ترغب بنشر مسار تعليمي؟ اضغط هنا

Impact of the positive ion current on large size neutrino detectors and delayed photon emission

49   0   0.0 ( 0 )
 نشر من قبل Roberto Santorelli
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Given their small mobility coefficient in liquid argon with respect to the electrons, the ions spend a considerably longer time in the active volume. We studied the effects of the positive ion current in a liquid argon time projection chamber, in the context of massive argon experiments for neutrino physics. The constant recombination between free ions and electrons produces a quenching of the charge signal and a constant emission of photons, uncorrelated in time and space to the physical interactions. The predictions evidence some potential concerns for multi-ton argon detectors, particularly when operated on surface



قيم البحث

اقرأ أيضاً

64 - H. Bonet 2020
Intense fluxes of reactor antineutrinos offer a unique possibility to probe the fully coherent character of elastic neutrino scattering off atomic nuclei. In this regard, detectors face the challenge to register tiny recoil energies of a few keV at t he maximum. The CONUS experiment was installed in 17.1 m distance from the reactor core of the nuclear power plant in Brokdorf, Germany, and was designed to detect this neutrino interaction channel by using four 1 kg-sized point contact germanium detectors with sub-keV energy thresholds. This report describes the unique specifications addressed to the design, the research and development, and the final production of these detectors. It demonstrates their excellent electronic performance obtained during commissioning under laboratory conditions as well as during the first two years of operation at the reactor site which started on April 1, 2018. It highlights the long-term stability of different detector parameters and the achieved background levels of the germanium detectors inside the CONUS shield setup.
Dark Matter and Double Beta Decay experiments require extremely low radioactivity within the detector materials. For this purpose, the University of California, Los Angeles and Hamamatsu Photonics have developed the QUartz Photon Intensifying Detecto r (QUPID), an ultra-low background photodetector based on the Hybrid Avalanche Photo Diode (HAPD) and entirely made of ultraclean synthetic fused silica. In this work we present the basic concept of the QUPID and the testing measurements on QUPIDs from the first production line. Screening of radioactivity at the Gator facility in the Laboratori Nazionali del Gran Sasso has shown that the QUPIDs safely fulfill the low radioactive contamination requirements for the next generation zero background experiments set by Monte Carlo simulations. The quantum efficiency of the QUPID at room temperature is > 30% at the xenon scintillation wavelength. At low temperatures, the QUPID shows a leakage current less than 1 nA and a global gain of 10^5. In these conditions, the photocathode and the anode show > 95% linearity up to 1 uA for the cathode and 3 mA for the anode. The photocathode and collection efficiency are uniform to 80% over the entire surface. In parallel with single photon counting capabilities, the QUPIDs have a good timing response: 1.8 +/- 0.1 ns rise time, 2.5 +/- 0.2 ns fall time, 4.20 +/- 0.05 ns pulse width, and 160 +/- 30 ps transit time spread. The QUPIDs have also been tested in a liquid xenon environment, and scintillation light from 57Co and 210Po radioactive sources were observed.
The feasibility of a next generation neutrino observatory in Europe is being considered within the LAGUNA design study. To accommodate giant neutrino detectors and shield them from cosmic rays, a new very large underground infrastructure is required. Seven potential candidate sites in different parts of Europe and at several distances from CERN are being studied: Boulby (UK), Canfranc (Spain), Frejus (France/Italy), Pyhasalmi (Finland), Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The design study aims at the comprehensive and coordinated technical assessment of each site, at a coherent cost estimation, and at a prioritization of the sites within the summer 2010.
More target mass is required in current TPC based directional dark matter detectors for improved detector sensitivity. This can be achieved by scaling up the detector volumes, but this results in the need for more analogue signal channels. A possible solution to reducing the overall cost of the charge readout electronics is to multiplex the signal readout channels. Here, we present a multiplexer system in expanded mode based on LMH6574 chips produced by Texas Instruments, originally designed for video processing. The setup has a capability of reducing the number of readouts in such TPC detectors by a factor of 20. Results indicate that the important charge distribution asymmetry along an ionization track is retained after multiplexed signals are demultiplexed.
Gadolinium-loading of large water Cherenkov detectors is a prime method for the detection of the Diffuse Supernova Neutrino Background (DSNB). While the enhanced neutron tagging capability greatly reduces single-event backgrounds, correlated events m imicking the IBD coincidence signature remain a potentially harmful background. Neutral-Current (NC) interactions of atmospheric neutrinos potentially dominate the DSNB signal especially in the low-energy range of the observation window that reaches from about 12 to 30 MeV. The present paper investigates a novel method for the discrimination of this background. Convolutional Neural Networks (CNNs) offer the possibility for a direct analysis and classification of the PMT hit patterns of the prompt events. Based on the events generated in a simplified SuperKamiokande-like detector setup, we find that a trained CNN can maintain a signal efficiency of 96 % while reducing the residual NC background to 2 % of the original rate. Comparing to recent predictions of the DSNB signal and measurements of the NC background levels in Super-Kamiokande, the corresponding signal-to-background ratio is about 4:1, providing excellent conditions for a DSNB discovery.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا