ترغب بنشر مسار تعليمي؟ اضغط هنا

The worldwide NORM production and a fully automated gamma-ray spectrometer for their characterization

206   0   0.0 ( 0 )
 نشر من قبل Gerti Xhixha Mr.
 تاريخ النشر 2012
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

Materials containing radionuclides of natural origin, which is modified by human made processes and being subject to regulation because of their radioactivity are known as NORM. We present a brief review of the main categories of non-nuclear industries together with the levels of activity concentration in feed raw materials, products and waste, including mechanisms of radioisotope enrichments. The global management of NORM shows a high level of complexity, mainly due to different degrees of radioactivity enhancement and the huge amount of worldwide waste production. The future tendency of guidelines concerning environmental protection will require both a systematic monitoring based on the ever-increasing sampling and high performance of gamma ray spectroscopy. On the ground of these requirements a new low background fully automated high-resolution gamma-ray spectrometer MCA_Rad has been developed. The design of Pb and Cu shielding allowed to reach a background reduction of two order of magnitude with respect to laboratory radioactivity. A severe lowering of manpower cost is obtained through a fully automation system, which enables up to 24 samples to be measured without any human attendance. Two coupled HPGe detectors increase the detection efficiency, performing accurate measurements on sample volume (180 cc) with a reduction of sample transport cost of material. Details of the instrument calibration method are presented. MCA_Rad system can measure in less than one hour a typical NORM sample enriched in U and Th with some hundreds of Bq/kg, with an overall uncertainty less than 5%. Quality control of this method has been tested. Measurements of certified reference materials RGK-1, RGU-2 and RGTh-1 containing concentrations of K, U and Th comparable to NORM have been performed, resulting an overall relative discrepancy of 5% among central values within the reported uncertainty.



قيم البحث

اقرأ أيضاً

A dedicated setup for the in-beam measurement of absolute cross sections of astrophysically relevant charged-particle induced reactions is presented. These, usually very low, cross sections at energies of astrophysical interest are important to impro ve the modeling of the nucleosynthesis processes of heavy nuclei. Particular emphasis is put on the production of the $p$ nuclei during the astrophysical $gamma$ process. The recently developed setup utilizes the high-efficiency $gamma$-ray spectrometer HORUS, which is located at the 10 MV FN tandem ion accelerator of the Institute for Nuclear Physics in Cologne. The design of this setup will be presented and results of the recently measured $^{89}$Y(p,$gamma$)$^{90}$Zr reaction will be discussed. The excellent agreement with existing data shows, that the HORUS spectrometer is a powerful tool to determine total and partial cross sections using the in-beam method with high-purity germanium detectors.
Background: Neutron-induced reactions are a significant concern for experiments that require extremely low levels of radioactive backgrounds. Measurements of gamma-ray production cross sections over a wide energy range will help to predict and identi fy neutron backgrounds in these experiments. Purpose: Determine partial gamma-ray production cross sections for neutron-induced reactions in natural neon. Methods: The broad-spectrum neutron beam at the Los Alamos Neutron Science Center (LANSCE) was used for the measurement. Gamma rays from neutron-induced reactions were detected using the GErmanium Array for Neutron Induced Excitations (GEANIE). Results: Partial gamma-ray cross sections were measured for the first excited-state transitions in Ne-20 and Ne-22. The measured cross sections were compared to the TALYS and CoH3 nuclear reaction codes. Conclusions: These are the first experimental data for (n,n) reactions in neon. In addition to providing data to aid in the prediction and identification of neutron backgrounds in low-background experiments, these new measurements will help refine cross-section predictions in a mass region where models are not well constrained.
156 - Y. Iwata , Y. Inoue , M. Minowa 2007
We propose a new method of alpha($alpha$)-ray measurement that detects helium atoms with a Quadrupole Mass Spectrometer(QMS). A demonstration is undertaken with a plastic-covered $^{241}$Am $alpha$-emitting source to detect $alpha$-rays stopped in th e capsule. We successfully detect helium atoms that diffuse out of the capsule by accumulating them for one to 20 hours in a closed chamber. The detected amount is found to be proportional to the accumulation time. Our method is applicable to probe $alpha$-emitting radioactivity in bulk material.
The Miniature X-ray Solar Spectrometer (MinXSS) are twin 3U CubeSats. The first of the twin CubeSats (MinXSS-1) launched in December 2015 to the International Space Station for deployment in mid-2016. Both MinXSS CubeSats utilize a commercial off the shelf (COTS) X-ray spectrometer from Amptek to measure the solar irradiance from 0.5 to 30 keV with a nominal 0.15 keV FWHM spectral resolution at 5.9 keV, and a LASP-developed X-ray broadband photometer with similar spectral sensitivity. MinXSS design and development has involved over 40 graduate students supervised by professors and professionals at the University of Colorado at Boulder. The majority of previous solar soft X-ray measurements have been either at high spectral resolution with a narrow bandpass or spectrally integrating (broadband) photometers. MinXSS will conduct unique soft X-ray measurements with moderate spectral resolution over a relatively large energy range to study solar active region evolution, solar flares, and the effects of solar soft X-ray emission on Earths ionosphere. This paper focuses on the X-ray spectrometer instrument characterization techniques involving radioactive X-ray sources and the National Institute for Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF). Spectrometer spectral response, spectral resolution, response linearity are discussed as well as future solar science objectives.
Background: Neutron-induced backgrounds are a significant concern for experiments that require extremely low levels of radioactive backgrounds such as direct dark matter searches and neutrinoless double-beta decay experiments. Unmeasured neutron scat tering cross sections are often accounted for incorrectly in Monte Carlo simulations. Purpose: Determine partial gamma-ray production cross sections for (n,xng) reactions in natural argon for incident neutron energies between 1 and 30 MeV. Methods: The broad spectrum neutron beam at the Los Alamos Neutron Science Center (LANSCE) was used used for the measurement. Neutron energies were determined using time-of-flight and resulting gamma rays from neutron-induced reactions were detected using the GErmanium Array for Neutron Induced Excitations (GEANIE). Results: Partial gamma-ray cross sections were measured for six excited states in Ar-40 and two excited states in Ar-39. Measured (n,xng) cross sections were compared to the TALYS and CoH3 nuclear reaction codes. Conclusions: These new measurements will help to identify potential backgrounds in neutrinoless double-beta decay and dark matter experiments that use argon as a detection medium or shielding. The measurements will also aid in the identification of neutron interactions in these experiments through the detection of gamma rays produced by (n,xng) reactions.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا