Do you want to publish a course? Click here

High-Resolution Scanning Tunneling Microscopy Imaging of Mesoscopic Graphene Sheets on an Insulating Surface

284   0   0.0 ( 0 )
 Added by Elena Stolyarova Y
 Publication date 2007
  fields Physics
and research's language is English




Ask ChatGPT about the research

We present scanning tunneling microscopy (STM) images of single-layer graphene crystals examined under ultrahigh vacuum conditions. The samples, with lateral dimensions on the micron scale, were prepared on a silicon dioxide surface by direct exfoliation of single crystal graphite. The single-layer films were identified using Raman spectroscopy. Topographic images of single-layer samples display the honeycomb structure expected for the full hexagonal symmetry of an isolated graphene monolayer. The absence of observable defects in the STM images is indicative of the high quality of these films. Crystals comprised of a few layers of graphene were also examined. They exhibited dramatically different STM topography, displaying the reduced three-fold symmetry characteristic of the surface of bulk graphite.



rate research

Read More

116 - P. Mallet , I. Brihuega , S. Bose 2012
Pseudospin, an additional degree of freedom related to the honeycomb structure of graphene, is responsible of many of the outstanding electronic properties found in this material. This article provides a clear understanding of how such pseudospin impacts the quasiparticle interferences of monolayer (ML) and bilayer (BL) graphene measured by low temperature scanning tunneling microscopy and spectroscopy. We have used this technique to map, with very high energy and space resolution, the spatial modulations of the local density of states of ML and BL graphene epitaxialy grown on SiC(0001), in presence of native disorder. We perform a Fourier transform analysis of such modulations including wavevectors up to unit-vectors of the reciprocal lattice. Our data demonstrate that the quasiparticle interferences associated to some particular scattering processes are suppressed in ML graphene, but not in BL graphene. Most importantly, interferences with 2qF wavevector associated to intravalley backscattering are not measured in ML graphene, even on the images with highest resolution. In order to clarify the role of the pseudospin on the quasiparticle interferences, we use a simple model which nicely captures the main features observed on our data. The model unambiguously shows that graphenes pseudospin is responsible for such suppression of quasiparticle interferences features in ML graphene, in particular for those with 2qF wavevector. It also confirms scanning tunneling microscopy as a unique technique to probe the pseudospin in graphene samples in real space with nanometer precision. Finally, we show that such observations are robust with energy and obtain with great accuracy the dispersion of the pi-bands for both ML and BL graphene in the vicinity of the Fermi level, extracting their main tight binding parameters.
We have performed the most realistic simulation to date of the operation of a scanning tunneling microscope. Probe-sample distances from beyond tunneling to actual surface contact are covered. We simultaneously calculate forces, atomic displacements, and tunneling currents, allowing quantitative comparison with experimental values. A distance regime below which the probe becomes unstable is identified. It is shown that the real distance differs substantially from previous estimates because of large atomic displacements on the surface and at the probe-tip.
Defects play a key role in determining the properties of most materials and, because they tend to be highly localized, characterizing them at the single-defect level is particularly important. Scanning tunneling microscopy (STM) has a history of imaging the electronic structure of individual point defects in conductors, semiconductors, and ultrathin films, but single-defect electronic characterization at the nanometer-scale remains an elusive goal for intrinsic bulk insulators. Here we report the characterization and manipulation of individual native defects in an intrinsic bulk hexagonal boron nitride (BN) insulator via STM. Normally, this would be impossible due to the lack of a conducting drain path for electrical current. We overcome this problem by employing a graphene/BN heterostructure, which exploits graphenes atomically thin nature to allow visualization of defect phenomena in the underlying bulk BN. We observe three different defect structures that we attribute to defects within the bulk insulating boron nitride. Using scanning tunneling spectroscopy (STS), we obtain charge and energy-level information for these BN defect structures. In addition to characterizing such defects, we find that it is also possible to manipulate them through voltage pulses applied to our STM tip.
Many atomically thin exfoliated 2D materials degrade when exposed to ambient conditions. They can be protected and investigated by means of transport and optical measurements if they are encapsulated between chemically inert single layers in the controlled atmosphere of a glove box. Here, we demonstrate that the same encapsulation procedure is also compatible with scanning tunneling microscopy (STM) and spectroscopy (STS). To this end, we report a systematic STM/STS investigation of a model system consisting of an exfoliated 2H-NbSe2 crystal capped with a protective 2H-MoS2 monolayer. We observe different electronic coupling between MoS2 and NbSe2, from a strong coupling when their lattices are aligned within a few degrees to 2 essentially no coupling for 30{deg} misaligned layers. We show that STM always probes intrinsic NbSe2 properties such as the superconducting gap and charge density wave at low temperature when setting the tunneling bias inside the MoS2 band gap, irrespective of the relative angle between the NbSe2 and MoS2 lattices. This study demonstrates that encapsulation is fully compatible with STM/STS investigations of 2D materials.
145 - Y. P. Pan , J. J. Zhu , Y. Feng 2021
Scanning superconducting quantum interference device microscopy (sSQUID) is currently one of the most effective methods for direct and sensitive magnetic flux imaging on the mesoscopic scale. A SQUID-on-chip design allows integration of field coils for susceptometry in a gradiometer setup which is very desirable for measuring magnetic responses of quantum matter. However, the spatial resolution of such a design has largely been limited to micrometers due to the difficulty in approaching the sample. Here, we used electron beam lithography technology in the fabrication of the 3D nano-bridge-based SQUID devices to prepare pick-up coils with diameters down to 150 nm. Furthermore, we integrated the deep silicon etching process in order to minimize the distance between the pick-up coil and the wafer edge. Combined with a tuning-fork-based scanning head, the sharpness of the etched chip edge enables a precision of 5 nm in height control. By scanning measurements on niobium chessboard samples using these improved SQUID devices, we demonstrate sub-micron spatial resolutions in both magnetometry and susceptometry, significantly better than our previous generations of nano-SQUIDs. Such improvement in spatial resolution of SQUID-on-chip is a valuable progress for magnetic imaging of quantum materials and devices in various modes.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا