Do you want to publish a course? Click here

Dark zone maintenance results for segmented aperture wavefront error drift in a high contrast space coronagraph

210   0   0.0 ( 0 )
 Added by Susan Redmond
 Publication date 2021
  fields Physics
and research's language is English




Ask ChatGPT about the research

Due to the limited number of photons, directly imaging planets requires long integration times with a coronagraphic instrument. The wavefront must be stable on the same time scale, which is often difficult in space due to thermal variations and other mechanical instabilities. In this paper, we discuss the implications on future space mission observing conditions of our recent laboratory demonstration of a dark zone maintenance (DZM) algorithm. The experiments are performed on the High-contrast imager for Complex Aperture Telescopes (HiCAT) at the Space Telescope Science Institute (STScI). The testbed contains a segmented aperture, a pair of continuous deformable mirrors (DMs), and a lyot coronagraph. The segmented aperture injects high order wavefront aberration drifts into the system which are then corrected by the DMs downstream via the DZM algorithm. We investigate various drift modes including segmented aperture drift, all three DMs drift simultaneously, and drift correction at multiple wavelengths.



rate research

Read More

Segmented telescopes are a possibility to enable large-aperture space telescopes for the direct imaging and spectroscopy of habitable worlds. However, the complexity of their aperture geometry, due to the central obstruction, support structures and segment gaps, makes high-contrast imaging challenging. The High-contrast Imager for Complex Aperture Telescopes (HiCAT) testbed was designed to study and develop solutions for such telescope pupils using wavefront control and coronagraphic starlight suppression. The testbed design has the flexibility to enable studies with increasing complexity for telescope aperture geometries: off-axis telescopes, on-axis telescopes with central obstruction and support structures - e.g. the Wide Field Infrared Survey Telescope (WFIRST) - to on-axis segmented telescopes, including various concepts for a Large UV, Optical, IR telescope (LUVOIR). In the past year, HiCAT has made significant hardware and software updates to accelerate the development of the project. In addition to completely overhauling the software that runs the testbed, we have completed several hardware upgrades, including the second and third deformable mirror, and the first custom Apodized Pupil Lyot Coronagraph (APLC) optimized for the HiCAT aperture, which is similar to one of the possible geometries considered for LUVOIR. The testbed also includes several external metrology features for rapid replacement of parts, and in particular the ability to test multiple apodizers readily, an active tip-tilt control system to compensate for local vibration and air turbulence in the enclosure. On the software and operations side, the software infrastructure enables 24/7 automated experiments that include routine calibration tasks and high-contrast experiments. We present an overview and status update of the project, on the hardware and software side, and describe results obtained with APLC WFC.
Direct exoplanet imaging via coronagraphy requires maintenance of high contrast in a dark hole for lengthy integration periods. Wavefront errors that change slowly over that time accumulate and cause systematic errors in the stars Point Spread Function (PSF) which limit the achievable signal-to-noise ratio of the planet. In this paper we show that estimating the speckle drift can be achieved via intensity measurements in the dark hole together with dithering of the deformable mirrors to increase phase diversity. A scheme based on an Extended Kalman Filter and Electric Field Conjugation is proposed for maintaining the dark hole during the integration phase. For the post-processing phase, an a posteriori approach is proposed to estimate the realization of the PSF drift process and the intensity of the planet light incoherent with the speckles.
The characterization of exoplanet atmospheres using direct imaging spectroscopy requires high-contrast over a wide wavelength range. We study a recently proposed focal plane wavefront estimation algorithm that exclusively uses broadband images to estimate the electric field. This approach therefore reduces the complexity and observational overheads compared to traditional single wavelength approaches. The electric field is estimated as an incoherent sum of monochromatic intensities with the pair-wise probing technique. This paper covers the detailed implementation of the algorithm and an application to the High-contrast Imager for Complex Aperture Telescopes (HiCAT) testbed with the goal to compare the performance between the broadband and traditional narrowband filter approaches.
331 - Hanshin Lee 2014
The shape of a focus-modulated point spread function (PSF) is used as a quick visual assessment tool of aberration modes in the PSF. Further analysis in terms of shape moments can permit quantifying the modal coefficients with an accuracy comparable to that of typical wavefront sensors. In this letter, the error of the moment-based wavefront sensing is analytically described in terms of the pixelation and photon/readout noise. All components highly depend on the (unknown) PSF shape, but can be estimated from the measured PSF sampled at a reasonable spatial resolution and photon count. Numerical simulations verified that the models consistently predicted the behavior of the modal estimation error of the moment-based wavefront sensing.
HiCAT is a high-contrast imaging testbed designed to provide complete solutions in wavefront sensing, control and starlight suppression with complex aperture telescopes. The pupil geometry of such observatories includes primary mirror segmentation, central obstruction, and spider vanes, which make the direct imaging of habitable worlds very challenging. The testbed alignment was completed in the summer of 2014, exceeding specifications with a total wavefront error of 12nm rms over a 18mm pupil. The installation of two deformable mirrors for wavefront control is to be completed in the winter of 2015. In this communication, we report on the first testbed results using a classical Lyot coronagraph. We also present the coronagraph design for HiCAT geometry, based on our recent development of Apodized Pupil Lyot Coronagraph (APLC) with shaped-pupil type optimizations. These new APLC-type solutions using two-dimensional shaped-pupil apodizer render the system quasi-insensitive to jitter and low-order aberrations, while improving the performance in terms of inner working angle, bandpass and contrast over a classical APLC.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا