We report on the fabrication of sensitive nanotorsional resonators, which can be utilized as magnetometers for investigating the magnetization dynamics in small magnetic elements. The thermo-mechanical noise is calibrated with the resonator displacement in order to determine the ultimate mechanical torque sensitivity of the magnetometer.

قيم البحث

اقرأ أيضاً

We report on the thermomechanical and thermal tuning properties of curved-mirror Fabry-Perot resonators, fabricated by the guided assembly of circular delamination buckles within a multilayer a-Si/SiO2 stack. Analytical models for temperature depende nce, effective spring constants, and mechanical mode frequencies are described and shown to be in good agreement with experimental results. The cavities exhibit mode volumes as small as $sim10lambda^3$, reflectance-limited finesse $sim3times10^3$, and mechanical resonance frequencies in the MHz range. Monolithic cavity arrays of this type might be of interest for applications in sensing, cavity quantum electrodynamics, and optomechanics.
Contactless characterization of mechanical resonances using Fabry-Perot interferometry is a powerful tool to study the mechanical and dynamical properties of atomically thin membranes. However, amplitude calibration is often not performed, or only po ssible by making assumptions on the device parameters such as its mass or the temperature. In this work, we demonstrate a calibration technique that directly measures the oscillation amplitude by detecting higher harmonics that arise from nonlinearities in the optical transduction. Employing this technique, we calibrate the resonance amplitude of two-dimensional nanomechanical resonators, without requiring knowledge of their mechanical properties, actuation force, geometric distances or the laser intensity.
We provide a detailed description of a general procedure by which a nano/micro-mechanical resonator can be calibrated using its thermal motion. A brief introduction to the equations of motion for such a resonator is presented, followed by a detailed derivation of the corresponding power spectral density (PSD) function. The effective masses for a number of different resonator geometries are determined using both finite element method (FEM) modeling and analytical calculations.
218 - E. Collin , M. Defoort , K. Lulla 2015
We report on experiments performed in vacuum and at cryogenic temperatures on a tri-port nano-electro-mechanical (NEMS) device. One port is a very non-linear capacitive actuation, while the two others implement the magnetomotive scheme with a linear input force port and a (quasi-linear) output velocity port. We present an experimental method enabling a full characterization of the nanomechanical device harmonic response: the non-linear capacitance function $C(x)$ is derived, and the normal parameters $k$ and $m$ (spring constant and mass) of the mode under study are measured through a careful definition of the motion (in meters) and of the applied forces (in Newtons). These results are obtained with a series of purely electric measurements performed without disconnecting/reconnecting the device, and rely only on known DC properties of the circuit, making use of a thermometric property of the oscillator itself: we use the Young modulus of the coating metal as a thermometer, and the resistivity for Joule heating. The setup requires only three connecting lines without any particular matching, enabling the preservation of a high impedance NEMS environment even at MHz frequencies. The experimental data are fit to a detailed electrical and thermal model of the NEMS device, demonstrating a complete understanding of its dynamics. These methods are quite general and can be adapted (as a whole, or in parts) to a large variety of elecromechanical devices.
Single electron transistors (SETs) fabricated from single-walled carbon nanotubes (SWNTs) can be operated as highly sensitive charge detectors reaching sensitivity levels comparable to metallic radio frequency SETs (rf-SETs). Here we demonstrate how the charge sensitivity of the device can be improved by using the mechanical oscillations of a single-walled carbon nanotube quantum dot. To optimize the charge sensitivity $delta Q$, we drive the mechanical resonator far into the nonlinear regime and bias it to an operating point where the mechanical third order nonlinearity is cancelled out. This way we enhance $delta Q$, from 6 $mu e/sqrt{textrm{Hz}}$ for the static case, to 0.97 $mu e/sqrt{textrm{Hz}}$, at a probe frequency of $sim$ 1.3 kHz.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا