No Arabic abstract
Imperfections in integrated photonics manufacturing have a detrimental effect on the maximal achievable visibility in interferometric architectures. These limits have profound implications for further photonics technological developments and in particular for quantum photonics technologies. Active optimisation approaches, together with reconfigurable photonics, have been proposed as a solution to overcome this. In this paper, we demonstrate an ultra-high (>60 dB) extinction ratio in a silicon photonic device consisting of cascaded Mach-Zehnder interferometers, in which additional interferometers function as variable beamsplitters. The imperfections of fabricated beamsplitters are compensated using an automated progressive optimization algorithm with no requirement for pre-calibration. This work shows the possibility of integrating and accurately controlling linear-optical components for large-scale quantum information processing and other applications.
The recent development of dynamic single-electron sources makes it possible to observe and manipulate the quantum properties of individual charge carriers in mesoscopic circuits. Here, we investigate multi-particle effects in an electronic Mach-Zehnder interferometer driven by dynamic voltage pulses. To this end, we employ a Floquet scattering formalism to evaluate the interference current and the visibility in the outputs of the interferometer. An injected multi-particle state can be described by its first-order correlation function, which we decompose into a sum of elementary correlation functions that each represent a single particle. Each particle in the pulse contributes independently to the interference current, while the visibility (determined by the maximal interference current) exhibits a Fraunhofer-like diffraction pattern caused by the multi-particle interference between different particles in the pulse. For a sequence of multi-particle pulses, the visibility resembles the diffraction pattern from a grid, with the role of the grid and the spacing between the slits being played by the pulses and the time delay between them. Our findings may be observed in future experiments by injecting multi-particle pulses into an electronic Mach-Zehnder interferometer.
We have constructed an atom interferometer of the Mach-Zehnder type, operating with a supersonic beam of lithium. Atom diffraction uses Bragg diffraction on laser standing waves. With first order diffraction, our apparatus has given a large signal and a very good fringe contrast (74%), which we believe to be the highest ever observed with atom interferometers. This apparatus will be applied to high sensitivity measurements
All-optical switching increasingly plays an important role in optical information processing. However, simultaneous achievement of ultralow power consumption, broad bandwidth and high extinction ratio remains challenging. We experimentally demonstrate an ultralow-power all-optical switching by exploiting chiral interaction between light and optically active material in a Mach-Zehnder interferometer (MZI). We achieve switching extinction ratio of 20.0(3.8) and 14.7(2.8) dB with power cost of 66.1(0.7) and 1.3(0.1) fJ/bit, respectively. The bandwidth of our all-optical switching is about 4.2 GHz. Our theoretical analysis shows that the switching bandwidth can, in principle, exceed 110 GHz. Moreover, the switching has the potential to be operated at few-photon level. Our all-optical switching exploits a chiral MZI made of linear optical components. It excludes the requisite of high-quality optical cavity or large optical nonlinearity, thus greatly simplifying realization. Our scheme paves the way towards ultralow-power and ultrafast all-optical information processing.
Possible paths of a photon passing through a nested Mach-Zehnder interferometer on its way to a detector are analyzed using the consistent histories formulation of quantum mechanics, and confirmed using a set of weak measurements (but not weak values). The results disagree with an analysis by Vaidman [ Phys. Rev. A 87 (2013) 052104 ], and agree with a conclusion reached by Li et al. [ Phys. Rev. A 88 (2013) 046102 ]. However, the analysis casts serious doubt on the claim of Salih et al. (whose authorship includes Li et al.) [ Phys. Rev. Lett. 110 (2013) 170502 ] to have constructed a protocol for counterfactual communication: a channel which can transmit information even though it contains a negligible number of photons.
We consider an oscillating micromirror replacing one of the two fixed mirrors of a Mach-Zehnder interferometer. In this ideal optical set-up the quantum oscillator is subjected to the radiation pressure interaction of travelling light waves, no cavity is involved. This configuration shows that squeezed light can be generated by pure scattering on a quantum system, without involving a cavity. The squeezing can be detected at the output ports of the interferometer either by direct detection or by measuring the spectrum of the difference current. We use the Hudson-Parthasarathy equation to model the global evolution. It can describe the scattering of photons and the resulting radiation pressure interaction on the quantum oscillator. It allows to consider also the interaction with a thermal bath. In this way we have a unitary dynamics giving the evolution of oscillator and fields. The Bose fields of quantum stochastic calculus and the related generalized Weyl operators allow to describe the whole optical circuit. By working in the Heisenberg picture, the quantum Langevin equations for position and momentum and the output fields arise, which are used to describe the monitoring in continuous time of the light at the output ports. In the case of strong laser and weak radiation pressure interaction highly non-classical light is produced, and this can be revealed either by direct detection (a negative Mandel Q-parameter is found), either by the intensity spectrum of the difference current of two photodetector; in the second case a nearly complete cancellation of the shot noise can be reached. In this last case it appears that the Mach-Zehnder configuration together with the detection of the difference current corresponds to an homodyne detection scheme, so that we can say that the apparatus is measuring the spectrum of squeezing.