No Arabic abstract
A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below background level within a week after the source is closed. We find no increase in the activity of the troublesome Rn-222 background after calibration. Alpha emitters are also distributed throughout the detector and facilitate calibration of its response to Rn-222. Using the delayed coincidence of Rn-220/Po-216, we map for the first time the convective motion of particles in the XENON100 detector. Additionally, we make a competitive measurement of the half-life of Po-212, t = 293.9+-(1.0)+-(0.6) ns.
We characterize two 40 kBq sources of electrodeposited Th-228 for use in low-background experiments. The sources efficiently emanate Rn-220, a noble gas that can diffuse in a detector volume. Rn-220 and its daughter isotopes produce alpha, beta, and gamma-radiation, which may used to calibrate a variety of detector responses and features, before decaying completely in only a few days. We perform various tests to place limits on the release of other long-lived isotopes. In particular, we find an emanation of <0.008 atoms/min/kBq (90% CL) for Th-228 and 1.53 atoms/min/kBq for Ra-224. The sources lend themselves in particular to the calibration of detectors employing liquid noble elements such as argon and xenon. With the source mounted in a noble gas system, we demonstrate that filters are highly efficient in reducing the activity of these longer-lived isotopes further. We thus confirm the suitability of these sources even for use in next-generation experiments, such as XENON1T/XENONnT, LZ, and nEXO.
We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $alpha$, $beta$, and $gamma$ particles with focus on low energy ER events. During the runs in 2017 and 2018, the amount of radioactivity of $^{222}$Rn were on the order of 1% of that of $^{220}$Rn and thorium particulate contamination was negligible, especially in 2018. We also measured the background contribution from $^{214}$Pb for the first time in PandaX-II with the help from a $^{222}$Rn injection. Calibration strategy with $^{220}$Rn and $^{222}$Rn will be implemented in the upcoming PandaX-4T experiment and can be useful for other xenon-based detectors as well.
This article describes the design, construction and use of a calibration and monitoring system, based on movable 137Cs gamma-ray sources, for the ATLAS Tile Calorimeter (TileCal). The sources, propelled by a water-based liquid through tubes that traverse all the calorimeters cells, produce signals that precisely characterise the response of each tile, thereby providing very granular and accurate data on the response of TileCal to particles. The system has been used to guide and control the quality of the optical instrumentation of all TileCal modules, to set and equalise the dynamic range of the response to physics data, and to set the energy scale of the readout system. In the ATLAS cavern, periodic measurements of the whole detectors response to 137Cs sources allow monitoring the uniformity and stability of all the calorimeters cells as well as maintaining precise knowledge of its energy calibration. The design of the source hydraulic drive systems hardware and software, the data acquisition system and the data processing algorithms are described. Finally, the results of this two-decade program are shown.
We report on the construction and performance of a calibration source for KamLAND using the reaction C-13(alpha,n)O-16 with Po-210 as the alpha progenitor. The source provides a direct measurement of this background reaction in our detector, high energy calibration points for the detector energy scale, and data on quenching of the neutron visible energy in KamLAND scintillator. We also discuss the possibility of using the reaction C-13(alpha,n)O-16 as a source of tagged slow neutrons.
We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultra-low electromagnetic background of the experiment, ~$5 times 10^{-3}$ events/(keV$_{mathrm{ee}}times$kg$times$day) before electronic recoil rejection, together with the increased exposure of 48 kg $times$ yr improves the sensitivity. A profile likelihood analysis using an energy range of (6.6 - 43.3) keV$_{mathrm{nr}}$ sets a limit on the elastic, spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/$c^2$, with a minimum of 1.1 $times 10^{-45}$ cm$^2$ at 50 GeV/$c^2$ and 90% confidence level. We also report updated constraints on the elastic, spin-dependent WIMP-nucleon cross sections obtained with the same data. We set upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0 $times 10^{-40}$ cm$^2$ (52$times 10^{-40}$ cm$^2$) at a WIMP mass of 50 GeV/$c^2$, at 90% confidence level.