ترغب بنشر مسار تعليمي؟ اضغط هنا

Positron plasma diagnostics and temperature control for antihydrogen production

76   0   0.0 ( 0 )
 نشر من قبل Marco Amoretti
 تاريخ النشر 2003
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Production of antihydrogen atoms by mixing antiprotons with a cold, confined, positron plasma depends critically on parameters such as the plasma density and temperature. We discuss non-destructive measurements, based on a novel, real-time analysis of excited, low-order plasma modes, that provide comprehensive characterization of the positron plasma in the ATHENA antihydrogen apparatus. The plasma length, radius, density, and total particle number are obtained. Measurement and control of plasma temperature variations, and the application to antihydrogen production experiments are discussed.



قيم البحث

اقرأ أيضاً

202 - Munshi G. Mustafa 2008
Ultra-intense lasers are expected to produce, in near future, relativistic electron-positron plasma droplets. Considering the local photon production rate in complete leading order in quantum electrodynamics (QED), we point out that these droplets are interesting sources of gamma ray flashes
358 - P. H. Donnan 2012
We present a scheme for laser cooling applicable for an extremely dilute sample of magnetically trapped antihydrogen atoms($bar{H}$). Exploiting and controlling the dynamical coupling between the $bar{H}$s motional degrees of freedom in a magnetic tr ap, three-dimensional cooling can be achieved from Doppler cooling on one dimension using the $1s_{1/2}-2p_{3/2}$ transition. The lack of three-dimensional access to the trapped $bar{H}$ and the nearly separable nature of the trapping potential leads to difficulties in cooling. Using realistic models for the spatial variation of the magnetic fields, we find that it should be possible to cool the $bar{H}$s to $sim 20$ mK even with these constraints.
Recently, antihydrogen atoms were trapped at CERN in a magnetic minimum (minimum-B) trap formed by superconducting octupole and mirror magnet coils. The trapped antiatoms were detected by rapidly turning off these magnets, thereby eliminating the mag netic minimum and releasing any antiatoms contained in the trap. Once released, these antiatoms quickly hit the trap wall, whereupon the positrons and antiprotons in the antiatoms annihilated. The antiproton annihilations produce easily detected signals; we used these signals to prove that we trapped antihydrogen. However, our technique could be confounded by mirror-trapped antiprotons, which would produce seemingly-identical annihilation signals upon hitting the trap wall. In this paper, we discuss possible sources of mirror-trapped antiprotons and show that antihydrogen and antiprotons can be readily distinguished, often with the aid of applied electric fields, by analyzing the annihilation locations and times. We further discuss the general properties of antiproton and antihydrogen trajectories in this magnetic geometry, and reconstruct the antihydrogen energy distribution from the measured annihilation time history.
109 - V. N. Rai 2014
This paper presents the basic concept of various plasma diagnostics used for the study of plasma characteristics in different plasma experiments ranging from low temperature to high energy density plasma.
The expansion dynamics of hot electron-positron-photon plasma droplets is dealt with within relativistic hydrodynamics. Such droplets, envisaged to be created in future experiments by irradiating thin foils with counter-propagating ultra-intense lase r beams, are sources of flashes of gamma radiation. Warm electron-positron plasma droplets may be identified and characterized by a broadened 511 keV line.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا