No Arabic abstract
In this work we describe an experimental setup for spatially-resolved pump-probe experiment with integrated wide-field magneto-optical (MO) microscope. The MO microscope can be used to study ferromagnetic materials with both perpendicular-to-plane and in-plane magnetic anisotropy via polar Kerr and Voigt effects, respectively. The functionality of the Voigt effect-based microscope was tested using an in-plane magnetized ferromagnetic semiconductor (Ga,Mn)As. It was revealed that the presence of mechanical defects in the (Ga,Mn)As epilayer alters significantly the magnetic anisotropy in their proximity. The importance of MO experiments with simultaneous temporal and spatial resolutions was demonstrated using (Ga,Mn)As sample attached to a piezoelectric actuator, which produces a voltage-controlled strain. We observed a considerably different behavior in different parts of the sample that enabled us to identify sample parts where the epilayer magnetic anisotropy was significantly modified by a presence of the piezostressor and where it was not. Finally, we discuss the possible applicability of our experimental setup for the research of compensated antiferromagnets, where only MO effects even in magnetic moments are present.
Recent demonstrations of electrical detection and manipulation of antiferromagnets (AFMs) have opened new opportunities towards robust and ultrafast spintronics devices. However, it is difficult to establish the connection between the spin-transport behavior and the microscopic AFM domain states due to the lack of the real-time AFM domain imaging technique under the electric field. Here we report a significant Voigt rotation up to 60 mdeg in thin NiO(001) films at room temperature. Such large Voigt rotation allows us to directly observe AFM domains in thin-film NiO by utilizing a wide-field optical microscope. Further complementary XMLD-PEEM measurement confirms that the Voigt contrast originates from the NiO AFM order. We examine the domain pattern evolution at a wide range of temperature and with the application of external magnetic field. Comparing to large-scale-facility techniques such as the X-ray photoemission electron microscopy, the use with a wide-field, tabletop optical imaging method enables straightforward access to domain configurations of single-layer AFMs.
We report on a quantitative experimental determination of the three-dimensional magnetization vector trajectory in GaMnAs by means of the static and time-resolved pump-and-probe magneto-optical measurements. The experiments are performed in a normal incidence geometry and the time evolution of the magnetization vector is obtained without any numerical modeling of magnetization dynamics. Our experimental method utilizes different polarization dependences of the polar Kerr effect and magnetic linear dichroism to disentangle the pump-induced out-of-plane and in-plane motions of magnetization, respectively. We demonstrate that the method is sensitive enough to allow for the determination of small angle excitations of the magnetization in GaMnAs. The method is readily applicable to other magnetic materials with sufficiently strong circular and linear magneto-optical effects.
Experimental advances allow for the inclusion of multiple probes to measure the transport properties of a sample surface. We develop a theory of dual-probe scanning tunnelling microscopy using a Greens Function formalism, and apply it to graphene. Sampling the local conduction properties at finite length scales yields real space conductance maps which show anisotropy for pristine graphene systems and quantum interference effects in the presence of isolated impurities. The spectral signatures of the Fourier transform of real space conductance maps include characteristics that can be related to different scattering processes. We compute the conductance maps of graphene systems with different edge geometries or height fluctuations to determine the effects of non-ideal graphene samples on dual-probe measurements.
A two-core transducer assembly using a Fe73.5Nb3Cu1Si13.5B9 ribbon to detect a change of magnetic field is proposed and tested for displacement (linear and angular) and current sensor. Two identical inductors, with the ribbon as core, are a part of two series resonance network, and are in high impedance state when excited by a small a.c field of 1MHz in absence of d.c biasing field (Hdc). When the magnetic state of one inductor is altered by biasing field, produced by a bar magnet or current carrying coil, an ac signal proportional to Hdc is generated by transducer. The results for the sensitivity and linearity with displacement (linear and angular) of a magnet and with field from the current carrying coil are presented for two particular configurations of the transducer. High sensitivities of voltage response as much as 12micro-volt/micro-meter and 3mV/degree have been obtained for the transducer as a linear and angular displacement sensor respectively in the transverse configuration of exciting a.c and biasing d.c fields.
The magneto-optic Voigt effect is observed in a synthetic diamond membrane with a substitutional nitrogen defect concentration in the order of 200 ppm and a nitrogen-vacancy defect sub-ensemble generated through neutron irradiation and annealing. The measured polarisation rotation in the reflected light is observed to be quadratically proportional to the applied magnetic field and to the incident reflection angle. Additionally, it is observed to be modifiable by illuminating the diamond with a 532 nm laser. Spectral analysis of the reflected light under 532 nm illumination shows a slow narrowing of the spectral distribution, indicating a small increase in the overall magnetisation, as opposed to magnetisation degradation caused by heating. Further analysis of the optical power dependence suggest this may be related to a shift in the spin ensembles charge state equilibrium and, by extension, the resulting ensemble magnetisation.