Do you want to publish a course? Click here

Coherent Magneto-Optomechanical Signal Transduction and Long-Distance Phase-Shift Keying

155   0   0.0 ( 0 )
 Added by John Davis
 Publication date 2019
  fields Physics
and research's language is English




Ask ChatGPT about the research

A transducer capable of converting quantum information stored as microwaves into telecom-wavelength signals is a critical piece of future quantum technology as it promises to enable the networking of quantum processors. Cavity optomechanical devices that are simultaneously coupled to microwave fields and optical resonances are being pursued in this regard. Yet even in the classical regime, developing optical modulators based on cavity optomechanics could provide lower power or higher bandwidth alternatives to current technology. Here we demonstrate a magnetically-mediated wavelength conversion technique, based on mixing high frequency tones with an optomechanical torsional resonator. This process can act either as an optical phase or amplitude modulator depending on the experimental configuration, and the carrier modulation is always coherent with the input tone. Such coherence allows classical information transduction and transmission via the technique of phase-shift keying. We demonstrate that we can encode up to eight bins of information, corresponding to three bits, simultaneously and demonstrate the transmission of an 52,500 pixel image over 6 km of optical fiber with just 0.67% error. Furthermore, we show that magneto-optomechanical transduction can be described in a fully quantum manner, implying that this is a viable approach to signal transduction at the single quantum level.



rate research

Read More

A series of short time stochastic resonance (SR) phenomena, realized in a bistable receiver, can be utilized to convey train of information represented by frequency-shift keying (FSK) signals. It is demonstrated that the SR regions of the input noise intensity are adjacent for input periodic signals that differ in frequency appropriately. This establishes the possibility of decomposing M-ary FSK signals in bistable receivers. Furthermore, the mechanism of the M-ary FSK signal detection via short time SR effects is explicated in terms of the receiver response speed. The short time SR phenomenon might be of interest for neuronal information processing in non-stationary noisy environments, regardless of the short timescale or the frequency jitter of stimulus.
We show that simple, commercially sourced n-channel silicon field-effect transistors (nFETs) operating under closed loop control exhibit an ~3-fold improvement in pH readout resolution to (7.2+/-0.3)x10^-3 at a bandwidth of 10 Hz when compared with the open loop operation commonly employed by integrated ion-sensitive field-effect transistors (ISFETs). We leveraged the improved nFET performance to measure the change in solution pH arising from the activity of a pathological form of the kinase Cdk5, an enzyme implicated in Alzheimers disease, and showed quantitative agreement with previous measurements. The improved pH resolution was realized while the devices were operated in a remote sensing configuration with the pH sensing element off-chip and connected electrically to the FET gate terminal. We compared these results with those measured by using a custom-built dual-gate 2D field-effect transistor (dg2DFET) fabricated with 2D semi-conducting MoS2 channels and a moderate device gain, alpha=8. Under identical solution conditions the pH resolution of the nFETs was only 2-fold worse than the dg2DFETs pH resolution of (3.9+/-0.7)x10^-3. Finally, using the nFETs, we demonstrated the effectiveness of a custom polypeptide, p5, as a therapeutic agent in restoring the function of Cdk5. We expect that the straight-forward modifications to commercially sourced nFETs demonstrated here will lower the barrier to widespread adoption of these remote-gate devices and enable sensitive bioanalytical measurements for high throughput screening in drug discovery and precision medicine applications.
Solid-state quantum acoustodynamic (QAD) systems provide a compact platform for quantum information storage and processing by coupling acoustic phonon sources with superconducting or spin qubits. The multi-mode composite high-overtone bulk acoustic wave resonator (HBAR) is a popular phonon source well suited for QAD. However, scattering from defects, grain boundaries, and interfacial/surface roughness in the composite transducer severely limits the phonon relaxation time in sputter-deposited devices. Here, we grow an epitaxial-HBAR, consisting of a metallic NbN bottom electrode and a piezoelectric GaN film on a SiC substrate. The acoustic impedance-matched epi-HBAR has a power injection efficiency > 99% from transducer to phonon cavity. The smooth interfaces and low defect density reduce phonon losses, yielding fxQ products and phonon lifetimes up to 1.36 x 10^17 Hz and 500 microseconds respectively. The GaN/NbN/SiC epi-HBAR is an electrically actuated, multi-mode phonon source that can be directly interfaced with NbN-based superconducting qubits or SiC-based spin qubits.
We report the isolation of thin flakes of cylindrite, a naturally occurring van der Waals superlattice, by means of mechanical and liquid phase exfoliation. We find that this material is a heavily doped p-type semiconductor with a narrow gap (<0.85 eV) with intrinsic magnetic interactions that are preserved even in the exfoliated nanosheets. Due to its environmental stability and high electrical conductivity, cylindrite can be an interesting alternative to the existing two-dimensional magnetic materials.
We report the study of a tri-axial vector magnetoresistance (MR) in nonmagnetic (Bi1-xInx)2Se3 nanodevices at the composition of x = 0.08. We show a dumbbell-shaped in-plane negative MR up to room temperature as well as a large out-of-plane positive MR. MR at three directions is about in a -3%: -1%: 225% ratio at 2 K. Through both the thickness and composition-dependent magnetotransport measurements, we show that the in-plane negative MR is due to the topological phase transition enhanced intersurface coupling near the topological critical point. Our devices suggest the great potential for room-temperature spintronic applications, for example, vector magnetic sensors.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا