ترغب بنشر مسار تعليمي؟ اضغط هنا

Astronomical x-ray polarimetry based on photoelectric effect with microgap detectors

80   0   0.0 ( 0 )
 نشر من قبل Soffitta
 تاريخ النشر 2000
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Paolo Soffitta




اسأل ChatGPT حول البحث

The polarisation of x-ray photons can be determined by measuring the direction of emission of a K-shell photoelectron. Effective exploitation of this effect below 10 keV would allow development of a highly sensitive x-ray polarimeter dedicated in particular to x-ray astronomy observations. Only with the advent of finely segmented gas detectors was it possible to detect polarisation sensitivity based on the photoelectric effect in this energy range. Simulation and measurements at 5.4 and 8.04 keV with a microgap gas counter, using both a polarised and an unpolarised x-ray source, showed that the photoelectron track in a neon-based gas mixture retains the memory of the polarisation of the incoming photons. Possible experiments aimed at galactic/extragalactic sources and solar flares are considered and their sensitivity to these sources is calculated.

قيم البحث

اقرأ أيضاً

81 - E. Costa 2002
X-ray Polarimetry is almost as old as X-ray Astronomy. Since the first discovery of X-ray sources theoretical analysis suggested that a high degree of linear polarization could be expected due either to the, extremely non thermal, emission mechanism or to the transfer of radiation in highly asymmetric systems. The actual implementation of this subtopic was, conversely, relatively deceiving. This is mainly due to the limitation of the conventional techniques based on the Bragg diffraction at 45deg, or on Thomson scattering around 90deg. Acually no X-ray Polarimeter has been launched since 25 years. Nevertheless the expectations from such measurement on several astrophysical targets including High and Low Mass X-Ray Binaries, isolated neutron Stars, Galactic and Extragalactic Black Holes is extremely attractive. We developed a new technique to measure the linear polarization of X-ray sources. It is based on the visualization of photoelectron tracks in a, finely subdivided, gas filled detector (micropattern). The initial direction of the photoelectron is derived and from the angular distribution of the tracks the amount and angle of polarization is computed. This technique can find an optimal exploitation in the focus of XEUS-1. Even in a very conservative configuration (basically the already existing prototype) the photoelectric polarimeter could perform polarimetry at % level on many AGNs. Further significant improvements can be expected from a technological development on the detector and with the use of XEUS-2 telescope.
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (AS IC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting electrode and the amplifying, shaping and charge measuring front-end electronics. The CMOS chip has the top metal layer patterned in a matrix of 80 micron pitch hexagonal pixels, each of them directly connected to the underneath electronics chain which has been realized in the remaining five layers of the 0.35 micron VLSI technology. Results from tests of a first prototype of such detector with 2k pixels and a full scale version with 22k pixels are presented. The application of this device for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation is shown. Results from a full MonteCarlo simulation for two astronomical sources, the Crab Nebula and the Hercules X1, are also reported.
67 - Philip Kaaret 2014
We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors hav e enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band soft X-ray polarimeters based on Bragg reflection. Developments in scintillator and solid-state hard X-ray detectors facilitate construction of both modular, large area Compton scattering polarimeters and compact devices suitable for use with focusing X-ray telescopes.
375 - A. Ludu , J. A. Morris , C. Rugina 2019
We explore a counterfactual protocol for energy transfer. A modified version of a Mach-Zehnder interferometer dissociates a photons position and energy into separate channels, resulting in a photoelectric effect in one channel without the absorption of a photon. We use the quantum Zeno effect to extend our results by recycling the same photon through the system and obtain a stream of photoelectrons. If dissociation of properties such as energy can be demonstrated experimentally, there may be a variety of novel energy-related applications that may arise from the capacity to do non-local work. The dissociation of intrinsic properties, like energy, from elementary particles may also lead to theoretical discussions of the constitution of quantum objects.
Since the initial exploration of soft gamma-ray sky in the 60s, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation mechanisms at work in sources such as neutrons stars and black holes are still unclear. The polarization state of the radiation is an observational parameter which brings key additional information about the physical process. This is why most of the projects for the next generation of space missions covering the tens of keV to the MeV region require a polarization measurement capability. A key element enabling this capability is a detector system allowing the identification and characterization of Compton interactions as they are the main process at play. The hard X-ray imaging spectrometer module, developed in CEA with the generic name of Caliste module, is such a detector. In this paper, we present experimental results for two types of Caliste-256 modules, one based on a CdTe crystal, the other one on a CdZnTe crystal, which have been exposed to linearly polarized beams at the European Synchrotron Radiation Facility. These results, obtained at 200-300 keV, demonstrate their capability to give an accurate determination of the polarization parameters (polarization angle and fraction) of the incoming beam. Applying a selection to our data set, equivalent to select 90 degrees Compton scattered interactions in the detector plane, we find a modulation factor Q of 0.78. The polarization angle and fraction are derived with accuracies of approximately 1 degree and 5%. The modulation factor remains larger than 0.4 when essentially no selection is made at all on the data. These results prove that the Caliste-256 modules have performances allowing them to be excellent candidates as detectors with polarimetric capabilities, in particular for future space missions.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا