ترغب بنشر مسار تعليمي؟ اضغط هنا

SND electromagnetic calorimeter time measurement and its applications

70   0   0.0 ( 0 )
 نشر من قبل Natalya Melnikova
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The SND is a non-magnetic detector deployed at the VEPP-2000 $e^+e^-$ collider (BINP, Novosibirsk) for hadronic cross-section measurements in the center of mass energy region below 2 GeV. The important part of the detector is a three-layer hodoscopic electromagnetic calorimeter (EMC) based on NaI(Tl) counters. Until the recent EMC spectrometric channel upgrade, only the energy deposition measurement in counters was possible. A new EMC signal shaping and digitizing electronics based on FADC allows us to obtain also the event time structure. The new electronics and supporting software, including digital signal processing algorithms, are used for data taking in the ongoing experiment. We discuss the amplitude and time extraction algorithms, the new system performance on experimental events and physical analysis applications.

قيم البحث

اقرأ أيضاً

151 - A.A. Korol , N.A. Melnikova 2016
This paper presents the design, implementation and validation of the software alignment procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the SND detector which is taking data at the VEPP-2000 e^{+}e^{-}collider (BINP, Novosibirsk). This procedure is based on the mathematical model describing the relative calorimeter position. The parameter values are determined by minimizing a chi^{2} function using the difference between particle directions reconstructed in these two subdetectors for e^{+}e^{-}rightarrow e^{+}e^{-} scattering events. The results of the calibration applied to data and MC simulation fit the model well and give an improvement in particle reconstruction. They are used in data reconstruction and MC simulation.
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called heavy photon. Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeters main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. The detector is a homogeneous calorimeter, made of 442 lead-tungstate (PbWO4) scintillating crystals, each read out by an avalanche photodiode coupled to a custom trans-impedance amplifier.
This paper presents mechanical R&D for the CALICE Silicon-tungsten electromagnetic calorimeter. After the physics ECAL prototype, tested in 2006 (DESY-CERN), 2007 (CERN), 2008 (FNAL) and before the design of different modules 0 (barrel and endcap) fo r a final detector, a technological ECAL prototype, called the EUDET module, is under design in order to have a close to full scale technological solution which could be used for the final detector, taking into account future industrialisation of production.
79 - Marcel Reinhard 2009
The CALICE prototype for a Si/W electromagnetic calorimeter has been tested in large scale test beams. Several million events with electrons and hadrons of different energies and impact angles have been recorded. The energy resolution has been measur ed to be (16.6 +- 0.1)%/sqrt(E(GeV)) for the stochastic and (1.1 +- 0.1)% for the constant term with a linearity within the 1% level. The next step will be the construction of a large scale prototype which will take realistic experimental costraints into account. This module will naturally benefit from the experience gained with the first prototype.
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}rightarrow gamma+A$, where $A$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring the energy and position of the final-state $gamma$. The missing four-momentum carried away by the $A$ can be evaluated from this information and the particle mass inferred. This paper presents the design, construction, and calibration of the PADMEs electromagnetic calorimeter. The results achieved in terms of equalisation, detection efficiency and energy resolution during the first phase of the experiment demonstrate the effectiveness of the various tools used to improve the calorimeter performance with respect to earlier prototypes.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا