ترغب بنشر مسار تعليمي؟ اضغط هنا

Absolute Calibration and Characterization of the Multiband Imaging Photometer for Spitzer. I. The Stellar Calibrator Sample and the 24 micron Calibration

119   0   0.0 ( 0 )
 نشر من قبل C. W. Engelbracht
 تاريخ النشر 2007
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present the stellar calibrator sample and the conversion from instrumental to physical units for the 24 micron channel of the Multiband Imaging Photometer for Spitzer (MIPS). The primary calibrators are A stars, and the calibration factor based on those stars is 4.54*10^{-2} MJy sr^{-1} (DN/s)^{-1}, with a nominal uncertainty of 2%. We discuss the data-reduction procedures required to attain this accuracy; without these procdures, the calibration factor obtained using the automated pipeline at the Spitzer Science Center is 1.6% +/- 0.6% lower. We extend this work to predict 24 micron flux densities for a sample of 238 stars which covers a larger range of flux densities and spectral types. We present a total of 348 measurements of 141 stars at 24 micron. This sample covers a factor of ~460 in 24 micron flux density, from 8.6 mJy up to 4.0 Jy. We show that the calibration is linear over that range with respect to target flux and background level. The calibration is based on observations made using 3-second exposures; a preliminary analysis shows that the calibration factor may be 1% and 2% lower for 10- and 30-second exposures, respectively. We also demonstrate that the calibration is very stable: over the course of the mission, repeated measurements of our routine calibrator, HD 159330, show a root-mean-square scatter of only 0.4%. Finally, we show that the point spread function (PSF) is well measured and allows us to calibrate extended sources accurately; Infrared Astronomy Satellite (IRAS) and MIPS measurements of a sample of nearby galaxies are identical within the uncertainties.

قيم البحث

اقرأ أيضاً

The absolute calibration and characterization of the Multiband Imaging Photometer for Spitzer (MIPS) 70 micron coarse- and fine-scale imaging modes are presented based on over 2.5 years of observations. Accurate photometry (especially for faint sourc es) requires two simple processing steps beyond the standard data reduction to remove long-term detector transients. Point spread function (PSF) fitting photometry is found to give more accurate flux densities than aperture photometry. Based on the PSF fitting photometry, the calibration factor shows no strong trend with flux density, background, spectral type, exposure time, or time since anneals. The coarse-scale calibration sample includes observations of stars with flux densities from 22 mJy to 17 Jy, on backgrounds from 4 to 26 MJy sr^-1, and with spectral types from B to M. The coarse-scale calibration is 702 +/- 35 MJy sr^-1 MIPS70^-1 (5% uncertainty) and is based on measurements of 66 stars. The instrumental units of the MIPS 70 micron coarse- and fine-scale imaging modes are called MIPS70 and MIPS70F, respectively. The photometric repeatability is calculated to be 4.5% from two stars measured during every MIPS campaign and includes variations on all time scales probed. The preliminary fine-scale calibration factor is 2894 +/- 294 MJy sr^-1 MIPS70F^-1 (10% uncertainty) based on 10 stars. The uncertainty in the coarse- and fine-scale calibration factors are dominated by the 4.5% photometric repeatability and the small sample size, respectively. The 5-sigma, 500 s sensitivity of the coarse-scale observations is 6-8 mJy. This work shows that the MIPS 70 micron array produces accurate, well calibrated photometry and validates the MIPS 70 micron operating strategy, especially the use of frequent stimulator flashes to track the changing responsivities of the Ge:Ga detectors.
The Spectral Energy Distribution (SED) mode of the Multiband Imaging Photometer for Spitzer (MIPS) Space Telescope provides low-spectral resolution (R ~ 15-25) spectroscopy in the far infrared using the MIPS 70 um detector. A reflective grating provi des a dispersion of 1.7 um per pixel, and an effective wavelength coverage of 52.8--98.7 um over detector rows 1-27. The final 5 detector rows are contaminated by second-order diffracted light and are left uncalibrated. The flux calibration is based on observations of MIPS calibration stars with 70 um flux densities of 0.5--15 Jy. The point-source flux calibration accuracy is estimated to be 10% or better down to about 0.5 Jy at the blue end of the spectrum and to 2 Jy near the red end. With additional uncertainties from the illumination and aperture corrections included, the surface brightness calibration of extended sources is accurate to ~15%. Repeatability of better than 5% is found for the SED mode through multiple measurements of several calibration stars.
We describe the absolute calibration of the Multiband Imaging Photometer for Spitzer (MIPS) 160 micron channel. After the on-orbit discovery of a near-IR ghost image that dominates the signal for sources hotter than about 2000 K, we adopted a strateg y utilizing asteroids to transfer the absolute calibrations of the MIPS 24 and 70 micron channels to the 160 micron channel. Near-simultaneous observations at all three wavelengths are taken, and photometry at the two shorter wavelengths is fit using the Standard Thermal Model. The 160 micron flux density is predicted from those fits and compared with the observed 160 micron signal to derive the conversion from instrumental units to surface brightness. The calibration factor we derive is 41.7 MJy/sr/MIPS160 (MIPS160 being the instrumental units). The scatter in the individual measurements of the calibration factor, as well as an assesment of the external uncertainties inherent in the calibration, lead us to adopt an uncertainty of 5.0 MJy/sr/MIPS160 (12%) for the absolute uncertainty on the 160 micron flux density of a particular source as determined from a single measurement. For sources brighter than about 2 Jy, non-linearity in the response of the 160 micron detectors produces an under-estimate of the flux density: for objects as bright as 4 Jy, measured flux densities are likely to be ~20% too low. This calibration has been checked against that of ISO (using ULIRGS) and IRAS (using IRAS-derived diameters), and is consistent with those at the 5% level.
46 - B. Grossan , G. F. Smoot 2006
We describe data reduction and analysis of fluctuations in the cosmic far-IR background (CFIB) in observations with the Multiband Imaging Photometer for Spitzer (MIPS) instrument 160 micron detectors. We analyzed observations of an 8.5 square degree region in the Lockman Hole, part of the largest low-cirrus mapping observation with this instrument. We measured the power spectrum of the CFIB in these observations by fitting a power law to the IR cirrus component, the dominant foreground contaminant, and subtracting this cirrus signal. The CFIB power spectrum in the range 0.2 arc min^{-1} <k< 0.5 arc min^{-1} is consistent with previous measurements of a relatively flat component. However, we find a large power excess at low k, which falls steeply to the flat component in the range 0.03 arc min^{-1} <k< 0.1 arc min^{-1}. This low-k power spectrum excess is consistent with predictions of a source clustering signature. This is the first report of such a detection in the far-IR.
We describe the procedure used to flux calibrate the three-band submillimetre photometer in the Spectral and Photometric Imaging REceiver (SPIRE) instrument on the Herschel Space Observatory. This includes the equations describing the calibration sch eme, a justification for using Neptune as the primary calibration source, a description of the observations and data processing procedures used to derive flux calibration parameters (for converting from voltage to flux density) for every bolometer in each array, an analysis of the error budget in the flux calibration for the individual bolometers, and tests of the flux calibration on observations of primary and secondary calibrators. The procedure for deriving the flux calibration parameters is divided into two parts. In the first part, we use observations of astronomical sources in conjunction with the operation of the photometer internal calibration source to derive the unscaled derivatives of the flux calibration curves. To scale the calibration curves in Jy/beam/V, we then use observations of Neptune in which the beam of each bolometer is mapped using Neptune observed in a very fine scan pattern. The total instrumental uncertainties in the flux calibration for the individual bolometers is ~0.5% for most bolometers, although a few bolometers have uncertainties of ~1-5% because of issues with the Neptune observations. Based on application of the flux calibration parameters to Neptune observations performed using typical scan map observing modes, we determined that measurements from each array as a whole have instrumental uncertainties of 1.5%. This is considerably less than the absolute calibration uncertainty associated with the model of Neptune, which is estimated at 4%.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا