Do you want to publish a course? Click here

On Stability Analysis of Power Grids with Synchronous Generators and Grid-Forming Converters under DC-side Current Limitation

153   0   0.0 ( 0 )
 Added by Sayan Samanta
 Publication date 2021
and research's language is English




Ask ChatGPT about the research

Stability of power grids with synchronous generators (SGs) and renewable generation interfaced with grid-forming converters (GFCs) under dc-side current limitation is studied. To that end, we first consider a simple 2-bus test system and reduced-order models to highlight the fundamental difference between two classes of GFC controls -- (A) droop, dispatchable virtual oscillator control (dVOC) and virtual synchronous machine (VSM), and (B) matching control. Next, we study Lyapunov stability and input-output stability of the dc voltage dynamics of class-A GFCs for the simple system and extend it to a generic system. Next, we provide a sufficiency condition for input-to-state stability of the 2-bus system with a class-B GFC and extend it for a generic system. Finally, time-domain simulations from a reduced-order averaged model of the simple test system and a detailed switched model of the GFC validate the proposed conditions.



rate research

Read More

147 - Yuan Gao , Hai-Peng Ren , Jie Li 2020
The renewable energy is connected to the power grid through power electronic converters, which are lack of make the inertia of synchronous generator/machine (SM) be lost. The increasing penetration of renewable energy in power system weakens the frequency and voltage stability. The Grid-Forming Converters (GFCs) simulate the function of synchronous motor through control method in order to improve the stability of power grid by providing inertia and stability regulation mechanism. This kind of converter control methods include virtual synchronous machine, schedulable virtual oscillator control and so on. These control method mainly use AC side state feedback and do not monitor the DC side state. This paper analyzes the control strategy of GFC considering power grid stability, including Frequency Droop Control, Virtual Synchronous Machine Control and dispatchable Virtual Oscillator Control. The DC side voltage collapse problem is found when a large load disturbance occurs. The control methods of GFC considering DC side voltage feedback are proposed, which can ensure the synchronization characteristics of grid connection and solve the problem of DC side voltage collapse. The proposed method is verified by IEEE-9 bus system, which shows the effectiveness of the proposed method.
204 - Huanhai Xin , Ziheng Li , Wei Dong 2017
The output impedance matrix of a grid-connected converter plays an important role in analyzing system stability. Due to the dynamics of the DC-link control and the phase locked loop (PLL), the output impedance matrices of the converter and grid are difficult to be diagonally decoupled simultaneously, neither in the dq domain nor in the phase domain. It weakens the effectiveness of impedance-based stability criterion (ISC) in system oscillation analysis. To this end, this paper innovatively proposes the generalized-impedance based stability criterion (GISC) to reduce the dimension of the transfer function matrix and simplify system small-signal stability analysis. Firstly, the impedances of the converter and the grid in polar coordinates are formulated, and the concept of generalized-impedance of the converter and the grid is put forward. Secondly, through strict mathematical derivation, the equation that implies the dynamic interaction between the converter and the grid is then extracted from the characteristic equation of the grid-connected converter system. Using the proposed method, the small-signal instability of system can be interpreted as the resonance of the generalized-impedances of the converter and the grid. Besides, the GISC is equivalent to ISC when the dynamics of the outer-loop control and PLL are not considered. Finally, the effectiveness of the proposed method is further verified using the MATLAB based digital simulation and RT-LAB based hardware-in-the-loop (HIL) simulation.
One of the fundamental concerns in the operation of modern power systems is the assessment of their frequency stability in case of inertia-reduction induced by the large share of power electronic interfaced resources. Within this context, the paper proposes a framework that, by making use of linear models of the frequency response of different types of power plants, including also grid--forming and grid-following converters, is capable to infer a numerically tractable dynamical model to be used in frequency stability assessment. Furthermore, the proposed framework makes use of models defined in a way such that their parameters can be inferred from real-time measurements feeding a classical least squares estimator. The paper validates the proposed framework using a full-replica of the dynamical model of the IEEE 39 bus system simulated in a real-time platform.
We apply a novel data-enabled predictive control (DeePC) algorithm in grid-connected power converters to perform safe and optimal control. Rather than a model, the DeePC algorithm solely needs input/output data measured from the unknown system to predict future trajectories. We show that the DeePC can eliminate undesired oscillations in a grid-connected power converter and stabilize an unstable system. However, the DeePC algorithm may suffer from poor scalability when applied in high-order systems. To this end, we present a finite-horizon output-based model predictive control (MPC) for grid-connected power converters, which uses an N-step auto-regressive-moving-average (ARMA) model for system representation. The ARMA model is identified via an N-step prediction error method (PEM) in a recursive way. We investigate the connection between the DeePC and the concatenated PEM-MPC method, and then analytically and numerically compare their closed-loop performance. Moreover, the PEM-MPC is applied in a voltage source converter based HVDC station which is connected to a two-area power system so as to eliminate low-frequency oscillations. All of our results are illustrated with high-fidelity, nonlinear, and noisy simulations.
With the advancement of the idea of the HVDC grid, it becomes imperative to study the interaction of controller and identification of modes of oscillations. The paper presents the complete model of HVDC grid with detailed modeling of controllers, phase lock loops (PLLs), dc grid and the ac systems. An analytical method combining participation factors and Eigen-sensitivity is proposed to determine the relative stability of the HVDC grid with respect to parameter variations. The paper also proposes the identification of inter-area and controller interaction modes on the basis of the nearest distance between the eigenvalues using the derived sensitivity indices. The critical parameters are varied in a mixed short circuit ratio (SCR) HVDC grid and predictions from the analysis method are confirmed with time-domain simulation in PSCAD simulator
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا