ترغب بنشر مسار تعليمي؟ اضغط هنا

Quantitative measurement of the magnetic moment of an individual magnetic nanoparticle by magnetic force microscopy

79   0   0.0 ( 0 )
 نشر من قبل Sibylle Sievers
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Kai-Felix Braun




اسأل ChatGPT حول البحث

We demonstrate the quantitative measurement of the magnetization of individual magnetic nanoparticles (MNP) using a magnetic force microscope (MFM). The quantitative measurement is realized by calibration of the MFM signal using an MNP reference sample with traceably determined magnetization. A resolution of the magnetic moment of the order of 10^(-18) Am^2 under ambient conditions is demonstrated which is presently limited by the tips magnetic moment and the noise level of the instrument. The calibration scheme can be applied to practically any MFM and tip thus allowing a wide range of future applications e.g. in nanomagnetism and biotechnology.

قيم البحث

اقرأ أيضاً

We report the quantum calibration of a magnetic force microscope (MFM) by measuring the two-dimensional magnetic stray field distribution of the tip MFM using a single nitrogen vacancy (NV) center in diamond. From the measured stray field distributio n and the mechanical properties of the cantilever a calibration function is derived allowing to convert MFM images in quantum calibrated stray field maps. This novel approach overcomes limitations of prior MFM calibration schemes and allows quantum calibrated nanoscale stray field measurements in a field range inaccessible by scanning NV magnetometry. Quantum calibrated measurements of a stray field reference sample allow its use as a transfer standard opening the road towards fast and easily accessible quantum traceable calibration of virtually any MFM.
Magnetic force microscopy (MFM) measurements generally provide phase images which represent the signature of domain structures on the surface of nanomaterials. To quantitatively determine magnetic stray fields based on an MFM image requires calibrate d properties of the magnetic tip. In this work, an approach is presented for calibrating a magnetic tip using a Co/Pt multilayered film as a reference sample which shows stable well-known magnetic properties and well-defined perpendicular band domains. The approach is based on a regularized deconvolution process in Fourier domain with a Wiener filter and the L-curve method for determining a suitable regularization parameter to get a physically reasonable result. The calibrated tip is applied for a traceable quantitative determination of the stray fields of a test sample which has a patial frequency spectrum covered by that of the reference sample. According to the Guide to the expression of uncertainty in measurement, uncertainties of the processing algorithm are estimated considering the fact that the regularization influences significantly the quantitative analysis. We discuss relevant uncertainty components and their propagations between real domain and Fourier domain for both, the tip calibration procedure and the stray field calculation, and propose an uncertainty evaluation procedure for quantitative magnetic force microscopy.
Magnetic nanoparticles are useful in many medical applications because they interact with biology on a cellular level thus allowing microenvironmental investigation. An enhanced understanding of the dynamics of magnetic particles may lead to advances in imaging directly in magnetic particle imaging (MPI) or through enhanced MRI contrast and is essential for nanoparticle sensing as in magnetic spectroscopy of Brownian motion (MSB). Moreover, therapeutic techniques like hyperthermia require information about particle dynamics for effective, safe, and reliable use in the clinic. To that end, we have developed and validated a stochastic dynamical model of rotating Brownian nanoparticles from a Langevin equation approach. With no field, the relaxation time toward equilibrium matches Einsteins model of Brownian motion. In a static field, the equilibrium magnetization agrees with the Langevin function. For high frequency or low amplitude driving fields, behavior characteristic of the linearized Debye approximation is reproduced. In a higher field regime where magnetic saturation occurs, the magnetization and its harmonics compare well with the effective field model. On another level, the model has been benchmarked against experimental results, successfully demonstrating that harmonics of the magnetization carry enough information to infer environmental parameters like viscosity and temperature.
A single-passage, bimodal magnetic force microscopy technique optimized for scanning samples with arbitrary topography is discussed. A double phase-locked loop (PLL) system is used to mechanically excite a high quality factor cantilever under vacuum conditions on its first mode and via an oscillatory tip-sample potential on its second mode. The obtained second mode oscillation amplitude is then used as a proxy for the tip-sample distance, and for the control thereof. With appropriate $z$-feedback parameters two data sets reflecting the magnetic tip-sample interaction and the sample topography are simultaneously obtained.
118 - Hai Li , Xiaoying Qi , Jumiati Wu 2013
For the first time, the magnetic force microscopy (MFM) is used to characterize the mechanically-exfoliated single- and few-layer MoS2 and graphene nanosheets. By analysis of the phase and amplitude shifts, the magnetic response of MoS2 and graphene nanosheets exhibits the dependence on their layer number. However, the solution-processed single-layer MoS2 nanosheet shows the reverse magnetic signal to the mechanically-exfoliated one, and the graphene oxide nanosheet has not shown any detectable magnetic signal. Importantly, graphene and MoS2 flakes become nonmagnetic when they exceed a certain thickness.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا