We report on the first measurement of the $beta^+$- and orbital electron capture decay rates of $^{140}$Pr nuclei with the most simple electron configurations: bare nuclei, hydrogen-like and helium-like ions. The measured electron capture decay constant of hydrogen-like $^{140}$Pr$^{58+}$ ions is about 50% larger than that of helium-like $^{140}$Pr$^{57+}$ ions. Moreover, $^{140}$Pr ions with one bound electron decay faster than neutral $^{140}$Pr$^{0+}$ atoms with 59 electrons. To explain this peculiar observation one has to take into account the conservation of the total angular momentum, since only particular spin orientations of the nucleus and of the captured electron can contribute to the allowed decay.
We report on time-modulated two-body weak decays observed in the orbital electron capture of hydrogen-like $^{140}$Pr$^{59+}$ and $^{142}$Pm$^{60+}$ ions coasting in an ion storage ring. Using non-destructive single ion, time-resolved Schottky mass spectrometry we found that the expected exponential decay is modulated in time with a modulation period of about 7 seconds for both systems. Tentatively this observation is attributed to the coherent superposition of finite mass eigenstates of the electron neutrinos from the weak decay into a two-body final state.
The periodic time modulations, found recently in the two-body orbital electron-capture (EC) decay of both, hydrogen-like $^{140}$Pr$^{58+}$ and $^{142}$Pm$^{60+}$ ions, with periods near to 7s and amplitudes of about 20%, were re-investigated for the case of $^{142}$Pm$^{60+}$ by using a 245 MHz resonator cavity with a much improved sensitivity and time resolution. We observed that the exponential EC decay is modulated with a period $T = 7.11(11)$s, in accordance with a modulation period $T = 7.12(11)$ s as obtained from simultaneous observations with a capacitive pick-up, employed also in the previous experiments. The modulation amplitudes amount to $a_R = 0.107(24)$ and $a_P = 0.134(27)$ for the 245 MHz resonator and the capacitive pick-up, respectively. These new results corroborate for both detectors {it exactly} our previous findings of modulation periods near to 7s, though with {it distinctly smaller} amplitudes. Also the three-body $beta^+$ decays have been analyzed. For a supposed modulation period near to 7s we found an amplitude $a = 0.027(27)$, compatible with $a = 0$ and in agreement with the preliminary result $a = 0.030(30)$ of our previous experiment. These observations could point at weak interaction as origin of the observed 7s-modulation of the EC decay. Furthermore, the data suggest that interference terms occur in the two-body EC decay, although the neutrinos are not directly observed.
An experiment addressing electron capture (EC) decay of hydrogen-like $^{142}$Pm$^{60+}$ ions has been conducted at the experimental storage ring (ESR) at GSI. The decay appears to be purely exponential and no modulations were observed. Decay times for about 9000 individual EC decays have been measured by applying the single-ion decay spectroscopy method. Both visually and automatically analysed data can be described by a single exponential decay with decay constants of 0.0126(7) s$^{-1}$ for automatic analysis and 0.0141(7) s$^{-1}$ for manual analysis. If a modulation superimposed on the exponential decay curve is assumed, the best fit gives a modulation amplitude of merely 0.019(15), which is compatible with zero and by 4.9 standard deviations smaller than in the original observation which had an amplitude of 0.23(4).
Two--photon decay of hydrogen--like ions is studied within the framework of second--order perturbation theory, based on relativistic Diracs equation. Special attention is paid to the effects arising from the summation over the negative--energy (intermediate virtual) states that occurs in such a framework. In order to investigate the role of these states, detailed calculations have been carried out for the $2s_{1/2} - 1s_{1/2}$ and $2p_{1/2} - 1s_{1/2}$ transitions in neutral hydrogen H as well as for hydrogen--like xenon Xe$^{53+}$ and uranium U$^{91+}$ ions. We found that for a correct evaluation of the total and energy--differential decay rates, summation over the negative--energy part of Diracs spectrum should be properly taken into account both for high--$Z$ and low--$Z$ atomic systems.
The eigenstate energies of an atom increase under spatial confinement and this effect should also increase the electron density of the orbital electrons at the nucleus thus increasing the decay rate of an electron-capturing radioactive nucleus. We have observed that the orbital electron capture rates of 109In and 110Sn increased by (1.00+-0.17)% and (0.48+-0.25)% respectively when implanted in the small Au lattice versus large Pb lattice. These results have been understood because of the higher compression experienced by the large radioactive atoms due to the spatial confinement in the smaller Au lattice.
Yu.A. Litvinov
,F. Bosch
,H. Geissel
.
(2007)
.
"Measurement of the $beta^+$ and orbital electron-capture decay rates in fully-ionized, hydrogen-like, and helium-like $^{140}$Pr ions"
.
Yuri Litvinov