ترغب بنشر مسار تعليمي؟ اضغط هنا

Simple models for dynamic hysteresis loops calculation: Application to hyperthermia optimization

126   0   0.0 ( 0 )
 نشر من قبل Julian Carrey
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

To optimize the heating properties of magnetic nanoparticles (MNPs) in magnetic hyperthermia applications, it is necessary to calculate the area of their hysteresis loops in an alternating magnetic field. The three types of theories suitable for describing the hysteresis loops of MNPs are presented and compared to numerical simulations: equilibrium functions, Stoner-Wohlfarth model based theories (SWMBTs) and linear response theory (LRT). Suitable formulas to calculate the hysteresis area of major cycles are deduced from SWMBTs and from numerical simulations; the domain of validity of the analytical formula is explicitly studied. In the case of minor cycles, the hysteresis area calculations are based on the LRT. A perfect agreement between LRT and numerical simulations of hysteresis loops is obtained. The domain of validity of the LRT is explicitly studied. Formulas to calculate the hysteresis area at low field valid for any anisotropy of the MNP are proposed. Numerical simulations of the magnetic field dependence of the area show it follows power-laws with a large range of exponents. Then, analytical expressions derived from LRT and SWMBTs are used for a theoretical study of magnetic hyperthermia. It is shown that LRT is only pertinent for MNPs with strong anisotropy and that SWMBTs should be used for weak anisotropy MNPs. The optimum volume of MNPs for magnetic hyperthermia as function of material and experimental parameters is derived. The maximum specific absorption rate (SAR) achievable is calculated versus the MNP anisotropy. It is shown that an optimum anisotropy increases the SAR and reduces the detrimental effects of size distribution. The optimum anisotropy is simple to calculate and depends on the magnetic field used in the hyperthermia experiments and on the MNP magnetization only. The theoretical optimum parameters are compared to the one of several magnetic materials.

قيم البحث

اقرأ أيضاً

A low-cost and simple setup for measuring the high-frequency hysteresis loops of magnetic samples is described. An AMF in the range 6-100 kHz with amplitude up to 80 mT is produced by a Litz wire coil. The latter is air-cooled using a forced-air appr oach so no water flow is required to run the setup. High-frequency hysteresis loops are measured using a system of pick-up coils and numerical integration of signals. Reproducible measurements are obtained in the frequency range of 6-56 kHz. Measurement examples on ferrite cylinders and on iron oxide nanoparticle ferrofluids are shown. Comparison with other measurement methods of the hysteresis loop area (complex susceptibility, quasi-static hysteresis loops and calorific measurements) is provided and shows the coherency of the results obtained with this setup. This setup is well adapted to the magnetic characterization of colloidal solutions of MNPs for magnetic hyperthermia applications.
Cumulative growth of successive minor hysteresis loops in Co/Pd multilayers with perpendicular anisotropy was studied in the context of time dependent magnetization reversal dynamics. We show that in disordered ferromagnets, where magnetization rever sal involves nucleation, domains expansion and annihilation, differences between the time dependencies of these processes are responsible for accumulation of nuclei for rapid domain expansion, for the asymmetry of forward and backward magnetization reversals and for the respective cumulative growth of hysteresis loops. Loops stop changing and become macroscopically reproducible when populations of upward and downward nucleation domains balance each other and the respective upward and downward reversal times stabilize.
The influence of a transverse static magnetic field on the magnetic hyperthermia properties is studied on a system of large-losses ferromagnetic FeCo nanoparticles. The simultaneous measurement of the high-frequency hysteresis loops and of the temper ature rise provides an interesting insight into the losses and heating mechanisms. A static magnetic field of only 40 mT is enough to cancel the heating properties of the nanoparticles, a result reproduced using numerical simulations of hysteresis loops. These results cast doubt on the possibility to perform someday magnetic hyperthermia inside a magnetic resonance imaging setup.
For the first time in a bulk proper uniaxial ferroelectrics, double antiferroelectric-like hysteresis loops have been observed in the case of Sn$_2$P$_2$S$_6$ crystal. The quantum anharmonic oscillator model was proposed for description of such polar ization switching process. This phenomenon is related to three-well local potential of spontaneous polarization fluctuations at peculiar negative ratio of coupling constants which correspond to inter-site interaction in given sublattice and interaction between two sublattices of Sn$_2$P$_2$S$_6$ modeled crystal structure. Obtained data can be used for development of triple-level cell type memory technology.
98 - Zhi Ma , Liying Xi , Xuming Wang 2016
In published papers, the Gibbs free energy of ferroelectric materials has usually been quantified by the retention of 6th or 8th order polarization terms. In this paper, a newly analytical model of Gibbs free energy, thereout, a new model of polariza tion-electric field hysteresis loops in ferroelectric materials has been derived mathematically. As a model validation, four patterns of polarization-electric field hysteresis loops of ferroelectric materials have been depicted by using the model. The calculated results indicated that the self-similar model can characterize the various patterns of hysteresis loops in ferroelectric materials through adjusting the external excitation or the synthetically parameter (e.g., electric, temperature, and stress, etc.) employed in the model.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا