ترغب بنشر مسار تعليمي؟ اضغط هنا

The GALAH Survey: Relative throughputs of the 2dF fibre positioner and the HERMES spectrograph from stellar targets

210   0   0.0 ( 0 )
 نشر من قبل Jeffrey Simpson
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present an analysis of the relative throughputs of the 3.9-metre Anglo-Australian Telescopes 2dF/HERMES system, based upon spectra acquired during the first two years of the GALAH survey. Averaged spectral fluxes of stars were compared to their photometry to determine the relative throughputs of fibres for a range of fibre position and atmospheric conditions. We find that overall the throughputs of the 771 usable fibres have been stable over the first two years of its operation. About 2.5 per cent of fibres have throughputs much lower than the average. There are also a number of yet unexplained variations between the HERMES bandpasses, and mechanically & optically linked fibre groups known as retractors or slitlets related to regions of the focal plane. These findings do not impact the science that HERMES will produce.



قيم البحث

اقرأ أيضاً

WEAVE is the new wide-field spectroscopy facility for the prime focus of the William Herschel Telescope at La Palma, Spain. Its fibre positioner is essential for the accurate placement of the spectrographs 960 fibre multiplex. We provide an overview of the final assembly and metrology of the fibre positioner, and results of lab commissioning of its robot gantries. A completely new z-gantry for each positioner robot was acquired, with measurements showing a marked improvement in positioning repeatability. We also present the first results of the configuration software testing, and discuss the metrology procedures that must be repeated after the positioners arrival at the observatory.
The High Efficiency and Resolution Multi Element Spectrograph, HERMES, is a facility-class optical spectrograph for the Anglo-Australian Telescope (AAT). It is designed primarily for Galactic Archaeology, the first major attempt to create a detailed understanding of galaxy formation and evolution by studying the history of our own galaxy, the Milky Way. The goal of the GALAH survey is to reconstruct the mass assembly history of the Milky Way through a detailed chemical abundance study of one million stars. The spectrograph is based at the AAT and is fed by the existing 2dF robotic fiber positioning system. The spectrograph uses volume phase holographic gratings to achieve a spectral resolving power of 28,000 in standard mode and also provides a high-resolution mode ranging between 40,000 and 50,000 using a slit mask. The GALAH survey requires an SNR greater than 100 for a star brightness of V ?= 14 in an exposure time of one hour. The total spectral coverage of the four channels is about 100 nm between 370 and 1000 nm for up to 392 simultaneous targets within the 2-degree field of view. HERMES has been commissioned over three runs, during bright time in October, November, and December 2013, in parallel with the beginning of the GALAH pilot survey, which started in November 2013. We present the first-light results from the commissioning run and the beginning of the GALAH survey, including performance results such as throughput and resolution, as well as instrument reliability.
We present the data reduction procedures being used by the GALAH survey, carried out with the HERMES fibre-fed, multi-object spectrograph on the 3.9~m Anglo-Australian Telescope. GALAH is a unique survey, targeting 1 million stars brighter than magni tude V=14 at a resolution of 28,000 with a goal to measure the abundances of 29 elements. Such a large number of high resolution spectra necessitates the development of a reduction pipeline optimized for speed, accuracy, and consistency. We outline the design and structure of the Iraf-based reduction pipeline that we developed, specifically for GALAH, to produce fully calibrated spectra aimed for subsequent stellar atmospheric parameter estimation. The pipeline takes advantage of existing Iraf routines and other readily available software so as to be simple to maintain, testable and reliable. A radial velocity and stellar atmospheric parameter estimator code is also presented, which is used for further data analysis and yields a useful verification of the reduction quality. We have used this estimator to quantify the data quality of GALAH for fibre cross-talk level ($lesssim0.5$%) and scattered light ($sim5$ counts in a typical 20 minutes exposure), resolution across the field, sky spectrum properties, wavelength solution reliability (better than $1$ $mathrm{km s^{-1}}$ accuracy) and radial velocity precision.
Fibre Multi-Object Spectrograph (FMOS) is the first near-infrared instrument with a wide field of view capable of acquiring spectra simultaneously from up to 400 objects. It has been developed as a common-use instrument for the F/2 prime-focus of the Subaru Telescope. The field coverage of 30 diameter is achieved using a new 3-element corrector optimized in the near-infrared (0.9-1.8um) wavelength range. Due to limited space at the prime-focus, we have had to develop a novel fibre positioner called Echidna together with two OH-airglow suppressed spectrographs. FMOS consists of three subsystems: the prime focus unit for IR, the fibre positioning system/connector units, and the two spectrographs. After full systems integration, FMOS was installed on the telescope in late 2007. Many aspects of performance were checked through various test and engineering observations. In this paper, we present the optical and mechanical components of FMOS and show the results of our on-sky engineering observations to date.
CYCLOPS2 is an upgrade for the UCLES high resolution spectrograph on the Anglo-Australian Telescope, scheduled for commissioning in semester 2012A. By replacing the 5 mirror Coude train with a Cassegrain mounted fibre-based image slicer CYCLOPS2 simu ltaneously provides improved throughput, reduced aperture losses and increased spectral resolution. Sixteen optical fibres collect light from a 5.0 arcsecond^2 area of sky and reformat it into the equivalent of a 0.6 arcsecond wide slit, delivering a spectral resolution of R = 70000 and up to twice as much flux as the standard 1 arcsecond slit of the Coude train. CYCLOPS2 also adds support for simultaneous ThAr wavelength calibration via a dedicated fibre. CYCLOPS2 consists of three main components, the fore-optics unit, fibre bundle and slit unit. The fore optics unit incorporates magnification optics and a lenslet array and is designed to mount to the CURE Cassegrain instrument interface, which provides acquisition, guiding and calibration facilities. The fibre bundle transports the light from the Cassegrain focus to the UCLES spectrograph at Coude and also includes a fibre mode scrambler. The slit unit consists of the fibre slit and relay optics to project an image of the slit onto the entrance aperture of the UCLES spectrograph. CYCLOPS2 builds on experience with the first generation CYCLOPS fibre system, which we also describe in this paper. We present the science case for an image slicing fibre feed for echelle spectroscopy and describe the design of CYCLOPS and CYCLOPS2.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا