ترغب بنشر مسار تعليمي؟ اضغط هنا

Comparative study of different scattering geometries for the proposed Indian X-ray polarization measurement experiment using Geant4

71   0   0.0 ( 0 )
 نشر من قبل Santosh Vadawale
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English
 تأليف S. V. Vadawale




اسأل ChatGPT حول البحث

Polarization measurements in X-rays can provide unique opportunity to study the behavior of matter and radiation under extreme magnetic fields and extreme gravitational fields. Unfortunately, over past two decades, when X-ray astronomy witnessed multiple order of magnitude improvement in temporal, spatial and spectral sensitivities, there is no (or very little) progress in the field of polarization measurements of astrophysical X-rays. Recently, a proposal has been submitted to ISRO for a dedicated small satellite based experiment to carry out X-ray polarization measurement, which aims to provide the first X-ray polarization measurements since 1976. This experiment will be based on the well known principle of polarization measurement by Thomson scattering and employs the baseline design of a central low Z scatterer surrounded by X-ray detectors to measure the angular intensity distribution of the scattered X-rays. The sensitivity of such experiment is determined by the collecting area, scattering and detection efficiency, X-ray detector background, and the modulation factor. Therefore, it is necessary to carefully select the scattering geometry which can provide the highest modulation factor and thus highest sensitivity within the specified experimental constraints. The effective way to determine optimum scattering geometry is by studying various possible scattering geometries by means of Monte Carlo simulations. Here we present results of our detailed comparative study based on Geant4 simulations of five different scattering geometries which can be considered within the weight and size constraints of the proposed small satellite based X-ray polarization measurement experiment.

قيم البحث

اقرأ أيضاً

Low energy protons (< 300 keV) can enter the field of view of X-ray space telescopes, scatter at small incident angles, and deposit energy on the detector, causing intense background flares at the focal plane or in the most extreme cases, damaging th e X-ray detector. A correct modelization of the physics process responsible for the grazing angle scattering processes is mandatory to evaluate the impact of such events on the performance of future X-ray telescopes as the ESA ATHENA mission. For the first time the Remizovich model, in the approximation of no energy losses, is implemented top of the Geant4 release 10.2. Both the new scattering physics and the built-in Coulomb scattering are used to reproduce the latest experimental results on grazing angle proton scattering. At 250 keV multiple scattering delivers large proton angles and it is not consistent with the observation. Among the tested models, the single scattering seems to better reproduce the scattering efficiency at the three energies but energy loss obtained at small scattering angles is significantly lower than the experimental values. In general, the energy losses obtained in the experiment are higher than what obtained by the simulation. The experimental data are not completely representative of the soft proton scattering experienced by current X-ray telescopes because of the lack of measurements at low energies (< 200 keV) and small reflection angles, so we are not able to address any of the tested models as the one that can certainly reproduce the scattering behavior of low energy protons expected for the ATHENA mission. We can, however, discard multiple scattering as the model able to reproduce soft proton funneling, and affirm that Coulomb single scattering can represent, until further measurements, the best approximation of the proton scattered angular distribution at the exit of X-ray optics.
The low energy phonons of two different graphite intercalation compounds (GICs) have been measured as a function of temperature using inelastic x-ray scattering (IXS). In the case of the non-superconductor BaC6, the phonons observed are significantly higher (up to 20 %) in energy than those predicted by theory, in contrast to the reasonable agreement found in superconducting CaC6. Additional IXS intensity is observed below 15 meV in both BaC6 and CaC6. It has been previously suggested that this additional inelastic intensity may arise from defect or vacancy modes in these compounds, unpredicted by theory (dAstuto et al, Phys. Rev. B 81 104519 (2010)). Here it is shown that this additional intensity can arise directly from the large disorder of the available samples. Our results show that future theoretical work is required to understand the relationship between the crystal structure, the phonons and the superconductivity in GICs.
The rapid development of X-ray astronomy has been made possible by widely deploying X-ray focusing telescopes on board many X-ray satellites. Geant4 is a very powerful toolkit for Monte Carlo simulations and has remarkable abilities to model complex geometrical configurations. However, the library of physical processes available in Geant4 lacks a description of the reflection of X-ray photons at a grazing incident angle which is the core physical process in the simulation of X-ray focusing telescopes. The scattering of low-energy charged particles from the mirror surfaces is another noteworthy process which is not yet incorporated into Geant4. Here we describe a Monte Carlo model of a simplified wide-angle X-ray focusing telescope adopting lobster-eye optics and a silicon detector using the Geant4 toolkit. With this model, we simulate the X-ray tracing, proton scattering and background detection. We find that: (1) the effective area obtained using Geant4 is in agreement with that obtained using Q software with an average difference of less than 3%; (2) X-rays are the dominant background source below 10 keV; (3) the sensitivity of the telescope is better by at least one order of magnitude than that of a coded mask telescope with the same physical dimensions; (4) the number of protons passing through the optics and reaching the detector by Firsov scattering is about 2.5 times that of multiple scattering for the lobster-eye telescope.
265 - S. Zane , D. Walton , T. Kennedy 2012
The Large Observatory for X-ray Timing (LOFT) is one of the four candidate ESA M3 missions considered for launch in the 2022 time-frame. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. The LOFT scientific payload is composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a 10 m2-class pointed instrument with 20 times the collecting area of the best past timing missions (such as RXTE) over the 2-30 keV range, which holds the capability to revolutionize studies of X-ray variability down to the millisecond time scales. Its ground-breaking characteristic is a low mass per unit surface, enabling an effective area of ~10 m^2 (@10 keV) at a reasonable weight. The development of such large but light experiment, with low mass and power per unit area, is now made possible by the recent advancements in the field of large-area silicon detectors - able to time tag an X-ray photon with an accuracy <10 {mu}s and an energy resolution of ~260 eV at 6 keV - and capillary-plate X-ray collimators. In this paper, we will summarize the characteristics of the LAD instrument and give an overview of its capabilities.
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in $mathrm{CaWO_4}$ crystals. To understand the CRESST electrom agnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to $(68 pm 16),mathrm{%}$ of the electromagnetic background in the energy range between $1,mathrm{keV}$ and $40,mathrm{keV}$.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا