This paper describes the performance of a prototype timing detector, based on 50 micrometer thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the pixel capacitance and the bias voltage is investigated here. A timing precision from 30 ps to 100 ps, depending on the pixel capacitance, has been measured at a bias voltage of 180 V. Timing precision has also been measured as a function of the bias voltage.

قيم البحث

اقرأ أيضاً

This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The m easurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with one of the vertices reconstructed by the CMS detectors. The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD) diamond plates and is designed to measure the protons TOF with about 50 ps time precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2 and will tag the central diffractive events up to an interaction pileup of about 1. A dedicated fast and low noise electronics for the signal amplification has been developed. The digitization of the diamond signal is performed by sampling the waveform. After introducing the physics studies that will most profit from the addition of these new detectors, we discuss in detail the optimization and the performance of the first TOF detector installed in the LHC in November 2015.
60 - Marco Mandurrino 2019
It is foreseen to significantly increase the luminosity of the LHC in order to harvest the maximum physics potential. Especially the Phase-II-Upgrade foreseen for 2023 will mean unprecedented radiation levels, significantly beyond the limits of the S ilicon trackers currently employed. All-Silicon central trackers are being studied in ATLAS, CMS and LHCb, with extremely radiation-hard Silicon sensors to be employed on the innermost layers. Within the RD50 Collaboration, a large R&D program has been underway for more than a decade across experimental boundaries to develop Silicon sensors with sufficient radiation tolerance for HL-LHC trackers. Key areas of recent RD50 research include new sensor fabrication technologies such as HV-CMOS, exploiting the wide availability of the CMOS process in the semiconductor industry at very competitive prices compared to the highly specialized foundries that normally produce particle detectors on small wafers. We also seek for a deeper understanding of the connection between the macroscopic sensor properties such as radiation-induced increase of leakage current, doping concentration and trapping, and the microscopic properties at the defect level. Another strong activity is the development of advanced sensor types like 3D Silicon detectors, designed for the extreme radiation levels expected for the vertexing layers at the HL-LHC. A further focus area is the field of LGADs, where a dedicated multiplication layer to create a high field region is built into the sensor. LGADs are characterized by a high signal also after irradiation and a very fast signal compared to traditional Silicon detectors with make them ideal candidates for ATLAS and CMS timing layers in the HL-LHC. We will present the state of the art in several Silicon detector technologies as outlined above and at radiation levels corresponding to HL-LHC fluences and partially beyond.
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and +- 220 m from IP5. This article describes in detail the working of the TOTEM detector to produce physics results in the first three years of operation and data taking at the LHC.
The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity up to 6*10^34 cm^-2 s^-1. A consequence of this increased luminosity is the expected radiation damage at 3000 fb^-1 after ten years of operation, requiring the tracking detectors to withstand fluences to over 1*10^16 1 MeV n_eq/cm^2 . In order to cope with the consequent increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk). Two proposed detectors for the ATLAS strip tracker region of the ITk were characterized at the Diamond Light Source with a 3 um FWHM 15 keV micro focused X-ray beam. The devices under test were a 320 Um thick silicon stereo (Barrel) ATLAS12 strip mini sensor wire bonded to a 130 nm CMOS binary readout chip (ABC130) and a 320 Um thick full size radial (end-cap) strip sensor - utilizing bi-metal readout layers - wire bonded to 250 nm CMOS binary readout chips (ABCN-25). A resolution better than the inter strip pitch of the 74.5 um strips was achieved for both detectors. The effect of the p-stop diffusion layers between strips was investigated in detail for the wire bond pad regions. Inter strip charge collection measurements indicate that the effective width of the strip on the silicon sensors is determined by p-stop regions between the strips rather than the strip pitch.
In order to improve the particle identification capability of the Beijing Spectrometer III (BESIII),t is proposed to upgrade the current endcap time-of-flight (ETOF) detector with multi-gap resistive plate chamber (MRPC) technology. Aiming at extendi ng ETOF overall time resolution better than 100ps, the whole system including MRPC detectors, new-designed Front End Electronics (FEE), CLOCK module, fast control boards and time to digital modules (TDIG), was built up and operated online 3 months under the cosmic ray. The main purposes of cosmic ray test are checking the detectors construction quality, testing the joint operation of all instruments and guaranteeing the performance of the system. The results imply MRPC time resolution better than 100$ps$, efficiency is about 98$%$ and the noise rate of strip is lower than 1$Hz/$($scm^{2}$) at normal threshold range, the details are discussed and analyzed specifically in this paper. The test indicates that the whole ETOF system would work well and satisfy the requirements of upgrade.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا