and SrF and is now considered for BaF. For all three species, the FCFs are found to be highly diagonal. Calculations are also performed for the $B^2Sigma^{+}_{1/2} rightarrow X^2Sigma^{+}_{1/2}$ transition recently exploited for laser-cooling of CaF; it is shown that this transition is not suitable for laser-cooling of BaF, due to the non-diagonal nature of the FCFs in this system. Special attention is given to the properties of the $A^2Delta$ state, which in the case of BaF causes a leak channel, in contrast to CaF and SrF species where this state is energetically above the excited states used in laser-cooling. We also present the dipole moments of the ground and the excited states of the three molecules and the transition dipole moments (TDMs) between the different states.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا