ترغب بنشر مسار تعليمي؟ اضغط هنا

Toward Efficient Wide-Area Identification of Multiple Element Contingencies in Power Systems

108   0   0.0 ( 0 )
 نشر من قبل Hao Huang
 تاريخ النشر 2021
والبحث باللغة English




اسأل ChatGPT حول البحث

Power system N-x contingency analysis has inherent challenges due to its combinatorial characteristic where outages grow exponentially with the increase of x and N. To address these challenges, this paper proposes a method that utilizes Line Outage Distribution Factors (LODFs) and group betweenness centrality to identify subsets of critical branches. The proposed LODF metrics are used to select the high-impact branches. Based on each selected branch, the approach constructs the subgraph with parameters of distance and search level, while using branches LODF metrics as the weights. A key innovation of this work is the use of the distance and search level parameters, which allow the subgraph to identify the most coupled critical elements that may be far away from a selected branch. The proposed approach is validated using the 200- and 500-bus test cases, and results show that the proposed approach can identify multiple N-x contingencies that cause violations.

قيم البحث

اقرأ أيضاً

This paper presents a new phasor measurement unit (PMU)-based wide-area damping control (WADC) method to suppress the critical inter-area modes of large-scale power systems. Modal participation factors, estimated by a practically model-free system id entification approach, are used to select the most suitable synchronous generators for control through the proposed WADC algorithm. It is shown that multiple inter-area modes can be sufficiently damped by the proposed approach without affecting the rest of the modes, while only a few machines are needed to perform the control. The proposed technique is applied to the IEEE 68-bus and the IEEE 145-bus systems, including the test cases with PMU measurement noise and with missing PMUs. The simulation results clearly demonstrate the good adaptivity of the control strategy subjected to network model changes, its effective damping performance comparing to power system stabilizers (PSSs), and its great potential for near real-time implementation.
In this paper, a phasor measurement unit (PMU)-based wide-area damping control method is proposed to damp the interarea oscillations that threaten the modern power system stability and security. Utilizing the synchronized PMU data, the proposed almos t model-free approach can achieve an effective damping for the selected modes using a minimum number of synchronous generators. Simulations are performed to show the validity of the proposed wide-area damping control scheme.
The reduced inertia levels in low-carbon power grids necessitate explicit constraints to limit frequencys nadir and rate of change during scheduling. This can result in significant curtailment of renewable energy due to the minimum generation of ther mal plants that are needed to provide frequency response (FR) and inertia. Additional consideration of fast FR, a dynamically reduced largest loss and under frequency load shedding (UFLS) allows frequency security to be achieved more cost effectively. This paper derives a novel nadir constraint from the swing equation that, for the first time, provides a framework for the optimal comparison of all these services. We demonstrate that this constraint can be accurately and conservatively approximated for moderate UFLS levels with a second order cone, resulting in highly tractable convex problems. Case studies performed on a Great Britain 2030 system demonstrate that UFLS as an option to contain single plant outages can reduce annual operational costs by up to {pounds}559m, 52% of frequency security costs. The sensitivity of this value to wind penetration, abundance of alternative frequency services, UFLS amount and cost is explored.
We study identification of linear systems with multiplicative noise from multiple trajectory data. A least-squares algorithm, based on exploratory inputs, is proposed to simultaneously estimate the parameters of the nominal system and the covariance matrix of the multiplicative noise. The algorithm does not need prior knowledge of the noise or stability of the system, but requires mild conditions of inputs and relatively small length for each trajectory. Identifiability of the noise covariance matrix is studied, showing that there exists an equivalent class of matrices that generate the same second-moment dynamic of system states. It is demonstrated how to obtain the equivalent class based on estimates of the noise covariance. Asymptotic consistency of the algorithm is verified under sufficiently exciting inputs and system controllability conditions. Non-asymptotic estimation performance is also analyzed under the assumption that system states and noise are bounded, providing vanishing high-probability bounds as the number of trajectories grows to infinity. The results are illustrated by numerical simulations.
This paper proposes a novel online measurement-based Wide-Area Voltage Control (WAVC) method using Phasor Measurement Unit (PMU) data in power systems with Flexible AC Transmission System (FACTS) devices. As opposed to previous WAVC methods, the prop osed WAVC does not require any model knowledge or the participation of all buses and considers both active and reactive power perturbations. Specifically, the proposed WAVC method exploits the regression theorem of the Ornstein-Uhlenbeck process to estimate the sensitivity matrices through PMU data online, which are further used to design and apply the voltage regulation by updating the reference points of FACTS devices. Numerical results on the IEEE 39- Bus and IEEE 68-Bus systems demonstrate that the proposed model-free WAVC can provide effective voltage control in various network topologies, different combinations of voltage-controlled and voltage-uncontrolled buses, under measurement noise, and in case of missing PMUs. Particularly, the proposed WAVC algorithm may outperform the model-based WAVC when an undetected topology change happens.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا