ترغب بنشر مسار تعليمي؟ اضغط هنا

Recent efforts have applied quantum tomography techniques to the calibration and characterization of complex quantum detectors using minimal assumptions. In this work we provide detail and insight concerning the formalism, the experimental and theore tical challenges and the scope of these tomographical tools. Our focus is on the detection of photons with avalanche photodiodes and photon number resolving detectors and our approach is to fully characterize the quantum operators describing these detectors with a minimal set of well specified assumptions. The formalism is completely general and can be applied to a wide range of detectors
Measurement is the only part of a general quantum system that has yet to be characterized experimentally in a complete manner. Detector tomography provides a procedure for doing just this; an arbitrary measurement device can be fully characterized, a nd thus calibrated, in a systematic way without access to its components or its design. The result is a reconstructed POVM containing the measurement operators associated with each measurement outcome. We consider two detectors, a single-photon detector and a photon-number counter, and propose an easily realized experimental apparatus to perform detector tomography on them. We also present a method of visualizing the resulting measurement operators.
Measurement connects the world of quantum phenomena to the world of classical events. It plays both a passive role, observing quantum systems, and an active one, preparing quantum states and controlling them. Surprisingly - in the light of the centra l status of measurement in quantum mechanics - there is no general recipe for designing a detector that measures a given observable. Compounding this, the characterization of existing detectors is typically based on partial calibrations or elaborate models. Thus, experimental specification (i.e. tomography) of a detector is of fundamental and practical importance. Here, we present the realization of quantum detector tomography: we identify the optimal positive-operator-valued measure describing the detector, with no ancillary assumptions. This result completes the triad, state, process, and detector tomography, required to fully specify an experiment. We characterize an avalanche photodiode and a photon number resolving detector capable of detecting up to eight photons. This creates a new set of tools for accurately detecting and preparing non-classical light.
Even-order dispersion cancellation, an effect previously identified with frequency-entangled photons, is demonstrated experimentally for the first time with a linear, classical interferometer. A combination of a broad bandwidth laser and a high resol ution spectrometer was used to measure the intensity correlations between anti-correlated optical frequencies. Only 14% broadening of the correlation signal is observed when significant material dispersion, enough to broaden the regular interferogram by 4250%, is introduced into one arm of the interferometer.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا