ترغب بنشر مسار تعليمي؟ اضغط هنا

Independent Normalization for $gamma$-ray Strength Functions: The Shape Method

585   0   0.0 ( 0 )
 نشر من قبل Mathis Wiedeking
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Shape method, a novel approach to obtain the functional form of the $gamma$-ray strength function ($gamma$SF) in the absence of neutron resonance spacing data, is introduced. When used in connection with the Oslo method the slope of the Nuclear Level Density (NLD) is obtained simultaneously. The foundation of the Shape method lies in the primary $gamma$-ray transitions which preserve information on the functional form of the $gamma$SF. The Shape method has been applied to $^{56}$Fe, $^{92}$Zr, $^{164}$Dy, and $^{240}$Pu, which are representative cases for the variety of situations encountered in typical NLD and $gamma$SF studies. The comparisons of results from the Shape method to those from the Oslo method demonstrate that the functional form of the $gamma$SF is retained regardless of nuclear structure details or $J^pi$ values of the states fed by the primary transitions.



قيم البحث

اقرأ أيضاً

A new method for the determination of electric signal time-shifts is introduced. As the Kolmogorov-Smirnov test, it is based on the comparison of the cumulative distribution functions of the reference signal with the test signal. This method is very fast and thus well suited for on-line applications. It is robust to noise and its performances in terms of precision are excellent for time-shifts ranging from a fraction to several sample durations. PACS. 29.40.Gx (Tracking and position-sensitive detectors), 29.30.Kv (X- and -ray spectroscopy), 07.50.Qx (Signal processing electronics)
A new data analysis method is developed for the angle resolving silicon telescope introduced at the neutron time of flight facility n_TOF at CERN. The telescope has already been used in measurements of several neutron induced reactions with charged p articles in the exit channel. The development of a highly detailed method is necessitated by the latest joint measurement of the $^{12}$C($n,p$) and $^{12}$C($n,d$) reactions from n_TOF. The reliable analysis of these data must account for the challenging nature of the involved reactions, as they are affected by the multiple excited states in the daughter nuclei and characterized by the anisotropic angular distributions of the reaction products. The unabridged analysis procedure aims at the separate reconstruction of all relevant reaction parameters - the absolute cross section, the branching ratios and the angular distributions - from the integral number of the coincidental counts detected by the separate pairs of silicon strips. This procedure is tested under the specific conditions relevant for the $^{12}$C($n,p$) and $^{12}$C($n,d$) measurements from n_TOF, in order to assess its direct applicability to these experimental data. Based on the reached conclusions, the original method is adapted to a particular level of uncertainties in the input data.
71 - R.A. Soltz 2020
This article presents the motivation for developing a comprehensive modeling framework in which different models and parameter inputs can be compared and evaluated for a large range of jet-quenching observables measured in relativistic heavy-ion coll isions at RHIC and the LHC. The concept of a framework us discussed within the context of recent efforts by the JET Collaboration, the authors of JEWEL, and the JETSCAPE collaborations. The framework ingredients for each of these approaches is presented with a sample of important results from each. The role of advanced statistical tools in comparing models to data is also discussed, along with the need for a more detailed accounting of correlated errors in experimental results.
69 - Niseem Magdy 2017
A charge-sensitive in-event correlator is proposed and tested for its efficacy to detect and characterize charge separation associated with the Chiral Magnetic Effect (CME) in heavy ion collisions. Tests, performed with the aid of two reaction models , indicate discernible responses for background- and CME-driven charge separation, relative to the second- ($Psi_{2}$) and third-order ($Psi_{3}$) event planes, which could serve to identify the CME. The tests also indicate a degree of sensitivity which would enable robust characterization of the CME via Anomalous Viscous Fluid Dynamics (AVFD) model comparisons.
Modern coaxial and planar HPGe detectors allow a precise determination of the energies and trajectories of the impinging gamma-rays. This entails the location of the gamma interactions inside the crystal from the shape of the delivered signals. This paper reviews the state of the art of the analysis of the HPGe response function and proposes methods that lead to optimum signal decomposition. The generic matrix method allows fast location of the interactions even when the induced signals strongly overlap.