A Quantitative Model for Optical Coherence Tomography

228   0   0.0 ( 0 )
 Added by Leonidas Mindrinos
 Publication date 2021
  fields Physics
and research's language is English




Ask ChatGPT about the research

Optical coherence tomography (OCT) is a widely used imaging technique in the micrometer regime, which gained accelerating interest in medical imaging %and material testing in the last twenty years. In up-to-date OCT literature [5,6] certain simplifying assumptions are made for the reconstructions, but for many applications a more realistic description of the OCT imaging process is of interest. In mathematical models, for example, the incident angle of light onto the sample is usually neglected or %although having a huge impact on the laser power inside the sample is usually neglected or a plane wave description for the light-sample interaction in OCT is used, which ignores almost completely the occurring effects within an OCT measurement process. In this article, we make a first step to a quantitative model by considering the measured intensity as a combination of back-scattered Gaussian beams affected by the system. In contrast to the standard plane wave simplification, the presented model includes system relevant parameters such as the position of the focus and the spot size of the incident laser beam, which allow a precise prediction of the OCT data and therefore ultimately serves as a forward model. The accuracy of the proposed model - after calibration of all necessary system parameters - is illustrated by simulations and validated by a comparison with experimental data obtained from a 1300nm swept-source OCT system.



rate research

Read More

58 - F. Troiani , K. Nikolic , 2017
We present a finite difference time domain (FDTD) model for computation of A line scans in time domain optical coherence tomography (OCT). By simulating only the end of the two arms of the interferometer and computing the interference signal in post processing, it is possible to reduce the computational time required by the simulations and, thus, to simulate much bigger environments. Moreover, it is possible to simulate successive A lines and thus obtaining a cross section of the sample considered. In this paper we present the model applied to two different samples: a glass rod filled with water-sucrose solution at different concentrations and a peripheral nerve. This work demonstrates the feasibility of using OCT for non-invasive, direct optical monitoring of peripheral nerve activity, which is a long-sought goal of neuroscience.
129 - Si Chen , Kan Lin , Linbo Liu 2021
Optical coherence tomography angiography (OCTA) has been established as a powerful tool for investigating vascular diseases and is expected to become a standard of care technology. However, its widespread clinical usage is hindered by technical gaps such as limited field of view (FOV), lack of quantitative flow information, and suboptimal motion correction. Here we report a new imaging platform, termed spectrally extended line field (SELF) OCTA that provides advanced solutions to the above-mentioned challenges. SELF-OCTA breaks the speed limitations and achieves two-fold gain in FOV without sacrificing signal strength through parallel image acquisition. Towards quantitative angiography, the frequency flow imaging mechanism overcomes the imaging speed bottleneck by obviating the requirement for superfluous B-scans. In addition, the frequency flow imaging mechanism facilitates OCTA-data based motion tracking with overlap between adjacent line fields. Since it can be implemented in any existing OCT device without significant hardware modification or affecting existing functions, we expect that SELF-OCTA will make non-invasive, wide field, quantitative, and low-cost angiographic imaging available to larger patient populations.
The speckle statistics of optical coherence tomography images of biological tissue have been studied using several historical probability density functions. A recent hypothesis implies that underlying power-law distributions in the medium structure, such as the fractal branching vasculature, will contribute to power-law probability distributions of speckle statistics. Specifically, these are the Burr type XII distribution for speckle amplitude, the Lomax distribution for intensity, and the generalized logistic distribution for log amplitude. In this study, these three distributions are fitted to histogram data from nine optical coherence tomography scans of various biological tissues and samples. The distributions are also compared with conventional distributions such as the Rayleigh, K, and gamma distributions. The results indicate that these newer distributions based on power laws are, in general, more appropriate models and support the plausibility of their use for characterizing biological tissue. Potentially, the governing power-law parameter of these distributions could be used as a biomarker for tissue disease or pathology.
We present differential phase-contrast optical coherence tomography (DPC-OCT) with two transversally separated probing beams to sense phase gradients in various directions by employing a rotatable Wollaston prism. In combination with a two-dimensional mathe- matical reconstruction algorithm based on a regularized shape from shading (SfS) method accurate quantitative phase maps can be determined from a set of two orthogonal en-face DPC-OCT images, as exemplified on various technical samples.
Although cone-beam CT (CBCT) has been used to guide irradiation for pre-clinical radiotherapy(RT) research, it is limited to localize soft tissue target especially in a low imaging contrast environment. Knowledge of target shape is a fundamental need for RT. Without such information to guide radiation, normal tissue can be irradiated unnecessarily, leading to experimental uncertainties. Recognition of this need led us to develop quantitative bioluminescence tomography (QBLT), which provides strong imaging contrast to localize optical targets. We demonstrated its capability of guiding conformal RT using an orthotopic bioluminescent glioblastoma (GBM) model. With multi-projection and multi-spectral bioluminescence imaging and a novel spectral derivative method, our QBLT system is able to reconstruct GBM with localization accuracy <1mm. An optimal threshold was determined to delineate QBLT reconstructed gross target volume (GTV_{QBLT}), which provides the best overlap between the GTV_{QBLT} and CBCT contrast labeled GBM (GTV), used as the ground truth for the GBM volume. To account for the uncertainty of QBLT in target localization and volume delineation, we also innovated a margin design; a 0.5mm margin was determined and added to GTV_{QBLT} to form a planning target volume (PTV_{QBLT}), which largely improved tumor coverage from 75% (0mm margin) to 98% and the corresponding variation (n=10) of the tumor coverage was significantly reduced. Moreover, with prescribed dose 5Gy covering 95% of PTV_{QBLT}, QBLT-guided 7-field conformal RT can irradiate 99.4 pm 1.0% of GTV vs. 65.5 pm 18.5% with conventional single field irradiation (n=10). Our QBLT-guided system provides a unique opportunity for researchers to guide irradiation for soft tissue targets and increase rigorous and reproducibility of scientific discovery.