ترغب بنشر مسار تعليمي؟ اضغط هنا

Streamlined Calibrations of the ATLAS Precision Muon Chambers for Initial LHC Running

353   0   0.0 ( 0 )
 نشر من قبل Erez Etzion
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English
 تأليف N. Amram




اسأل ChatGPT حول البحث

The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functions depend on MDT environmental parameters and so must be appropriately calibrated for local chamber conditions. We report on the creation and application of a gas monitor system based calibration program for muon track reconstruction in the LHC startup phase.

قيم البحث

اقرأ أيضاً

A new small-diameter Monitored Drift Tube (sMDT) chamber has been developed for the muon spectrometer of the ATLAS experiment to handle the higher collision rates expected at the CERN High Luminosity Large Hadron Collider (HL-LHC). This paper present s measurements of the tracking resolution and hit efficiency of two prototype sMDT chambers constructed at the University of Michigan. Using cosmic-ray muons the sMDT tracking resolution of 103.7$pm8.1$ textmu m was measured for one chamber and 101.8$pm$7.8 textmu m for the other, compared with a design resolution of 106 textmu m. A further tracking resolution improvement to 83.4$pm$7.8 textmu m was obtained by using new high-gain readout electronics which will be added for HL-LHC. An average tracking efficiency of (98.5$pm$0.2)% was found for both chambers. The methodology used to determine the detector tracking resolution and efficiency, including reconstruction of sMDT data and a Geant4 simulation of the test chamber, is presented in detail.
119 - P. Gadow , O. Kortner , S. Kortner 2015
Highly selective first-level triggers are essential to exploit the full physics potential of the ATLAS experiment at High-Luminosity LHC (HL-LHC). The concept for a new muon trigger stage using the precision monitored drift tube (MDT) chambers to sig nificantly improve the selectivity of the first-level muon trigger is presented. It is based on fast track reconstruction in all three layers of the existing MDT chambers, made possible by an extension of the first-level trigger latency to six microseconds and a new MDT read-out electronics required for the higher overall trigger rates at the HL-LHC. Data from $pp$-collisions at $sqrt{s} = 8,mathrm{TeV}$ is used to study the minimal muon transverse momentum resolution that can be obtained using the MDT precision chambers, and to estimate the resolution and efficiency of the MDT-based trigger. A resolution of better than $4.1%$ is found in all sectors under study. With this resolution, a first-level trigger with a threshold of $18,mathrm{GeV}$ becomes fully efficient for muons with a transverse momentum above $24,mathrm{GeV}$ in the barrel, and above $20,mathrm{GeV}$ in the end-cap region.
The High-Luminosity LHC (HL-LHC) will provide the unique opportunity to explore the nature of physics beyond the Standard Model of strong and electroweak interactions. Highly selective first-level triggers are essential for the physics programme of t he ATLAS experiment at HL-LHC, where the instantaneous luminosity will exceed the instantaneous LHC Run 1 luminosity by about an order of magnitude. The ATLAS first-level muon trigger rate is dominated by low momentum muons, which are accepted because of the moderate momentum resolution of the RPC and TGC trigger chambers. This limitation can be overcome by exploiting the data of the precision Muon Drift-Tube (MDT) chambers in the first-level trigger decision. This requires continuous fast transfer of the MDT hits to the off-detector trigger logic and fast track reconstruction algorithms. The reduction of the muon trigger rate achievable with the proposed new trigger concept, the performance of a novel fast track reconstruction algorithm, and the first hardware demonstration of the scheme with muon testbeam data taken at the CERN Gamma Irradiation Facility are discussed.
271 - M. Deile , J. Dubbert , S. Horvat 2016
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of up to 990 H z/square cm which corresponds to twice the highest background rate expected in ATLAS. A silicon strip detector telescope was used as external reference in the beam. The pulse-height measurement of the read-out electronics was used to perform time-slewing corrections which lead to an improvement of the average drift-tube resolution from 104 microns to 82 microns without irradiation and from 128 microns to 108 microns at the maximum expected rate. The measured drift-tube efficiency agrees with the expectation from the dead time of the read-out electronics up to the maximum expected rate.
Data sets with high statistics taken at the cosmic ray facility, equipped with 3 ATLAS BOS MDT chambers, in Garching (Munich) have been used to study temperature and pressure effects on gas gain and drifttime. The deformation of a thermally expanded chamber was reconstructed using the internal RasNik alignment monitoring system and the tracks from cosmic data. For these studies a heating system was designed to increase the temperature of the middle chamber by up to 20 Kelvins over room temperature. For comparison the temperature effects on gas properties have been simulated with Garfield. The maximum drifttime decreased under temperature raise by -2.21 +- 0.08 ns/K, in agreement with the results of pressure variations and the Garfield simulation. The increased temperatures led to a linear increase of the gas gain of about 2.1% 1/K. The chamber deformation has been analyzed with the help of reconstructed tracks. By the comparison of the tracks through the reference chambers with these through the test chamber the thermal expansion has been reconstructed and the result shows agreement with the theoretical expansion coefficient. As the wires are fixed at the end of the chamber, the wire position calculation can not provide a conclusion for the chamber middle. The complete deformation has been identified with the analysis of the monitoring system RasNik, whose measured values have shown a homogeneous expansion of the whole chamber, overlayed by a shift and a rotation of the chamber middle with respect to the outer part of the chamber. The established results of both methods are in agreement. We present as well a model for the position-drifttime correction as function of temperature.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا