Do you want to publish a course? Click here

Efficient, high-resolution resonance laser ionization spectroscopy using weak transitions to long-lived excited states

55   0   0.0 ( 0 )
 Added by Ruben De Groote
 Publication date 2017
  fields Physics
and research's language is English




Ask ChatGPT about the research

Laser spectroscopic studies on minute samples of exotic radioactive nuclei require very efficient experimental techniques. In addition, high resolving powers are required to allow extraction of nu- clear structure information. Here we demonstrate that by using weak atomic transitions, resonance laser ionization spectroscopy is achieved with the required high efficiency (1-10%) and precision (linewidths of tens of MHz). We illustrate experimentally and through the use of simulations how the narrow experimental linewidths are achieved and how distorted resonance ionization spec- troscopy lineshapes can be avoided. The role of the delay of the ionization laser pulse with respect to the excitation laser pulse is crucial: the use of a delayed ionization step permits the best resolving powers and lineshapes. A high efficiency is maintained if the intermediate level has a lifetime that is at least of the order of the excitation laser pulse width. A model that describes this process re- produces well the observed features and will help to optimize the conditions for future experiments.



rate research

Read More

Long-lived isotopes of plutonium were studied using two complementary techniques, high-resolution resonance ionisation spectroscopy (HR-RIS) and collinear laser spectroscopy (CLS). Isotope shifts have been measured on the $5f^67s^2 ^7F_0 rightarrow 5f^56d^27s (J=1)$ and $5f^67s^2 ^7F_1 rightarrow 5f^67s7p (J=2)$ atomic transitions using the HR-RIS method and the hyperfine factors have been extracted for the odd mass nuclei $^{239,241}$Pu. Collinear laser spectroscopy was performed on the $5f^67s ^8F_{1/2} rightarrow J=1/2; (27523.61text{cm}^{-1})$ ionic transition with the hyperfine $A$ factors measured for $^{239}$Pu. Changes in mean-squared charge radii have been extracted and show a good agreement with previous non-optical methods, with an uncertainty improvement by approximately one order of magnitude. Plutonium represents the heaviest element studied to date using collinear laser spectroscopy.
As an important step towards an atomic parity violation experiment in one single trapped Ra$^+$ ion, laser spectroscopy experiments were performed with on-line produced short-lived $^{212,213,214}$Ra$^+$ ions. The isotope shift of the $6,^2$D$_{3/2}$,-,$7,^2$P$_{1/2}$ and $6,^2$D$_{3/2}$,-,$7,^2$P$_{3/2}$ transitions and the hyperfine structure constant of the $7,^2$S$_{1/2}$ and $6,^2$D$_{3/2}$ states in $^{213}$Ra$^+$ were measured. These values provide a benchmark for the required atomic theory. A lower limit of $232(4)$ ms for the lifetime of the metastable $6,^2$D$_{5/2}$ state was measured by optical shelving.
Silicon Drift Detectors, widely employed in high-resolution and high-rate X-ray applications, are considered here with interest also for electron detection. The accurate measurement of the tritium beta decay is the core of the TRISTAN (TRitium Investigation on STerile to Active Neutrino mixing) project. This work presents the characterization of a single-pixel SDD detector with a mono-energetic electron beam obtained from a Scanning Electron Microscope. The suitability of the SDD to detect electrons, in the energy range spanning from few keV to tens of keV, is demonstrated. Experimental measurements reveal a strong effect of the detectors entrance window structure on the observed energy response. A detailed detector model is therefore necessary to reconstruct the spectrum of an unknown beta-decay source.
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resolutions of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction and provide new accurate charged-kaon mass value.
Finding tracks downstream of the magnet at the earliest LHCb trigger level is not part of the baseline plan of the upgrade trigger, on account of the significant CPU time required to execute the search. Many long-lived particles, such as $K^0_S$ and strange baryons, decay after the vertex track detector, so that their reconstruction efficiency is limited. We present a study of the performance of a future innovative real-time tracking system based on FPGAs, developed within a R&D effort in the context of the LHCb Upgrade Ib (LHC Run~4), dedicated to the reconstruction of the particles downstream of the magnet in the forward tracking detector (Scintillating Fibre Tracker), that is capable of processing events at the full LHC collision rate of 30 MHz.