Do you want to publish a course? Click here

Astro-comb calibrator and spectrograph characterization using a turn-key laser frequency comb

68   0   0.0 ( 0 )
 Added by Aakash Ravi
 Publication date 2017
  fields Physics
and research's language is English




Ask ChatGPT about the research

Using a turn-key Ti:sapphire femtosecond laser frequency comb, an off-the-shelf supercontinuum device, and Fabry-Perot mode filters, we report the generation of a 16 GHz frequency comb spanning a 90 nm band about a center wavelength of 566 nm. The light from this astro-comb is used to calibrate the HARPS-N astrophysical spectrograph for precision radial velocity measurements. The comb-calibrated spectrograph achieves a stability of $sim$ 1 cm/s within half an hour of averaging time. We also use the astro-comb as a reference for measurements of solar spectra obtained with a compact telescope, and as a tool to study intrapixel sensitivity variations on the CCD of the spectrograph.



rate research

Read More

A compact green astro-comb with 43-GHz repetition rate is developed based on a Ti:Sapphire optical frequency comb (OFC) and a mode-selecting cavity. The OFCs large repetition rate of 1.6 GHz eases the requirements for the mode-selecting cavity. Unnecessary frequency-modes of the OFC are suppressed down to $5 times 10^{-4}$ at 535 nm - 550 nm using a single mode-selecting cavity with 70-MHz linewidth. The radial velocity precision $sigma sim 1.4$ m/s is achieved at the High Dispersion Echelle Spectrosraph for the Okayama 188-cm telescope of the National Astronomical Observatory of Japan using our astro-comb. With further improvements of the mode-selecting cavity and removal of fiber modal noises, our system will provide a simple, compact, and precise astro-comb setup in visible wavelength region.
117 - Hanzhong Wu , Jun Ke , Panpan Wang 2021
In this work, we describe an updated version of single arm locking, and the noise amplification due to the nulls can be flexibly restricted with the help of optical frequency comb. We show that, the laser phase noise can be divided by a specific factor with optical frequency comb as the bridge. The analytical results indicate that, the peaks in the science band have been greatly reduced. The performance of the noise suppression shows that the total noise after arm locking can well satisfy the requirement of time delay interferometry, even with the free-running laser source. We also estimate the frequency pulling characteristics of the updated single arm locking, and the results suggest that the pulling rate can be tolerated, without the risk of mode hopping. Arm locking will be a valuable solution for the noise reduction in the space-borne GW detectors. We demonstrate that, with the precise control of the returned laser phase noise, the noise amplification in the science band can be efficiently suppressed based on the updated single arm locking. Not only our method allows the suppression of the peaks, the high gain, low pulling rate, it can also serve for full year, without the potential risk of locking failure due to the arm length mismatch. We finally discuss the unified demonstration of the updated single arm locking, where both the local and the returned laser phase noises can be tuned to generate the expected arm-locking sensor actually. Our work could provide a powerful method for the arm locking in the future space-borne GW detectors.
We demonstrate an approach for automated Kerr comb generation in the normal group-velocity dispersion (GVD) regime. Using a coupled-ring geometry in silicon nitride, we precisely control the wavelength location and splitting strength of avoided mode crossings to generate low-noise frequency combs with pump-to-comb conversion efficiencies of up to 41%, which is the highest reported to date for normal-GVD Kerr combs. Our technique enables on-demand generation of a high-power comb source for applications such as wavelength-division multiplexing in optical communications.
134 - Bruno Chanteau 2012
We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line. The set-up uses an optical frequency comb and an ultrastable 1.55 $mu$m frequency reference signal, transferred from LNE-SYRTE to LPL through an optical link. We are now progressing towards the stabilization of the mid-IR laser via the frequency comb and the extension of this technique to quantum cascade lasers. Such a development is very challenging for ultrahigh resolution molecular spectroscopy and fundamental tests of physics with molecules.
183 - Michael T. Murphy 2012
Precise astronomical spectroscopic analyses routinely assume that individual pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons. Intra-pixel sensitivity (IPS) variations may already cause small systematic errors in, for example, studies of extra-solar planets via stellar radial velocities and cosmological variability in fundamental constants via quasar spectroscopy, but future experiments requiring velocity precisions approaching ~1 cm/s will be more strongly affected. Laser frequency combs have been shown to provide highly precise wavelength calibration for astronomical spectrographs, but here we show that they can also be used to measure IPS variations in astronomical CCDs in situ. We successfully tested a laser frequency comb system on the Ultra-High Resolution Facility spectrograph at the Anglo-Australian Telescope. By modelling the 2-dimensional comb signal recorded in a single CCD exposure, we find that the average IPS deviates by <8 per cent if it is assumed to vary symmetrically about the pixel centre. We also demonstrate that series of comb exposures with absolutely known offsets between them can yield tighter constraints on symmetric IPS variations from ~100 pixels. We discuss measurement of asymmetric IPS variations and absolute wavelength calibration of astronomical spectrographs and CCDs using frequency combs.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا