Accurate spectroscopy of highly charged high-Z ions in a storage ring is demonstrated to be feasible by the use of specially adapted crystal optics. The method has been applied for the measurement of the 1s Lamb shift in hydrogen-like gold (Au 78+) in a storage ring through spectroscopy of the Lyman x rays. This measurement represents the first result obtained for a high-Z element using high-resolution wavelength-dispersive spectroscopy in the hard x-ray regime, paving the way for sensitivity to higher-order QED effects.
Quantum electrodynamics in very strong Coulomb fields is one scope which has not yet been tested experimentally with suffcient accuracy to really determine whether the perturbative approach is valid. One sensitive test is the determination of the 1s Lamb Shift in highly-charged very heavy ions. The 1s Lamb Shift of hydrogen-like lead (Pb81+) and gold (Au78+) has been determined using the novel detector concept of silicon microcalorimeters for the detection of hard X-rays. The results of (260 +- 22) eV for lead and (208 +- 13) eV for gold are within error bars in good agreement with theoretical predictions. For hydrogen-like lead, this represents the most accurate determination of the 1s Lamb Shift to our knowledge.
We study the feasibility of nearly-degenerate two-photon rovibrational spectroscopy in ensembles of trapped, sympathetically cooled hydrogen molecular ions using a resonance-enhanced multiphoton dissociation (REMPD) scheme. Taking advantage of quasi-coincidences in the rovibrational spectrum, the excitation lasers are tuned close to an intermediate level to resonantly enhance two-photon absorption. Realistic simulations of the REMPD signal are obtained using a four-level model that takes into account saturation effects, ion trajectories, laser frequency noise and redistribution of population by blackbody radiation. We show that the use of counterpropagating laser beams enables optical excitation in an effective Lamb-Dicke regime. Sub-Doppler lines having widths in the 100 Hz range can be observed with good signal-to-noise ratio for an optimal choice of laser detunings. Our results indicate the feasibility of molecular spectroscopy at the $10^{-14}$ accuracy level for improved tests of molecular QED, a new determination of the proton-to-electron mass ratio, and studies of the time (in)dependence of the latter.
We report a new measurement of the $n=2$ Lamb shift in Muonium using microwave spectroscopy. Our result of $1047.2(2.3)_textrm{stat}(1.1)_textrm{syst}$ MHz comprises an order of magnitude improvement upon the previous best measurement. This value matches the theoretical calculation within one standard deviation allowing us to set limits on CPT violation in the muonic sector, as well as on new physics coupled to muons and electrons which could provide an explanation of the muon $g-2$ anomaly.
The measurement of the 2P^{F=2}_{3/2} to 2S^{F=1}_{1/2} transition in muonic hydrogen by Pohl et al. and subsequent analysis has led to the conclusion that the rms radius of the proton differs from the accepted (CODATA) value by approximately 4%, corresponding to a 4.9 sigma discrepancy. We investigate the finite-size effects - in particular the dependence on the shape of the proton electric form-factor - relevant to this transition using bound-state QED with nonperturbative, relativistic Dirac wave-functions for a wide range of idealised charge-distributions and a parameterization of experimental data in order to comment on the extent to which the perturbation-theory analysis which leads to the above conclusion can be confirmed. We find no statistically significant dependence of this correction on the shape of the proton form-factor.
The methods to measure the polarization of the x-rays from highly charged heavy ions with a significantly higher accuracy than the existing technology is needed to explore relativistic and quantum electrodynamics (QED) effects including the Breit interaction. We developed the Electron Beam Ion Trap Compton Camera (EBIT-CC), a new Compton polarimeter with pixelated multi-layer silicon and cadmium telluride counters. The EBIT-CC detects the three-dimensional position of Compton scattering and photoelectric absorption, and thus the degree of polarization of incoming x-rays can be evaluated. We attached the EBIT-CC on the Tokyo Electron Beam Ion Trap (Tokyo-EBIT) in the University of Electro-Communications. An experiment was performed to evaluate its polarimetric capability through an observation of radiative recombination x-rays emitted from highly charged krypton ions, which were generated by the Tokyo-EBIT. The Compton camera of the EBIT-CC was calibrated for the 75 keV x-rays. We developed event reconstruction and selection procedures and applied them to every registered event. As a result, we successfully obtained the polarization degree with an absolute uncertainty of 0.02. This uncertainty is small enough to probe the difference between the zero-frequency approximation and full-frequency-dependent calculation for the Breit interaction, which is expected for dielectronic recombination x-rays of highly charged heavy ions.
T. Gassner
,M. Trassinelli
,R. He{ss}
.
(2017)
.
"Wavelength-dispersive spectroscopy in the hard x-ray regime of a heavy highly-charged ion: The 1s Lamb shift in hydrogen-like gold"
.
Martino Trassinelli