Confinement effects in a guided-wave interferometer with millimeter-scale arm separation

78   0   0.0 ( 0 )
 نشر من قبل Charles Sackett
 تاريخ النشر 2007
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Guided-wave atom interferometers measure interference effects using atoms held in a confining potential. In one common implementation, the confinement is primarily two-dimensional, and the atoms move along the nearly free dimension under the influence of an off-resonant standing wave laser beam. In this configuration, residual confinement along the nominally free axis can introduce a phase gradient to the atoms that limits the arm separation of the interferometer. We experimentally investigate this effect in detail, and show that it can be alleviated by having the atoms undergo a more symmetric motion in the guide. This can be achieved by either using additional laser pulses or by allowing the atoms to freely oscillate in the potential. Using these techniques, we demonstrate interferometer measurement times up to 72 ms and arm separations up to 0.42 mm with a well controlled phase, or times of 0.91 s and separations of 1.7 mm with an uncontrolled phase.

قيم البحث

اقرأ أيضاً

We demonstrate the effectiveness of a guided-wave Bose-Einstein condensate interferometer for practical measurements. Taking advantage of the large arm separations obtainable in our interferometer, the energy levels of the 87Rb atoms in one arm of th e interferometer are shifted by a calibrated laser beam. The resulting phase shifts are used to determine the ac polarizability at a range of frequencies near and at the atomic resonance. The measured values are in good agreement with theoretical expectations. However, we observe a broadening of the transition near the resonance, an indication of collective light scattering effects. This nonlinearity may prove useful for the production and control of squeezed quantum states.
A Michelson interferometer using Bose-Einstein condensates is demonstrated with coherence times of up to 44 ms and arm separations up to 0.18 mm. This arm separation is larger than that observed for any previous atom interferometer. The device uses a toms weakly confined in a magnetic guide and the atomic motion is controlled using Bragg interactions with an off-resonant standing wave laser beam.
In this paper we demonstrate a magnetically guided Cesium (Cs) atom interferometer in the Talbot-Lau regime for inertial sensing with two interferometer schemes, Mach-Zenhder and Ramsey-Borde. The recoil frequency of the Cs atoms and the acceleration along the waveguide symmetry axis is measured. An acceleration measurement uncertainty of $7times10^{-5}$ m/s$^{2}$ is achieved. We also realize an enclosed area of $0.018$ mm$^{2}$ for rotation measurement. As the first reported magnetically guided Cs atom interferometer, the system limitation and its advantages are discussed.
We demonstrate phase sensitivity in a horizontally guided, acceleration-sensitive atom interferometer with a momentum separation of 80hk between its arms. A fringe visibility of 7% is observed. Our coherent pulse sequence accelerates the cold cloud i n an optical waveguide, an inherently scalable route to large momentum separation and high sensitivity. We maintain coherence at high momentum separation due to both the transverse confinement provided by the guide, and our use of optical delta-kick cooling on our cold-atom cloud. We also construct a horizontal interferometric gradiometer to measure the longitudinal curvature of our optical waveguide.
We present an underground long baseline atom interferometer to study gravity at large scale. The hybrid atom-laser antenna will use several atom interferometers simultaneously interrogated by the resonant mode of an optical cavity. The instrument wil l be a demonstrator for gravitational wave detection in a frequency band (100 mHz - 1 Hz) not explored by classical ground and space-based observatories, and interesting for potential astrophysical sources. In the initial instrument configuration, standard atom interferometry techniques will be adopted, which will bring to a peak strain sensitivity of 2$cdot 10^{-13}/sqrt{mathrm{Hz}}$ at 2 Hz. The experiment will be realized at the underground facility of the Laboratoire Souterrain `a Bas Bruit (LSBB) in Rustrel--France, an exceptional site located away from major anthropogenic disturbances and showing very low background noise. In the following, we present the measurement principle of an in-cavity atom interferometer, derive signal extraction for Gravitational Wave measurement from the antenna and determine the expected strain sensitivity. We then detail the functioning of the different systems of the antenna and describe the properties of the installation site.