Forced oscillation (FO) is a significant concern threating the power system stability. Its mechanisms are mostly studied via linear models. However, FO amplitude is increasing, e.g., Nordic and Western American FOs, which can stimulate power system nonlinearity. Hence, this paper incorporates nonlinearity in FO mechanism analysis. The multi-scale technique is employed in solving the forced oscillation equation to handle the quadratic nonlinearity. The amplitude-frequency characteristic curves and first-order approximate expressions are derived. The frequency deviation and jumping phenomenon caused by nonlinearity are discovered and further analyzed by comparing with linear models. This paper provides a preliminary research for nonlinear FOs of power system, and more characteristics should be further analysis in the near future.

قيم البحث

اقرأ أيضاً

Non-stationary forced oscillations (FOs) have been observed in power system operations. However, most detection methods assume that the frequency of FOs is stationary. In this paper, we present a methodology for the analysis of non-stationary FOs. Fi rstly, Fourier synchrosqueezing transform (FSST) is used to provide a concentrated time-frequency representation of the signals that allows identification and retrieval of non-stationary signal components. To continue, the Dissipating Energy Flow (DEF) method is applied to the extracted components to locate the source of forced oscillations. The methodology is tested using simulated as well as real PMU data. The results show that the proposed FSST-based signal decomposition provides a systematic framework for the application of DEF Method to non-stationary FOs.
We employ a novel data-enabled predictive control (DeePC) algorithm in voltage source converter (VSC) based high-voltage DC (HVDC) stations to perform safe and optimal wide-area control for power system oscillation damping. Conventional optimal wide- area control is model-based. However, in practice detailed and accurate parametric power system models are rarely available. In contrast, the DeePC algorithm uses only input/output data measured from the unknown system to predict the future trajectories and calculate the optimal control policy. We showcase that the DeePC algorithm can effectively attenuate inter-area oscillations even in the presence of measurement noise, communication delays, nonlinear loads and uncertain load fluctuations. We investigate the performance under different matrix structures as data-driven predictors. Furthermore, we derive a novel Min-Max DeePC algorithm to be applied independently in multiple VSC-HVDC stations to mitigate inter-area oscillations, which enables decentralized and robust optimal wide-area control. Further, we discuss how to relieve the computational burden of the Min-Max DeePC by reducing the dimension of prediction uncertainty and how to leverage disturbance feedback to reduce the conservativeness of robustification. We illustrate our results with high-fidelity, nonlinear, and noisy simulations of a four-area test system.
Location of non-stationary forced oscillation (FO) sources can be a challenging task, especially in cases under resonance condition with natural system modes, where the magnitudes of the oscillations could be greater in places far from the source. Th erefore, it is of interest to construct a global time-frequency (TF) representation (TFR) of the system, which can capture the oscillatory components present in the system. In this paper we develop a systematic methodology for frequency identification and component filtering of non-stationary power system forced oscillations (FO) based on multi-channel TFR. The frequencies of the oscillatory components are identified on the TF plane by applying a modified ridge estimation algorithm. Then, filtering of the components is carried out on the TF plane applying the anti-transform functions over the individual TFRs around the identified ridges. This step constitutes an initial stage for the application of the Dissipating Energy Flow (DEF) method used to locate FO sources. Besides, we compare three TF approaches: short-time Fourier transform (STFT), STFT-based synchrosqueezing transform (FSST) and second order FSST (FSST2). Simulated signals and signals from real operation are used to show that the proposed method provides a systematic framework for identification and filtering of power systems non-stationary forced oscillations.
This experiment demonstrates to engineering students that control system and power system theory are not orthogonal, but highly interrelated. It introduces a real-world power system problem to enhance time domain State Space Modelling (SSM) skills of students. It also shows how power quality is affected with real-world scenarios. Power system was modeled in State Space by following its circuit topology in a bottom-up fashion. At two different time instances of the power generator sinusoidal wave, the transmission line was switched on. Fourier transform was used to analyze resulting line currents. It validated the harmonic components, as expected, from power system theory. Students understood the effects of switching transients at various times on supply voltage sinusoid within control theory and learned time domain analysis. They were surveyed to gauge their perception of the project. Results from a before/after assessment analyzed using T-Tests showed a statistically significant enhanced learning in SSM.
135 - Nima Safari , George Price , 2020
This paper presents lessons learned to date during the Coronavirus Disease 2019 (COVID-19) pandemic from the viewpoint of Saskatchewan power system operations. A load estimation approach is developed to identify how the closures affecting businesses, schools, and other non-critical businesses due to COVID-19 changed the electricity consumption. Furthermore, the impacts of COVID-19 containment measures and re-opening phases on load uncertainty are examined. Changes in CO2 emissions resulting from an increased proportion of renewable energy generation and the change in load pattern are discussed. In addition, the influence of COVID-19 on the balancing authoritys power control performance is investigated. Analyses conducted in the paper are based upon data from SaskPower corporation, which is the principal electric utility in Saskatchewan, Canada. Some recommendations for future power system operation and planning are developed.