Do you want to publish a course? Click here

Mapping the aberrations of a wide-field spectrograph using a photonic comb

56   0   0.0 ( 0 )
 Added by Joss Bland-Hawthorn
 Publication date 2017
  fields Physics
and research's language is English




Ask ChatGPT about the research

We demonstrate a new approach to calibrating the spectral-spatial response of a wide-field spectrograph using a fibre etalon comb. Conventional wide-field instruments employed on front-line telescopes are mapped with a grid of diffraction-limited holes cut into a focal plane mask. The aberrated grid pattern in the image plane typically reveals n-symmetric (e.g. pincushion) distortion patterns over the field arising from the optical train. This approach is impractical in the presence of a dispersing element because the diffraction-limited spots in the focal plane are imaged as an array of overlapping spectra. Instead we propose a compact solution that builds on recent developments in fibre-based Fabry-Perot etalons. We introduce a novel approach to near-field illumination that exploits a 25cm commercial telescope and the propagation of skew rays in a multimode fibre. The mapping of the optical transfer function across the full field is represented accurately (<0.5% rms residual) by an orthonormal set of Chebyshev moments. Thus we are able to reconstruct the full 4Kx4K CCD image of the dispersed output from the optical fibres using this mapping, as we demonstrate. Our method removes one of the largest sources of systematic error in multi-object spectroscopy.



rate research

Read More

Binospec is a high throughput, 370 to 1000 nm, imaging spectrograph that addresses two adjacent 8 by 15 fields of view. Binospec was commissioned in late 2017 at the f/5 focus of the 6.5m MMT and is now available to all MMT observers. Aperture masks cut from stainless steel with a laser cutter are used to define the entrance apertures that range from 15 long slits to hundreds of 2 slitlets. System throughputs, including the MMTs mirrors and the f/5 wide-field corrector peak at ~30%. Three reflection gratings, duplicated for the two beams, provide resolutions ($lambda$/$Delta lambda$) between 1300 and $>$5000 with a 1 wide slit. Two through-the-mask guiders are used for target acquisition, mask alignment, guiding, and precision offsets. A full-time Shack-Hartmann wave front sensor allows continuous adjustment of primary mirror support forces, telescope collimation and focus. Active flexure control maintains spectrograph alignment and focus under varying gravity and thermal conditions.
Using a turn-key Ti:sapphire femtosecond laser frequency comb, an off-the-shelf supercontinuum device, and Fabry-Perot mode filters, we report the generation of a 16 GHz frequency comb spanning a 90 nm band about a center wavelength of 566 nm. The light from this astro-comb is used to calibrate the HARPS-N astrophysical spectrograph for precision radial velocity measurements. The comb-calibrated spectrograph achieves a stability of $sim$ 1 cm/s within half an hour of averaging time. We also use the astro-comb as a reference for measurements of solar spectra obtained with a compact telescope, and as a tool to study intrapixel sensitivity variations on the CCD of the spectrograph.
This paper describes the on-telescope performance of the Wide Field Spectrograph (WiFeS). The design characteristics of this instrument, at the Research School of Astronomy and Astrophysics (RSAA) of the Australian National University (ANU) and mounted on the ANU 2.3m telescope at the Siding Spring Observatory has been already described in an earlier paper (Dopita et al. 2007). Here we describe the throughput, resolution and stability of the instrument, and describe some minor issues which have been encountered. We also give a description of the data reduction pipeline, and show some preliminary results.
189 - Marc Balcells 2010
Wide-field multi-object spectroscopy is a high priority for European astronomy over the next decade. Most 8-10m telescopes have a small field of view, making 4-m class telescopes a particularly attractive option for wide-field instruments. We present a science case and design drivers for a wide-field multi-object spectrograph (MOS) with integral field units for the 4.2-m William Herschel Telescope (WHT) on La Palma. The instrument intends to take advantage of a future prime-focus corrector and atmospheric-dispersion corrector that will deliver a field of view 2 deg in diameter, with good throughput from 370 to 1,000 nm. The science programs cluster into three groups needing three different resolving powers R: (1) high-precision radial-velocities for Gaia-related Milky Way dynamics, cosmological redshift surveys, and galaxy evolution studies (R = 5,000), (2) galaxy disk velocity dispersions (R = 10,000) and (3) high-precision stellar element abundances for Milky Way archaeology (R = 20,000). The multiplex requirements of the different science cases range from a few hundred to a few thousand, and a range of fibre-positioner technologies are considered. Several options for the spectrograph are discussed, building in part on published design studies for E-ELT spectrographs. Indeed, a WHT MOS will not only efficiently deliver data for exploitation of important imaging surveys planned for the coming decade, but will also serve as a test-bed to optimize the design of MOS instruments for the future E-ELT.
SOXS (Son Of X-Shooter) will be a spectrograph for the ESO NTT telescope capable to cover the optical and NIR bands, based on the heritage of the X-Shooter at the ESO-VLT. SOXS will be built and run by an international consortium, carrying out rapid and longer term Target of Opportunity requests on a variety of astronomical objects. SOXS will observe all kind of transient and variable sources from different surveys. These will be a mixture of fast alerts (e.g. gamma-ray bursts, gravitational waves, neutrino events), mid-term alerts (e.g. supernovae, X-ray transients), fixed time events (e.g. close-by passage of minor bodies). While the focus is on transients and variables, still there is a wide range of other astrophysical targets and science topics that will benefit from SOXS. The design foresees a spectrograph with a Resolution-Slit product ~ 4500, capable of simultaneously observing over the entire band the complete spectral range from the U- to the H-band. The limiting magnitude of R~20 (1 hr at S/N~10) is suited to study transients identified from on-going imaging surveys. Light imaging capabilities in the optical band (grizy) are also envisaged to allow for multi-band photometry of the faintest transients. This paper outlines the status of the project, now in Final Design Phase.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا