ترغب بنشر مسار تعليمي؟ اضغط هنا

Progress in the measurement and reduction of thermal noise in optical coatings for gravitational-wave detectors

139   0   0.0 ( 0 )
 نشر من قبل Massimo Granata
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Coating thermal noise is a fundamental limit for precision experiments based on optical and quantum transducers. In this review, after a brief overview of the techniques for coating thermal noise measurements, we present the latest world-wide research activity on low-noise coatings, with a focus on the results obtained at the Laboratoire des Mat{e}riaux Avanc{e}s. We report new updated values for the Ta$_2$O$_5$, Ta$_2$O$_5$-TiO$_2$ and SiO$_2$ coatings of the Advanced LIGO, Advanced Virgo and KAGRA detectors, and new results from sputtered Nb$_2$O$_5$, TiO$_2$-Nb$_2$O$_5$, Ta$_2$O$_5$-ZrO$_2$, MgF$_2$, AlF$_3$ and silicon nitride coatings. Amorphous silicon, crystalline coatings, high-temperature deposition, multi-material coatings and composite layers are also briefly discussed, together with the latest developments of structural analyses and models.

قيم البحث

اقرأ أيضاً

The sensitivity of current and planned gravitational wave interferometric detectors is limited, in the most critical frequency region around 100 Hz, by a combination of quantum noise and thermal noise. The latter is dominated by Brownian noise: therm al motion originating from the elastic energy dissipation in the dielectric coatings used in the interferometer mirrors. The energy dissipation is a material property characterized by the mechanical loss angle. We have identified mixtures of titanium dioxide (TiO$_2$) and germanium dioxide (GeO$_2$) that show internal dissipations at a level of 1 $times 10^{-4}$, low enough to provide almost a factor of two improvement on the level of Brownian noise with respect to the state-of-the-art materials. We show that by using a mixture of 44% TiO$_2$ and 56% GeO$_2$ in the high refractive index layers of the interferometer mirrors, it would be possible to achieve a thermal noise level in line with the design requirements. These results are a crucial step forward to produce the mirrors needed to meet the thermal noise requirements for the planned upgrades of the Advanced LIGO and Virgo detectors.
This paper focuses on the next detectors for gravitational wave astronomy which will be required after the current ground based detectors have completed their initial observations, and probably achieved the first direct detection of gravitational wav es. The next detectors will need to have greater sensitivity, while also enabling the world array of detectors to have improved angular resolution to allow localisation of signal sources. Sect. 1 of this paper begins by reviewing proposals for the next ground based detectors, and presents an analysis of the sensitivity of an 8 km armlength detector, which is proposed as a safe and cost-effective means to attain a 4-fold improvement in sensitivity. The scientific benefits of creating a pair of such detectors in China and Australia is emphasised. Sect. 2 of this paper discusses the high performance suspension systems for test masses that will be an essential component for future detectors, while sect. 3 discusses solutions to the problem of Newtonian noise which arise from fluctuations in gravity gradient forces acting on test masses. Such gravitational perturbations cannot be shielded, and set limits to low frequency sensitivity unless measured and suppressed. Sects. 4 and 5 address critical operational technologies that will be ongoing issues in future detectors. Sect. 4 addresses the design of thermal compensation systems needed in all high optical power interferometers operating at room temperature. Parametric instability control is addressed in sect. 5. Only recently proven to occur in Advanced LIGO, parametric instability phenomenon brings both risks and opportunities for future detectors. The path to future enhancements of detectors will come from quantum measurement technologies. Sect. 6 focuses on the use of optomechanical devices for obtaining enhanced sensitivity, while sect. 7 reviews a range of quantum measurement options.
We report on the results of an extensive campaign of optical and mechanical characterization of the ion-beam sputtered oxide layers (Ta$_2$O$_5$, TiO$_2$, Ta$_2$O$_5$-TiO$_2$, SiO$_2$) within the high-reflection coatings of the Advanced LIGO, Advance d Virgo and KAGRA gravitational-wave detectors: refractive index, thickness, optical absorption, composition, density, internal friction and elastic constants have been measured; the impact of deposition rate and post-deposition annealing on coating internal friction has been assessed. For Ta$_2$O$_5$ and SiO$_2$ layers, coating internal friction increases with the deposition rate, whereas the annealing treatment either erases or largely reduces the gap between samples with different deposition history. For Ta$_2$O$_5$-TiO$_2$ layers, the reduction of internal friction due to TiO$_2$ doping becomes effective only if coupled with annealing. All measured samples showed a weak dependence of internal friction on frequency ($phi_c(f) = af^{b}$, with $-0.208 < b < 0.140$ depending on the coating material considered). SiO$_2$ films showed a mode-dependent loss branching, likely due to spurious losses at the coated edge of the samples. The reference loss values of the Advanced LIGO and Advanced Virgo input (ITM) and end (ETM) mirror HR coatings have been updated by using our estimated value of Youngs modulus of Ta$_2$O$_5$-TiO$_2$ layers (120 GPa) and are about 10% higher than previous estimations.
Future ground-based gravitational-wave detectors are slated to detect black hole and neutron star collisions from the entire stellar history of the universe. To achieve the designed detector sensitivities, frequency noise from the laser source must b e reduced below the level achieved in current Advanced LIGO detectors. This paper reviews the laser frequency noise suppression scheme in Advanced LIGO, and quantifies the noise coupling to the gravitational-wave readout. The laser frequency noise incident on the current Advanced LIGO detectors is $8 times 10^{-5}~mathrm{Hz/sqrt{Hz}}$ at $1~mathrm{kHz}$. Future detectors will require even lower incident frequency noise levels to ensure this technical noise source does not limit sensitivity. The frequency noise requirement for a gravitational wave detector with arm lengths of $40~mathrm{km}$ is estimated to be $7 times 10^{-7}~mathrm{Hz/sqrt{Hz}}$. To reach this goal a new frequency noise suppression scheme is proposed, utilizing two input mode cleaner cavities, and the limits of this scheme are explored. Using this scheme the frequency noise requirement is met, even in pessimistic noise coupling scenarios.
We present the results of mechanical characterizations of many different high-quality optical coatings made of ion-beam-sputtered titania-doped tantala and silica, developed originally for interferometric gravitational-wave detectors. Our data show t hat in multi-layer stacks (like high-reflection Bragg mirrors, for example) the measured coating dissipation is systematically higher than the expectation and is correlated with the stress condition in the sample. This has a particular relevance for the noise budget of current advanced gravitational-wave interferometers, and, more generally, for any experiment involving thermal-noise limited optical cavities.
التعليقات