ترغب بنشر مسار تعليمي؟ اضغط هنا

RF Processing of X-band Accelerator Structures at the NLCTA

75   0   0.0 ( 0 )
 نشر من قبل Chris Adolphsen
 تاريخ النشر 2000
  مجال البحث فيزياء
والبحث باللغة English
 تأليف C. Adolphsen




اسأل ChatGPT حول البحث

During the initial phase of operation, the linacs of the Next Linear Collider (NLC) will contain roughly 5000 X-Band accelerator structures that will accelerate beams of electrons and positrons to 250 GeV. These structures will nominally operate at an unloaded gradient of 72 MV/m. As part of the NLC R&D program, several prototype structures have been built and operated at the Next Linear Collider Test Accelerator (NLCTA) at SLAC. Here, the effect of high gradient operation on the structure performance has been studied. Significant progress was made during the past year after the NLCTA power sources were upgraded to reliably produce the required NLC power levels and beyond. This paper describes the structures, the processing methodology and the observed effects of high gradient operation.

قيم البحث

اقرأ أيضاً

264 - C. Adolphsen 2001
RF processing studies of 1.8-m X-band (11.4 GHz) traveling wave structures at the Next Linear Collider Test Accelerator (NLCTA) have revealed breakdown-related damage at gradients lower than expected from earlier tests with standing wave and shorter, lower group velocity traveling wave structures. To understand this difference, a series of structures with different group velocities and lengths are being processed. In parallel, efforts are being made to improve processing procedures and to reduce structure contaminants and absorbed gases. This paper presents results from these studies.
Front end of a CW linac of the Project X contains an H source, an RFQ, a medium energy transport line with the beam chopper, and a SC low-beta linac that accelerates H- from 2.5 MeV to 160 MeV. SC Single Spoke Resonators (SSR) will be used in the lin ac, because Fermilab already successfully developed and tested a SSR for beta=0.21. Two manufactured cavities achieve 2.5 times more than design accelerating gradients. One of these cavities completely dressed, e.g. welded to helium vessel with integrated slow and fast tuners, and tested in CW regime. Successful tests of beta=0.21 SSR give us a confidence to use this type of cavity for low beta (0.117) and for high-beta (0.4) as well. Both types of these cavities are under development. In present report the basic constrains, parameters, electromagnetic and mechanical design for all the three SSR cavities, and first test results of beta=0.21 SSR are presented.
In the development of high efficiency and high gradient RF-accelerators, RF waveguides and cavities have been designed with Photonic Band Gap (PBG) and fishnet- metamaterial structures. The designed structures are comprised of a periodically corrugat ed channel sandwiched between two photonic crystal slabs with alternating high to low dielectric constants and a multi-cell cavity-resonator designed with fishnet-metamaterial apertures. The structural designs of our interest are intended to only allow an operating-mode or -band within a narrow frequency range to propagate. The simulation analysis shows that trapped non-PBG modes are effectively suppressed down to ~ -14.3 dB/cm, while PBG modes propagated with ~2 dB of insertion loss, corresponding to ~1.14 dB/cm attenuation. The pre- liminary modeling analysis on the fishnet-embedded cavity shows noticeable improvement of Q-factor and field gradient of the operating mode (TM010) compared to those of typical pillbox- or PBG-cavities. Fabrication of the Ka-band PBG-waveguide and S-band fishnet cavity structures is currently underway and they will be tested with a microwave test bench/8510C Network Analyzer and 5.5 MW S-band klystron. These structures can be applied to stable short-bunch formation and mono chromatic radiation in high frequency accelerators.
The Advanced Superconducting Test Acccelerator (ASTA) is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration sectio n consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beamlines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating a 750-MeV electron beam with ILC beam intensity. An expansion of this facility was recently completed that will provide the capability to upgrade the accelerator to a total beam energy of 1.5-GeV. Two new buildings were also constructed adjacent to the ASTA facility to house a new cryogenic plant and multiple superconducting RF (SRF) cryomodule test stands. In addition to testing accelerator components, this facility will be used to test RF power systems, instrumentation, and control systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.
87 - J. P. Edelen 2018
The PIP-II accelerator is a proposed upgrade to the Fermilab accelerator complex that will replace the existing, 400 MeV room temperature LINAC with an 800 MeV superconducting LINAC. Part of this upgrade includes a new injection scheme into the boost er that levies tight requirements on the LLRF control system for the cavities. In this paper we discuss the challenges of the PIP-II accelerator and the present status of the LLRF system for this project.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا