After an introduction to the sequential version of FORM and the mechanisms behind, we report on the status of our project of parallelization. We have now a parallel version of FORM running on Cluster- and SMP-architectures. This version can be used to run arbitrary FORM programs in parallel.
This paper shows a brief review on CDCC and the microscopic reaction theory as a fundamental theory of CDCC. The Kerman-McManus-Thaler theory for nucleon-nucleus scattering is extended to nucleus-nucleus scattering. New development of four-body CDCC
is presented. An accurate method of treating inclusive reactions is presented as an extension of CDCC and the Glauber model.
We present a concise review of the recent development of relativistic hydrodynamics and its applications to heavy-ion collisions. Theoretical progress on the extended formulation of hydrodynamics towards out-of-equilibrium systems is addressed, empha
sizing the so-called attractor solution. On the other hand, recent phenomenological improvements in the hydrodynamic modeling of heavy-ion collisions with respect to the ongoing Beam Energy Scan program, the quantitative characterization of transport coefficients in the three-dimensionally expanding quark-gluon plasma, the fluid description of small colliding systems, and some other interdisciplinary connections are discussed.
A description of the intermediate and high energy hadronic interaction models used in the FLUKA code is given. Benchmarking against experimental data is also reported in order to validate the model performances. Finally the most recent developments a
nd perspectives for nucleus-nucleus interactions are described together with some comparisons with experimental data.
Today the Hybrid Photon Detector (HPD) is one of the few low light level (LLL) sensors that can provide an excellent single and multiple photoelectron (ph.e.) amplitude resolution. The recently developed HPDs for the MAGIC telescope project with a Ga
AsP photocathode, namely the R9792U-40, provide a peak quantum efficiency (QE) of more than 50% and a pulse width of ~2 nsec. In addition, the afterpulsing rate of these tubes is very low compared to that of conventional photomultiplier tubes (PMTs), i.e. the value is ~300 times lower. Photocathode aging measurements showed life time of more than 10 years under standard operating conditions of the Cherenkov Telescopes. Here we want to report on the recent progress with the above mentioned HPDs.
سجل دخول لتتمكن من نشر تعليقات
التعليقات
جاري جلب التعليقات
حدث خطأ أثناء جلب التعليقات!
حذف التعليق
هل أنت متأكد أنك ترغب في حذف تعليقك ؟
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها