Do you want to publish a course? Click here

Interpretable Fault Detection using Projections of Mutual Information Matrix

90   0   0.0 ( 0 )
 Added by Shujian Yu
 Publication date 2020
and research's language is English




Ask ChatGPT about the research

This paper presents a novel mutual information (MI) matrix based method for fault detection. Given a $m$-dimensional fault process, the MI matrix is a $m times m$ matrix in which the $(i,j)$-th entry measures the MI values between the $i$-th dimension and the $j$-th dimension variables. We introduce the recently proposed matrix-based Renyis $alpha$-entropy functional to estimate MI values in each entry of the MI matrix. The new estimator avoids density estimation and it operates on the eigenspectrum of a (normalized) symmetric positive definite (SPD) matrix, which makes it well suited for industrial process. We combine different orders of statistics of the transformed components (TCs) extracted from the MI matrix to constitute the detection index, and derive a simple similarity index to monitor the changes of characteristics of the underlying process in consecutive windows. We term the overall methodology projections of mutual information matrix (PMIM). Experiments on both synthetic data and the benchmark Tennessee Eastman process demonstrate the interpretability of PMIM in identifying the root variables that cause the faults, and its superiority in detecting the occurrence of faults in terms of the improved fault detection rate (FDR) and the lowest false alarm rate (FAR). The advantages of PMIM is also less sensitive to hyper-parameters. The advantages of PMIM is also less sensitive to hyper-parameters. Code of PMIM is available at https://github.com/SJYuCNEL/Fault_detection_PMIM



rate research

Read More

122 - Yuxiao Liu , Ning Zhang , Dan Wu 2020
Power system cascading failures become more time variant and complex because of the increasing network interconnection and higher renewable energy penetration. High computational cost is the main obstacle for a more frequent online cascading failure search, which is essential to improve system security. In this work, we show that the complex mechanism of cascading failures can be well captured by training a graph convolutional network (GCN) offline. Subsequently, the search of cascading failures can be significantly accelerated with the aid of the trained GCN model. We link the power network topology with the structure of the GCN, yielding a smaller parameter space to learn the complex mechanism. We further enable the interpretability of the GCN model by a layer-wise relevance propagation (LRP) algorithm. The proposed method is tested on both the IEEE RTS-79 test system and Chinas Henan Province power system. The results show that the GCN guided method can not only accelerate the search of cascading failures, but also reveal the reasons for predicting the potential cascading failures.
250 - K. Y. Ng , E. Frisk , 2020
This paper presents a method to enhance fault isolation without adding physical sensors on a turbocharged spark ignited petrol engine system by designing additional residuals from an initial observer-based residuals setup. The best candidates from all potential additional residuals are selected using the concept of sequential residual generation to ensure best fault isolation performance for the least number of additional residuals required. A simulation testbed is used to generate realistic engine data for the design of the additional residuals and the fault isolation performance is verified using structural analysis method.
This paper deals with the fault detection and isolation (FDI) problem for linear structured systems in which the system matrices are given by zero/nonzero/arbitrary pattern matrices. In this paper, we follow a geometric approach to verify solvability of the FDI problem for such systems. To do so, we first develop a necessary and sufficient condition under which the FDI problem for a given particular linear time-invariant system is solvable. Next, we establish a necessary condition for solvability of the FDI problem for linear structured systems. In addition, we develop a sufficient algebraic condition for solvability of the FDI problem in terms of a rank test on an associated pattern matrix. To illustrate that this condition is not necessary, we provide a counterexample in which the FDI problem is solvable while the condition is not satisfied. Finally, we develop a graph-theoretic condition for the full rank property of a given pattern matrix, which leads to a graph-theoretic condition for solvability of the FDI problem.
116 - Nan Chen , Miao Wang , Ning Zhang 2020
The connected vehicle paradigm empowers vehicles with the capability to communicate with neighboring vehicles and infrastructure, shifting the role of vehicles from a transportation tool to an intelligent service platform. Meanwhile, the transportation electrification pushes forward the electric vehicle (EV) commercialization to reduce the greenhouse gas emission by petroleum combustion. The unstoppable trends of connected vehicle and EVs transform the traditional vehicular system to an electric vehicular network (EVN), a clean, mobile, and safe system. However, due to the mobility and heterogeneity of the EVN, improper management of the network could result in charging overload and data congestion. Thus, energy and information management of the EVN should be carefully studied. In this paper, we provide a comprehensive survey on the deployment and management of EVN considering all three aspects of energy flow, data communication, and computation. We first introduce the management framework of EVN. Then, research works on the EV aggregator (AG) deployment are reviewed to provide energy and information infrastructure for the EVN. Based on the deployed AGs, we present the research work review on EV scheduling that includes both charging and vehicle-to-grid (V2G) scheduling. Moreover, related works on information communication and computing are surveyed under each scenario. Finally, we discuss open research issues in the EVN.
In this paper, a wide-area measurement system (WAMS)-based method is proposed to estimate the system state matrix for AC system with integrated voltage source converters (VSCs) and identify the electromechanical modes. The proposed method is purely model-free, requiring no knowledge of accurate network topology and system parameters. Numerical studies in the IEEE 68-bus system with integrated VSCs show that the proposed measurementbased method can accurately identify the electromechanical modes and estimate the damping ratios, the mode shapes, and the participation factors. The work may serve as a basis for developing WAMS-based damping control using VSCs in the future.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا