ﻻ يوجد ملخص باللغة العربية
Data sets with high statistics taken at the cosmic ray facility, equipped with 3 ATLAS BOS MDT chambers, in Garching (Munich) have been used to study temperature and pressure effects on gas gain and drifttime. The deformation of a thermally expanded chamber was reconstructed using the internal RasNik alignment monitoring system and the tracks from cosmic data. For these studies a heating system was designed to increase the temperature of the middle chamber by up to 20 Kelvins over room temperature. For comparison the temperature effects on gas properties have been simulated with Garfield. The maximum drifttime decreased under temperature raise by -2.21 +- 0.08 ns/K, in agreement with the results of pressure variations and the Garfield simulation. The increased temperatures led to a linear increase of the gas gain of about 2.1% 1/K. The chamber deformation has been analyzed with the help of reconstructed tracks. By the comparison of the tracks through the reference chambers with these through the test chamber the thermal expansion has been reconstructed and the result shows agreement with the theoretical expansion coefficient. As the wires are fixed at the end of the chamber, the wire position calculation can not provide a conclusion for the chamber middle. The complete deformation has been identified with the analysis of the monitoring system RasNik, whose measured values have shown a homogeneous expansion of the whole chamber, overlayed by a shift and a rotation of the chamber middle with respect to the outer part of the chamber. The established results of both methods are in agreement. We present as well a model for the position-drifttime correction as function of temperature.
Highly selective first-level triggers are essential to exploit the full physics potential of the ATLAS experiment at High-Luminosity LHC (HL-LHC). The concept for a new muon trigger stage using the precision monitored drift tube (MDT) chambers to sig
Highly selective triggers are essential for the physics programme of the ATLAS experiment at HL-LHC where the instantaneous luminosity will be about an order of magnitude larger than the LHC instantaneous luminosity in Run 1. The first level muon tri
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 C
The influence of fast neutrons on the occupancy and the single tube resolution of ATLAS muon drift detectors was investigated by exposing a chamber built out of 3 layers of 3 short standard drift tubes to neutron flux-densities of up to 16 kHz/cm2 at
A new small-diameter Monitored Drift Tube (sMDT) chamber has been developed for the muon spectrometer of the ATLAS experiment to handle the higher collision rates expected at the CERN High Luminosity Large Hadron Collider (HL-LHC). This paper present