Do you want to publish a course? Click here

Virtual synchronous generator of PV generation without energy storage for frequency support in autonomous microgrid

156   0   0.0 ( 0 )
 Added by Yang Li
 Publication date 2021
and research's language is English




Ask ChatGPT about the research

In autonomous microgrids frequency regulation (FR) is a critical issue, especially with a high level of penetration of the photovoltaic (PV) generation. In this study, a novel virtual synchronous generator (VSG) control for PV generation was introduced to provide frequency support without energy storage. PV generation reserve a part of the active power in accordance with the pre-defined power versus voltage curve. Based on the similarities of the synchronous generator power-angle characteristic curve and the PV array characteristic curve, PV voltage Vpv can be analogized to the power angle {delta}. An emulated governor (droop control) and the swing equation control is designed and applied to the DC-DC converter. PV voltage deviation is subsequently generated and the pre-defined power versus voltage curve is modified to provide the primary frequency and inertia support. A simulation model of an autonomous microgrid with PV, storage, and diesel generator was built. The feasibility and effectiveness of the proposed VSG strategy are examined under different operating conditions.



rate research

Read More

With the increasing impact of low inertia due to the high penetration of distributed generation, virtual synchronous generator (VSG) technology has been proposed to improve the stability of the inverter-interfaced distributed generator by providing virtual inertia. This paper presents a recent review of virtual inertia control covering significance, features, design principles, and state-of-art inertia strategies from both physical and mathematical perspectives to facilitate the wide application of the VSG. The definition and source of virtual inertia are given to help researchers to establish the concept of virtual inertia. Then, this paper covers influencing mechanism studies of virtual inertia to reveal its functions. Also, a design framework of the virtual inertia is established by considering both the characteristics of the control system and the limitation of energy storage systems and renewable energy resources. Finally, several novel adaptive inertia control strategies are reviewed, and some aspects of potential future research are recommended.
The virtual synchronous generator technology analogs the characteristics of the synchronous generator via the controller design. It improved the stability of the grid systems which include the new energy. At the same time, according to the adjustable characteristics of the virtual synchronous generator parameters, the parameter adaptive adjustment is used to improve the dynamic performance of the system. However, the traditional virtual synchronous generator adaptive control technology still has two drawbacks: on the one hand, the large-scale adjustment of the damping droop coefficient and the virtual moment of inertia requires the system having a high energy storage margin; On the other hand, there is a power overshoot phenomenon in the transient regulation process, which is disadvantageous to the power equipment. First, this paper provides a convenient adjustment method for improving the transient stability of the system, the system damping is adjusted by introducing the output speed feedback. Second, according to the transient power-angle characteristics of the system, a parameter adaptive control strategy is proposed, which shortens the transient adjustment time and ensures that the deviation of the system frequency in the transient adjustment process is within the allowable range, and improves the transient performance of the grid frequency adjustment, at the same time, the power overshoot is suppressed. Finally, the experimental results show that the proposed control strategy is superior to the existing adaptive control strategy.
74 - Yue Shen , Maxim Bichuch , 2020
This work seeks to quantify the benefits of using energy storage toward the reduction of the energy generation cost of a power system. A two-fold optimization framework is provided where the first optimization problem seeks to find the optimal storage schedule that minimizes operational costs. Since the operational cost depends on the storage capacity, a second optimization problem is then formulated with the aim of finding the optimal storage capacity to be deployed. Although, in general, these problems are difficult to solve, we provide a lower bound on the cost savings for a parametrized family of demand profiles. The optimization framework is numerically illustrated using real-world demand data from ISO New England. Numerical results show that energy storage can reduce energy generation costs by at least 2.5 %.
In order to improve dynamic characteristics of the power system with high-proportion renewable energy sources (RESs), it is necessary for the voltage source converter (VSC), interfaces of RESs, to provide inertial and frequency regulation. In practical applications, VSCs are better to be controlled as a current source due to its weak overcurrent capacity. According to the characteristic, a dual synchronous theory is proposed to analyze the synchronization between current sources in this paper. Based on dual synchronous idea, a dual synchronous generator (DSG) control is applied in VSC to form inertial current source. In addition, a braking control is embedded in DSG control to improve the transient stability of VSC. Finally, experimental results verify the effectiveness of the theory and the control method.
The occurrence of voltage violations are a major deterrent for absorbing more roof-top solar power to smart Low Voltage Distribution Grids (LVDG). Recent studies have focused on decentralized control methods to solve this problem due to the high computational time in performing load flows in centralized control techniques. To address this issue a novel sensitivity matrix is developed to estimate voltages of the network by replacing load flow simulations. In this paper, a Centralized Active, Reactive Power Management System (CARPMS) is proposed to optimally utilize the reactive power capability of smart photo-voltaic inverters with minimal active power curtailment to mitigate the voltage violation problem. The developed sensitivity matrix is able to reduce the time consumed by 48% compared to load flow simulations, enabling near real-time control optimization. Given the large solution space of power systems, a novel two-stage optimization is proposed, where the solution space is narrowed down by a Feasible Region Search (FRS) step, followed by Particle Swarm Optimization (PSO). The performance of the proposed methodology is analyzed in comparison to the load flow method to demonstrate the accuracy and the capability of the optimization algorithm to mitigate voltage violations in near real-time. The deviation of mean voltages of the proposed methodology from load flow method was; 6.5*10^-3 p.u for reactive power control using Q-injection, 1.02*10^-2 p.u for reactive power control using Q-absorption, and 0 p.u for active power curtailment case.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا