First results about on-ground calibration of the Silicon Tracker for the AGILE satellite

149   0   0.0 ( 0 )
 نشر من قبل Paolo Walter Cattaneo
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The AGILE scientific instrument has been calibrated with a tagged $gamma$-ray beam at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF). The goal of the calibration was the measure of the Point Spread Function (PSF) as a function of the photon energy and incident angle and the validation of the Monte Carlo (MC) simulation of the silicon tracker operation. The calibration setup is described and some preliminary results are presented.



قيم البحث

اقرأ أيضاً

DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector, successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientif ic goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mechanisms of cosmic-ray particles, and gamma-ray astronomy. DAMPE consists of four sub-detectors: a plastic scintillator strip detector, a Silicon-Tungsten tracKer-converter (STK), a BGO calorimeter and a neutron detector. The STK is composed of six double layers of single-sided silicon micro-strip detectors interleaved with three layers of tungsten for photon
With the observation of the gravitational wave event of August 17th 2017 the multi-messenger astronomy era has definitely begun. With the opening of this new panorama, it is necessary to have new instruments and a perfect coordination of the existing observatories. Crystal Eye is a detector aimed at the exploration of the electromagnetic counterpart of the gravitational waves. Such events generated by neutron stars mergers are associated with gamma-ray bursts (GRB). At present, there are few instruments in orbit able to detect photons in the energy range going from tens of keV up to few MeV. These instruments belong to two different old observation concepts: the all sky monitors (ASM) and the telescopes. The detector we propose is a crossover technology, the Crystal Eye: a wide field of view observatory in the energy range from 10 keV to 10 MeV with a pixelated structure. A pathfinder will be launched with Space RIDER in 2022. We here present the preliminary results of the characterization of the first pixel.
Over almost three decades the TAUP conference has seen a remarkable momentum gain in direct dark matter search. An important accelerator were first indications for a modulating signal rate in the DAMA/NaI experiment reported in 1997. Today the presen ce of an annual modulation, which matches in period and phase the expectation for dark matter, is supported at > 9$sigma$ confidence. The underlying nature of dark matter, however, is still considered an open and fundamental question of particle physics. No other direct dark matter search could confirm the DAMA claim up to now; moreover, numerous null-results are in clear contradiction under so-called standard assumptions for the dark matter halo and the interaction mechanism of dark with ordinary matter. As both bear a dependence on the target material, resolving this controversial situation will convincingly only be possible with an experiment using sodium iodide (NaI) as target. COSINUS aims to even go a step further by combining NaI with a novel detection approach. COSINUS aims to operate NaI as a cryogenic calorimeter reading scintillation light and phonon/heat signal. Two distinct advantages arise from this approach, a substantially lower energy threshold for nuclear recoils and particle identification on an event-by-event basis. These key benefits will allow COSINUS to clarify a possible nuclear recoil origin of the DAMA signal with comparatively little exposure of O(100kg days) and, thereby, answer a long-standing question of particle physics. Today COSINUS is in R&D phase; in this contribution we show results from the 2nd prototype, albeit the first one of the final foreseen detector design. The key finding of this measurement is that pure, undoped NaI is a truly excellent scintillator at low temperatures: We measure 13.1% of the total deposited energy in the NaI crystal in the form of scintillation light (in the light detector).
AGILE is a mission of the Italian Space Agency (ASI) Scientific Program dedicated to gamma-ray astrophysics, operating in a low Earth orbit since April 23, 2007. It is designed to be a very light and compact instrument, capable of simultaneously dete cting and imaging photons in the 18 keV to 60 keV X-ray energy band and in the 30 MeV{50 GeV gamma-ray energy with a good angular resolution (< 1 deg at 1 GeV). The core of the instrument is the Silicon Tracker complemented with a CsI calorimeter and a AntiCoincidence system forming the Gamma Ray Imaging Detector (GRID). Before launch, the GRID needed on-ground calibration with a tagged gamma-ray beam to estimate its performance and validate the Monte Carlo simulation. The GRID was calibrated using a tagged gamma-ray beam with energy up to 500 MeV at the Beam Test Facilities at the INFN Laboratori Nazionali di Frascati. These data are used to validate a GEANT3 based simulation by comparing the data and the Monte Carlo simulation by measuring the angular and energy resolutions. The GRID angular and energy resolutions obtained using the beam agree well with the Monte Carlo simulation. Therefore the simulation can be used to simulate the same performance on-light with high reliability.
414 - A. Biland , T. Bretz , J. Bu{ss} 2014
The First G-APD Cherenkov Telescope (FACT) is the first in-operation test of the performance of silicon photo detectors in Cherenkov Astronomy. For more than two years it is operated on La Palma, Canary Islands (Spain), for the purpose of long-term m onitoring of astrophysical sources. For this, the performance of the photo detectors is crucial and therefore has been studied in great detail. Special care has been taken for their temperature and voltage dependence implementing a correction method to keep their properties stable. Several measurements have been carried out to monitor the performance. The measurements and their results are shown, demonstrating the stability of the gain below the percent level. The resulting stability of the whole system is discussed, nicely demonstrating that silicon photo detectors are perfectly suited for the usage in Cherenkov telescopes, especially for long-term monitoring purpose.