ترغب بنشر مسار تعليمي؟ اضغط هنا

M31 Globular Cluster X-ray Sources: XMM-Newton and Chandra results

78   0   0.0 ( 0 )
 نشر من قبل Sergey Trudolyubov
 تاريخ النشر 2004
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

(Abridged) We present the results of M31 globular cluster (GC) X-ray source survey, based on the data of XMM-Newton and Chandra observations covering ~6100 sq.arcmin of M31. We detected 43 X-ray sources coincident with globular cluster candidates from optical surveys. The estimated isotropic X-ray luminosities of GC sources lie between ~10e35 and ~10e39 erg/s in the 0.3 - 10 keV energy band. The spectral properties and variability of M31 GC X-ray sources are consistent with that derived for the LMXBs in the bulges of M31 and Milky Way. We found that ~80% of the M31 GC sources with multiple flux measurements available show significant variability on a time scales from days to years. The X-ray luminosity function of GC sources is found to be significantly different from that of the point sources in the bulge and disk of M31 and that of the Galactic GC X-ray sources. GC sources make dominant contribution to the bright source counts in the areas of M31 covered by the survey: ~40% of the total number of sources with luminosities above 10e37 ergs/s reside in GCs with fraction of GC sources rising to 67-90% for the luminosities above 10e38 ergs/s. The contribution of the GC sources to the total number of bright sources found in M31 is much higher than in the Milky Way galaxy, but surprisingly close to that of the early-type galaxies. The brightest M31 GC sources tend to reside at large galactocentric distances outside the central bulge. We found that globular clusters hosting bright X-ray sources are optically brighter and more metal rich than the rest of M31 globular clusters. The brightest sources with luminosities above ~10e38 ergs/s show tendency to reside in more metal poor clusters.

قيم البحث

اقرأ أيضاً

We present the results of the ongoing XMM-Newton survey of M31. 17 X-ray sources detected in the survey have bright radio counterparts, and 15 X-ray sources coincide with SNR candidates from optical and radio surveys. 15 out of 17 sources with radio counterparts, not SNR candidates, have spectral properties similar to that observed for background radio galaxies/quasars or Crab-like supernova remnants located in M31. The remaining two sources, XMMU J004046.8+405525 and XMMU J004249.1+412407, have soft X-ray spectra, and are associated with spatially resolved H-alpha emission regions, which makes them two new SNR candidates in M31. The observed absorbed X-ray luminosities of SNR candidates in our sample range from 1e35 to 5e36 ergs/s, assuming the distance of 760 kpc. Most of the SNR candidates detected in our survey have soft X-ray spectra. The spectra of the brightest sources show presence of emission lines and can be fit by thermal plasma models with kT~0.1-0.4 keV. The results of spectral fitting of SNR candidates suggest that most of them should be located in a relatively low density regions. We show that X-ray color-color diagrams can be useful tool for distinguishing between intrinsically hard background radio sources and Crab-like SNR and thermal SNR in M31 with soft spectra.
We present the X-ray spectra of 86 optically-identified sources in the 13H XMM-Newton/Chandra deep field which have >70 X-ray counts. The sample consists of 50 broad line AGN, 25 narrow emission line galaxies, 6 absorption line galaxies, and 5 Galact ic stars. The majority (42/50) of the broad line AGN have X-ray spectra which are consistent with a power law shape. They have a mean photon index of Gamma = 2.0 +- 0.1 and an intrinsic dispersion sigma = 0.4 +- 0.1. Five BLAGN show a deficit of soft X-rays, indicating absorption. Significant absorption is more common in the narrow emission line galaxies (13/25) and absorption line galaxies (2/6) than in the broad line AGN (5/50), but is not universal in any of these classes of object. The majority of the 20 absorbed sources have X-ray spectra consistent with a simple cold photoelectric absorber, but 6/20 require more complex models with either an additional component of soft X-ray emitting plasma, or an ionised absorber. Of the 16 galaxies which do not show evidence for X-ray absorption, only 2 objects are likely to be powered by star formation, and both have 2-10 keV X-ray luminosities of <= 10^40 cgs. The X-ray emission in the other 14 unabsorbed NELGs and galaxies is most likely powered by AGN, which are not detected in the optical because they are outshone by their luminous host galaxies. The Galactic stars show multi-temperature thermal spectra which peak between 0.5 and 1 keV. Star/AGN discrimination is possible for 4 of the 5 stars solely from their X-ray spectra.
Power density spectra (PDS) that are characteristic of low mass X-ray binaries (LMXBs) have been previously reported for M31 X-ray sources observed by XMM-Newton. However, we have recently discovered that these PDS are false positives resulting from the improper manipulation of non-simultaneous lightcurves. The lightcurves produced by the XMM-Newton Science Analysis Software (SAS) are non-synchronised by default. This affects not only the combination of lightcurves from the three EPIC detectors (MOS1, MOS2 and pn), but also background subtraction in the same CCD. It is therefore imperative that all SAS-generated lightcurves are synchronised by time filtering, even if the whole observation is to be used. We combined simulated lightcurves at various intensities with various offsets and found that the artefact is more dependent on the offset than the intensity. While previous timing results from M31 have been proven wrong, and also the broken power law PDS in NGC 4559 ULX-7, XMM-Newton was able to detect aperiodic variability in just 3 ks of observations of NGC 5408 ULX1. Hence XMM-Newton remains a viable tool for analysing variability in extra-galactic X-ray sources.
We present the results of XMM-Newton survey of the northern part of the disk of M31. The results of a spectral and timing analysis of the thirty seven brightest sources are presented. Combining the results of X-ray analysis with available data at oth er wavelengths, we were able to classify ~50%, or 19 out of 37 sources. Two sources in our sample were previously unknown: the hard X-ray source XMMU J004415.8+413057 and a transient supersoft source XMMUJ004414.1+412206. We report the discovery of possible X-ray pulsations from the source XMMUJ004415.8+413057 with a period of 197 s. The spectral and timing properties of XMMU J004415.8+413057 make it first accreting X-ray pulsar candidate detected in M31. We report on the first unambiguous detection of the soft unresolved X-ray emission from the disk of M31. The unresolved emission follows the pattern of the spiral arms and can be traced up to distance of ~0.5 deg (~7 kpc at 760 kpc) from the center of the galaxy. The spectrum of the unresolved emission shows dominant soft thermal component which can be fitted with a ~0.3 keV optically thin thermal plasma emission models. We suggest that significant part of this diffuse soft X-ray component may represent hot diffuse gas in the spiral arms of M31 and emission from normal stars in the disk of M31.
The archival XMM-Newton data of the central region of M31 were analyzed for diffuse X-ray emission. Point sources with the 0.5--10 keV luminosity exceeding $sim 4 times 10^{35}$ erg s$^{-1}$ were detected. Their summed spectra are well reproduced by a combination of a disk black-body component and a black-body component, implying that the emission mainly comes from an assembly of luminous low-mass X-ray binaries. After excluding these point sources, spectra were accumulated over a circular region of $6arcmin$ (1.2 kpc) centered on the nucleus. In the energy range above 2 keV, these residual spectra are understood mainly as contributions of unresolved faint sources and spill-over of photons from the excluded point sources. There is in addition a hint of a $sim 6.6$ keV line emission, which can be produced by a hot (temperature several keV) thin-thermal plasma. Below 2 keV, the spectra involve three additional softer components expressed by thin-thermal plasma emission models, of which the temperatures are $sim 0.6$, $sim 0.3$, and $sim 0.1$ keV. Their 0.5--10 keV luminosities within 6$arcmin$ are measured to be $sim 1.2 times 10^{38}$ erg s$^{-1}$, $sim 1.6 times 10^{38}$ erg s$^{-1}$, and $sim 4 times 10^{37}$ erg s$^{-1}$ in the order of decreasing temperature. The archival Chandra data of the central region of M31 yielded consistent results. By incorporating different annular regions, all the three softer thermal components were confirmed to be significantly extended. These results are compared with reports from previous studies. A discussion is presented on the origin of each thermal emission component.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا