ترغب بنشر مسار تعليمي؟ اضغط هنا

GRAVITY is the second generation Very Large Telescope Interferometer instrument for precision narrow-angle astrometry and interferometric imaging in the Near Infra-Red (NIR). It shall provide precision astrometry of order 10 microarcseconds, and imag ing capability at a few milliarcsecond resolution, and hence will revolutionise dynamical measurements of celestial objects. GRAVITY is currently in the last stages of its integration and tests in Garching at MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present here the instrument, with a particular focus on the components making use of fibres: integrated optics beam combiners, polarisation rotators, fibre differential delay lines, and the metrology.
413 - M. Lippa , N. Blind , S. Gillessen 2015
The VLTI instrument GRAVITY will provide very powerful astrometry by combining the light from four telescopes for two objects simultaneously. It will measure the angular separation between the two astronomical objects to a precision of 10 microarcsec onds. This corresponds to a differential optical path difference (dOPD) between the targets of few nanometers and the paths within the interferometer have to be maintained stable to that level. For this purpose, the novel metrology system of GRAVITY will monitor the internal dOPDs by means of phase-shifting interferometry. We present the four-step phase-shifting concept of the metrology with emphasis on the method used for calibrating the phase shifts. The latter is based on a phase-step insensitive algorithm which unambiguously extracts phases in contrast to other methods that are strongly limited by non-linearities of the phase-shifting device. The main constraint of this algorithm is to introduce a robust ellipse fitting routine. Via this approach we are able to measure phase shifts in the laboratory with a typical accuracy of lambda/2000 or 1 nanometer of the metrology wavelength.
GRAVITY is a new generation beam combination instrument for the VLTI. Its goal is to achieve microarsecond astrometric accuracy between objects separated by a few arcsec. This $10^6$ accuracy on astrometric measurements is the most important challeng e of the instrument, and careful error budget have been paramount during the technical design of the instrument. In this poster, we will focus on baselines induced errors, which is part of a larger error budget.
A basic principle of long baseline interferometry is that an optical path difference (OPD) directly translates into an astrometric measurement. In the simplest case, the OPD is equal to the scalar product between the vector linking the two telescopes and the normalized vector pointing toward the star. However, a too simple interpretation of this scalar product leads to seemingly conflicting results, called here the baseline paradox. For micro-arcsecond accuracy astrometry, we have to model in full the metrology measurement. It involves a complex system subject to many optical effects: from pure baseline errors to static, quasi-static and high order optical aberrations. The goal of this paper is to present the strategy used by the General Relativity Analysis via VLT InTerferometrY instrument (GRAVITY) to minimize the biases introduced by these defects. It is possible to give an analytical formula on how the baselines and tip-tilt errors affect the astrometric measurement. This formula depends on the limit-points of three type of baselines: the wide-angle baseline, the narrow-angle baseline, and the imaging baseline. We also, numerically, include non-common path higher-order aberrations, whose amplitude were measured during technical time at the Very Large Telescope Interferometer. We end by simulating the influence of high-order common-path aberrations due to atmospheric residuals calculated from a Monte-Carlo simulation tool for Adaptive optics systems. The result of this work is an error budget of the biases caused by the multiple optical imperfections, including optical dispersion. We show that the beam stabilization through both focal and pupil tracking is crucial to the GRAVITY system. Assuming the instrument pupil is stabilized at a 4 cm level on M1, and a field tracking below 0.2$lambda/D$, we show that GRAVITY will be able to reach its objective of 10$mu$as accuracy.
GRAVITY is a second generation VLTI instrument, combining the light of four telescopes and two objects simultaneously. The main goal is to obtain astrometrically accurate information. Besides correctly measured stellar phases this requires the knowle dge of the instrumental differential phase, which has to be measured optically during the astronomical observations. This is the purpose of a dedicated metrology system. The GRAVITY metrology covers the full optical path, from the beam combiners up to the reference points in the beam of the primary telescope mirror, minimizing the systematic uncertainties and providing a proper baseline in astrometric terms. Two laser beams with a fixed phase relation travel backward the whole optical chain, creating a fringe pattern in any plane close to a pupil. By temporal encoding the phase information can be extracted at any point by means of flux measurements with photo diodes. The reference points chosen sample the pupil at typical radii, eliminating potential systematics due differential focus. We present the final design and the performance estimate, which is in accordance with the overall requirements for GRAVITY.
We present new observations of the recently discovered gas cloud G2 currently falling towards the massive black hole in the Galactic Center. The new data confirm that G2 is on a highly elliptical orbit with a predicted pericenter passage mid 2013. Th e updated orbit has an even larger eccentricity of 0.966, an epoch of pericenter two months later than estimated before, and a nominal minimum distance of 2200 Schwarzschild radii only. The velocity gradient of G2 has developed further to 600 km/s FWHM in summer 2012. We also detect the tail of similar total flux and on the same orbit as G2 along the trajectory at high significance. No hydrodynamic effects are detected yet, since the simple model of a tidally shearing gas cloud still describes the data very well. The flux of G2 has not changed by more than 10% between 2008 and 2012, disfavoring models where additional gas from a reservoir is released to the disrupting diffuse gas component.
Measurements of stellar orbits provide compelling evidence that the compact radio source Sagittarius A* at the Galactic Centre is a black hole four million times the mass of the Sun. With the exception of modest X-ray and infrared flares, Sgr A* is s urprisingly faint, suggesting that the accretion rate and radiation efficiency near the event horizon are currently very low. Here we report the presence of a dense gas cloud approximately three times the mass of Earth that is falling into the accretion zone of Sgr A*. Our observations tightly constrain the clouds orbit to be highly eccentric, with an innermost radius of approach of only ~3,100 times the event horizon that will be reached in 2013. Over the past three years the cloud has begun to disrupt, probably mainly through tidal shearing arising from the black holes gravitational force. The clouds dynamic evolution and radiation in the next few years will probe the properties of the accretion flow and the feeding processes of the super-massive black hole. The kilo-electronvolt X-ray emission of Sgr A* may brighten significantly when the cloud reaches pericentre. There may also be a giant radiation flare several years from now if the cloud breaks up and its fragments feed gas into the central accretion zone.
In this paper we examine properties of the variable source Sgr A* in the near-infrared (NIR) using a very extensive Ks-band data set from NACO/VLT observations taken 2004 to 2009. We investigate the variability of Sgr A* with two different photometri c methods and analyze its flux distribution. We find Sgr A* is continuously emitting and continuously variable in the near-infrared, with some variability occurring on timescales as long as weeks. The flux distribution can be described by a lognormal distribution at low intrinsic fluxes (<~5 mJy, dereddened with A_{Ks}=2.5). The lognormal distribution has a median flux of approximately 1.1 mJy, but above 5 mJy the flux distribution is significantly flatter (high flux events are more common) than expected for the extrapolation of the lognormal distribution to high fluxes. We make a general identification of the low level emission above 5 mJy as flaring emission and of the low level emission as the quiescent state. We also report here the brightest Ks-band flare ever observed (from August 5th, 2008) which reached an intrinsic Ks-band flux of 27.5 mJy (m_{Ks}=13.5). This flare was a factor 27 increase over the median flux of Sgr A*, close to double the brightness of the star S2, and 40% brighter than the next brightest flare ever observed from Sgr~A*.
GRAVITY is an adaptive optics assisted Beam Combiner for the second generation VLTI instrumentation. The instrument will provide high-precision narrow-angle astrometry and phase-referenced interferometric imaging in the astronomical K-band for faint objects. We describe the wide range of science that will be tackled with this instrument, highlighting the unique capabilities of the VLTI in combination with GRAVITY. The most prominent goal is to observe highly relativistic motions of matter close to the event horizon of Sgr A*, the massive black hole at center of the Milky Way. We present the preliminary design that fulfils the requirements that follow from the key science drivers: It includes an integrated optics, 4-telescope, dual feed beam combiner operated in a cryogenic vessel; near-infrared wavefrontsensing adaptive optics; fringe-tracking on secondary sources within the field of view of the VLTI and a novel metrology concept. Simulations show that 10 {mu}as astrometry within few minutes is feasible for a source with a magnitude of mK = 15 like Sgr A*, given the availability of suitable phase reference sources (mK = 10). Using the same setup, imaging of mK = 18 stellar sources in the interferometric field of view is possible, assuming a full night of observations and the corresponding UV coverage of the VLTI.
The center of the Milky Way hosts a massive black hole. The observational evidence for its existence is overwhelming. The compact radio source Sgr A* has been associated with a black hole since its discovery. In the last decade, high-resolution, near -infrared measurements of individual stellar orbits in the innermost region of the Galactic Center have shown that at the position of Sgr A* a highly concentrated mass of 4 x 10^6 M_sun is located. Assuming that general relativity is correct, the conclusion that Sgr A* is a massive black hole is inevitable. Without doubt this is the most important application of stellar orbits in the Galactic Center. Here, we discuss the possibilities going beyond the mass measurement offered by monitoring these orbits. They are an extremely useful tool for many scientific questions, such as a geometric distance estimate to the Galactic Center or the puzzle, how these stars reached their current orbits. Future improvements in the instrumentation will open up the route to testing relativistic effects in the gravitational potential of the black hole, allowing to take full advantage of this unique laboratory for celestial mechanics.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا