ترغب بنشر مسار تعليمي؟ اضغط هنا

We report a new measurement of electron antineutrino disappearance using the fully-constructed Daya Bay Reactor Neutrino Experiment. The final two of eight antineutrino detectors were installed in the summer of 2012. Including the 404 days of data co llected from October 2012 to November 2013 resulted in a total exposure of 6.9$times$10$^5$ GW$_{rm th}$-ton-days, a 3.6 times increase over our previous results. Improvements in energy calibration limited variations between detectors to 0.2%. Removal of six $^{241}$Am-$^{13}$C radioactive calibration sources reduced the background by a factor of two for the detectors in the experimental hall furthest from the reactors. Direct prediction of the antineutrino signal in the far detectors based on the measurements in the near detectors explicitly minimized the dependence of the measurement on models of reactor antineutrino emission. The uncertainties in our estimates of $sin^{2}2theta_{13}$ and $|Delta m^2_{ee}|$ were halved as a result of these improvements. Analysis of the relative antineutrino rates and energy spectra between detectors gave $sin^{2}2theta_{13} = 0.084pm0.005$ and $|Delta m^{2}_{ee}|= (2.42pm0.11) times 10^{-3}$ eV$^2$ in the three-neutrino framework.
This manuscript is a short summary of my talk given at ICNFP2014 Conference. Here we report on new results of $sin^22theta_{13}$ and $Delta m^2_text{ee}$ measurements, search for the sterile neutrino within $10^{-3} text{ eV}^2 <Delta m^2_{41}<0.1tex t{ eV}^2$ domain and precise measurement of the reactor absolute antineutrino flux.
A new measurement of the $theta_{13}$ mixing angle has been obtained at the Daya Bay Reactor Neutrino Experiment via the detection of inverse beta decays tagged by neutron capture on hydrogen. The antineutrino events for hydrogen capture are distinct from those for gadolinium capture with largely different systematic uncertainties, allowing a determination independent of the gadolinium-capture result and an improvement on the precision of $theta_{13}$ measurement. With a 217-day antineutrino data set obtained with six antineutrino detectors and from six 2.9 GW$_{th}$ reactors, the rate deficit observed at the far hall is interpreted as $sin^22theta_{13}=0.083pm0.018$ in the three-flavor oscillation model. When combined with the gadolinium-capture result from Daya Bay, we obtain $sin^22theta_{13}=0.089pm0.008$ as the final result for the six-antineutrino-detector configuration of the Daya Bay experiment.
A measurement of the energy dependence of antineutrino disappearance at the Daya Bay Reactor Neutrino Experiment is reported. Electron antineutrinos ($overline{ u}_{e}$) from six $2.9$ GW$_{rm th}$ reactors were detected with six detectors deployed i n two near (effective baselines 512 m and 561 m) and one far (1579 m) underground experimental halls. Using 217 days of data, 41589 (203809 and 92912) antineutrino candidates were detected in the far hall (near halls). An improved measurement of the oscillation amplitude $sin^{2}2theta_{13} = 0.090^{+0.008}_{-0.009} $ and the first direct measurement of the $overline{ u}_{e}$ mass-squared difference $|Delta m^{2}_{ee}|= (2.59_{-0.20}^{+0.19}) times 10^{-3} {rm eV}^2 $ is obtained using the observed $overline{ u}_{e}$ rates and energy spectra in a three-neutrino framework. This value of $|Delta m^{2}_{ee}|$ is consistent with $|Delta m^{2}_{mumu}|$ measured by muon neutrino disappearance, supporting the three-flavor oscillation model.
118 - Hanyu Wei 2013
Providing an early warning of a galactic supernova using neutrino signals is of importance in studying both supernova dynamics and neutrino physics. The Daya Bay reactor neutrino experiment, with a unique feature of multiple liquid scintillator detec tors separated in space, is sensitive to the full energy spectrum of supernova burst electron-antineutrinos. By deploying 8 Antineutrino Detectors (ADs) in three different experimental halls, we obtain a more powerful and prompt rejection of muon spallation background than single-detector experiments. A dedicated supernova online trigger system embedded in the data acquisition system has been installed to allow the detection of a coincidence of neutrino signals within a 10-second window, thus providing a robust early warning of a supernova occurrence within the Milky Way.
This presentation describes a measurement of the neutrino mixing parameter, sin^2(2theta_13), from the Daya Bay Reactor Neutrino Experiment. Disappearance of electron antineutrinos at a distance of ~2 km from a set of six reactors, where the reactor flux is constrained by near detectors, has been clearly observed. The result, based on the ratio of observed to expected rate of antineutrinos, using 139 days of data taken between December 24, 2011 and May 11, 2012, is sin^2(2theta_13) = 0.089 +/- 0.010(stat.) +/- 0.005(syst.). Improvements in sensitivity from inclusion of additional data, spectral analysis, and improved calibration are expected in the future.
In 2012 the Daya Bay experiment made an unambiguous observation of reactor antineutrino disappearance over kilometer-long baselines and determined that the neutrino mixing angle $theta_{13}$ is non-zero. The measurements of Daya Bay have provided the most precise determination of $theta_{13}$ to date. This whitepaper outlines the prospects for precision studies of reactor antineutrinos at Daya Bay in the coming years. This includes precision measurements of sin$^2 2theta_{13}$ and $Delta m^2_{ee}$ to $<$3%, high-statistics measurement of reactor flux and spectrum, and non-standard physics searches.
131 - David M. Webber 2012
The theory of neutrino oscillations explains changes in neutrino flavor, count rates, and spectra from solar, atmospheric, accelerator, and reactor neutrinos. These oscillations are characterized by three mixing angles and two mass-squared difference s. The solar mixing angle, {theta}_12, and the atmospheric mixing angle, {theta}_23, have been well measured, but until recently the neutrino mixing angle {theta}_13 was not well known. The Daya Bay experiment, located northeast of Hong Kong at the Guangdong Nuclear Power Complex in China, has made a precise measurement of electron antineutrino disappearance using six functionally-identical gadolinium-doped liquid scintillator-based detectors at three sites with distances between 364 and 1900 meters from six reactor cores. This proceeding describes the Daya Bay updated result, using 127 days of good run time collected between December 24, 2011 and May 11, 2012. For the far site, the ratio of the observed number of events to the expected number of events assuming no neutrino oscillation is 0.944 +/- 0.007(stat) +/- 0.003(syst). A fit for {theta}_13 in the three-neutrino framework yields sin^2 2{theta}_13 = 0.089 +/- 0.010(stat) +/- 0.005(syst).
We report an improved measurement of the neutrino mixing angle $theta_{13}$ from the Daya Bay Reactor Neutrino Experiment. We exclude a zero value for $sin^22theta_{13}$ with a significance of 7.7 standard deviations. Electron antineutrinos from six reactors of 2.9 GW$_{rm th}$ were detected in six antineutrino detectors deployed in two near (flux-weighted baselines of 470 m and 576 m) and one far (1648 m) underground experimental halls. Using 139 days of data, 28909 (205308) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to the expected number of antineutrinos assuming no oscillations at the far hall is $0.944pm 0.007({rm stat.}) pm 0.003({rm syst.})$. An analysis of the relative rates in six detectors finds $sin^22theta_{13}=0.089pm 0.010({rm stat.})pm0.005({rm syst.})$ in a three-neutrino framework.
The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle $theta_{13}$ with a sensitivity better than 0.01 in the parameter sin$^22theta_{13}$ at the 90% confidence level. To achieve this goal, the collabor ation will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimental Hall 1, with steady data-taking beginning September 23, 2011. A comparison of the data collected over the subsequent three months indicates that the detectors are functionally identical, and that detector-related systematic uncertainties exceed requirements.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا